Back to Search Start Over

Predicting [177Lu]Lu-HA-DOTATATE kidney and tumor accumulation based on [68Ga]Ga-HA-DOTATATE diagnostic imaging using semi-physiological population pharmacokinetic modeling

Authors :
Siebinga, Hinke
de van der Veen, Berlinda J.
Beijnen, Jos H.
Stokkel, Marcel P. M.
Dorlo, Thomas P. C.
Huitema, Alwin D. R.
Hendrikx, Jeroen J. M. A.
Siebinga, Hinke
de van der Veen, Berlinda J.
Beijnen, Jos H.
Stokkel, Marcel P. M.
Dorlo, Thomas P. C.
Huitema, Alwin D. R.
Hendrikx, Jeroen J. M. A.
Publication Year :
2023

Abstract

Background Prediction of [177Lu]Lu-HA-DOTATATE kidney and tumor uptake based on diagnostic [68Ga]Ga-HA-DOTATATE imaging would be a crucial step for precision dosing of [177Lu]Lu-HA-DOTATATE. In this study, the population pharmacokinetic (PK) differences between [177Lu]Lu-HA-DOTATATE and [68Ga]Ga-HA-DOTATATE were assessed and subsequently [177Lu]Lu-HA-DOTATATE was predicted based on [68Ga]Ga-HA-DOTATATE imaging. Methods A semi-physiological nonlinear mixed-effects model was developed for [68Ga]Ga-HA-DOTATATE and [177Lu]Lu-HA-DOTATATE, including six compartments (representing blood, spleen, kidney, tumor lesions, other somatostatin receptor expressing organs and a lumped rest compartment). Model parameters were fixed based on a previously developed physiologically based pharmacokinetic model for [68Ga]Ga-HA-DOTATATE. For [177Lu]Lu-HA-DOTATATE, PK parameters were based on literature values or estimated based on scan data (four time points post-injection) from nine patients. Finally, individual [177Lu]Lu-HA-DOTATATE uptake into tumors and kidneys was predicted based on individual [68Ga]Ga-HA-DOTATATE scan data using Bayesian estimates. Predictions were evaluated compared to observed data using a relative prediction error (RPE) for both area under the curve (AUC) and absorbed dose. Lastly, to assess the predictive value of diagnostic imaging to predict therapeutic exposure, individual prediction RPEs (using Bayesian estimation) were compared to those from population predictions (using the population model). Results Population uptake rate parameters for spleen, kidney and tumors differed by a 0.29-fold (15% relative standard error (RSE)), 0.49-fold (15% RSE) and 1.43-fold (14% RSE), respectively, for [177Lu]Lu-HA-DOTATATE compared to [68Ga]Ga-HA-DOTATATE. Model predictions adequately described observed data in kidney and tumors for both peptides (based on visual inspection of goodness-of-fit plots). Individual predictions of tumor uptake were better (RPE AUC –40 to 28%) c

Details

Database :
OAIster
Notes :
application/pdf, English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1428123811
Document Type :
Electronic Resource
Full Text :
https://doi.org/10.1186.s40658-023-00565-4