Back to Search Start Over

Enabling ultra-high dose rate electron beams at a clinical linear accelerator for isocentric treatments

Authors :
Dal Bello, Riccardo
von der Grün, Jens
Fabiano, Silvia
Rudolf, Thomas
Saltybaeva, Natalia
S Stark, Luisa
Ahmed, Md
Bathula, Manohar
Kucuker Dogan, Serpil
McNeur, Joshua
Guckenberger, Matthias
Tanadini-Lang, Stephanie
Dal Bello, Riccardo
von der Grün, Jens
Fabiano, Silvia
Rudolf, Thomas
Saltybaeva, Natalia
S Stark, Luisa
Ahmed, Md
Bathula, Manohar
Kucuker Dogan, Serpil
McNeur, Joshua
Guckenberger, Matthias
Tanadini-Lang, Stephanie
Source :
Dal Bello, Riccardo; von der Grün, Jens; Fabiano, Silvia; Rudolf, Thomas; Saltybaeva, Natalia; S Stark, Luisa; Ahmed, Md; Bathula, Manohar; Kucuker Dogan, Serpil; McNeur, Joshua; Guckenberger, Matthias; Tanadini-Lang, Stephanie (2023). Enabling ultra-high dose rate electron beams at a clinical linear accelerator for isocentric treatments. Radiotherapy and Oncology, 187:109822.
Publication Year :
2023

Abstract

BACKGROUND AND PURPOSE Radiotherapy delivery with ultra-high dose rates (UHDR) has consistently produced normal tissue sparing while maintaining efficacy for tumour control in preclinical studies, known as the FLASH effect. Modified clinical electron linacs have been used for pre-clinical studies at reduced source-surface distance (SSD) and novel intra-operative devices are becoming available. In this context, we modified a clinical linac to deliver 16 MeV UHDR electron beams with an isocentric setup. MATERIALS AND METHODS The first Varian TrueBeam (SN 1001) was clinically operative between 2009-2022, it was then decommissioned and converted into a research platform. The 18 MeV electron beam was converted into the experimental 16 MeV UHDR. Modifications were performed by Varian and included a software patch, thinner scattering foil and beam tuning. The dose rate, beam characteristics and reproducibility were measured with electron applicators at SSD = 100 cm. RESULTS The dose per pulse at isocenter was up to 1.28 Gy/pulse, corresponding to average and instantaneous dose rates up to 256 Gy/s and 3⋅10$^{5}$ Gy/s, respectively. Beam characteristics were equivalent between 16 MeV UHDR and conventional for field sizes up to 10x10cm$^{2}$ and an overall beam reproducibility within ± 2.5% was measured. CONCLUSIONS We report on the first technical conversion of a Varian TrueBeam to produce 16 MeV UHDR electron beams. This research platform will allow isocenter experiments and deliveries with conventional setups up to field sizes of 10x10 cm$^{2}$ within a hospital environment, reducing the gap between preclinical and clinical electron FLASH investigations.

Details

Database :
OAIster
Journal :
Dal Bello, Riccardo; von der Grün, Jens; Fabiano, Silvia; Rudolf, Thomas; Saltybaeva, Natalia; S Stark, Luisa; Ahmed, Md; Bathula, Manohar; Kucuker Dogan, Serpil; McNeur, Joshua; Guckenberger, Matthias; Tanadini-Lang, Stephanie (2023). Enabling ultra-high dose rate electron beams at a clinical linear accelerator for isocentric treatments. Radiotherapy and Oncology, 187:109822.
Notes :
application/pdf, info:doi/10.5167/uzh-235111, English, English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1443053216
Document Type :
Electronic Resource