Back to Search
Start Over
Hemodynamic Failure Staging With Blood Oxygenation Level-Dependent Cerebrovascular Reactivity and Acetazolamide-Challenged ($^{15}$O-)H$_{2}$O-Positron Emission Tomography Across Individual Cerebrovascular Territories
- Source :
- Sebök, Martina; van der Wouden, Frank; Mader, Cäcilia; Pangalu, Athina; Treyer, Valerie; Fisher, Joseph Arnold; Mikulis, David John; Hüllner, Martin; Regli, Luca; Fierstra, Jorn; van Niftrik, Christiaan Hendrik Bas (2023). Hemodynamic Failure Staging With Blood Oxygenation Level-Dependent Cerebrovascular Reactivity and Acetazolamide-Challenged ($^{15}$O-)H$_{2}$O-Positron Emission Tomography Across Individual Cerebrovascular Territories. Journal of the American Heart Association, 12(24):e029491.
- Publication Year :
- 2023
-
Abstract
- BACKGROUND Staging of hemodynamic failure (HF) in symptomatic patients with cerebrovascular steno-occlusive disease is required to assess the risk of ischemic stroke. Since the gold standard positron emission tomography-based perfusion reserve is unsuitable as a routine clinical imaging tool, blood oxygenation level-dependent cerebrovascular reactivity (BOLD-CVR) with CO$_{2}$ is a promising surrogate imaging approach. We investigated the accuracy of standardized BOLD-CVR to classify the extent of HF. METHODS AND RESULTS Patients with symptomatic unilateral cerebrovascular steno-occlusive disease, who underwent both an acetazolamide challenge ($^{15}$O-)H$_{2}$O-positron emission tomography and BOLD-CVR examination, were included. HF staging of vascular territories was assessed using qualitative inspection of the positron emission tomography perfusion reserve images. The optimum BOLD-CVR cutoff points between HF stages 0-1-2 were determined by comparing the quantitative BOLD-CVR data to the qualitative ($^{15}$O-)H$_{2}$O-positron emission tomography classification using the 3-dimensional accuracy index to the randomly assigned training and test data sets with the following determination of a single cutoff for clinical application. In the 2-case scenario, classifying data points as HF 0 or 1-2 and HF 0-1 or 2, BOLD-CVR showed an accuracy of >0.7 for all vascular territories for HF 1 and HF 2 cutoff points. In particular, the middle cerebral artery territory had an accuracy of 0.79 for HF 1 and 0.83 for HF 2, whereas the anterior cerebral artery had an accuracy of 0.78 for HF 1 and 0.82 for HF 2. CONCLUSIONS Standardized and clinically accessible BOLD-CVR examinations harbor sufficient data to provide specific cerebrovascular reactivity cutoff points for HF staging across individual vascular territories in symptomatic patients with unilateral cerebrovascular steno-occlusive disease.
Details
- Database :
- OAIster
- Journal :
- Sebök, Martina; van der Wouden, Frank; Mader, Cäcilia; Pangalu, Athina; Treyer, Valerie; Fisher, Joseph Arnold; Mikulis, David John; Hüllner, Martin; Regli, Luca; Fierstra, Jorn; van Niftrik, Christiaan Hendrik Bas (2023). Hemodynamic Failure Staging With Blood Oxygenation Level-Dependent Cerebrovascular Reactivity and Acetazolamide-Challenged ($^{15}$O-)H$_{2}$O-Positron Emission Tomography Across Individual Cerebrovascular Territories. Journal of the American Heart Association, 12(24):e029491.
- Notes :
- application/pdf, info:doi/10.5167/uzh-252862, English, English
- Publication Type :
- Electronic Resource
- Accession number :
- edsoai.on1443055573
- Document Type :
- Electronic Resource