Back to Search
Start Over
Safety of pulsed field ablation in more than 17,000 patients with atrial fibrillation in the MANIFEST-17K study
- Source :
- Ekanem , E , Neuzil , P , Reichlin , T , Kautzner , J , van der Voort , P , Jais , P , Chierchia , G B , Bulava , A , Blaauw , Y , Skala , T , Fiala , M , Duytschaever , M , Szeplaki , G , Schmidt , B , Massoullie , G , Neven , K , Thomas , O , Vijgen , J , Gandjbakhch , E , Scherr , D , Johannessen , A , Keane , D , Boveda , S , Maury , P , García-Bolao , I , Anic , A , Hansen , P S , Raczka , F , Lepillier , A , Guyomar , Y , Gupta , D , Van Opstal , J , Defaye , P , Sticherling , C , Sommer , P , Kucera , P , Osca , J , Tabrizi , F , Roux , A , Gramlich , M , Bianchi , S , Adragão , P , Solimene , F , Tondo , C , Russo , A D , Schreieck , J , Luik , A , Rana , O , Frommeyer , G , Anselme , F , Kreis , I , Rosso , R , Metzner , A , Geller , L , Baldinger , S H , Ferrero , A , Willems , S , Goette , A , Mellor , G , Mathew , S , Szumowski , L , Tilz , R , Iacopino , S , Jacobsen , P K , George , A , Osmancik , P , Spitzer , S , Balasubramaniam , R , Parwani , A S , Deneke , T , Glowniak , A , Rossillo , A , Pürerfellner , H , Duncker , D , Reil , P , Arentz , T , Steven , D , Olalla , J J , de Jong , J S S G , Wakili , R , Abbey , S , Timo , G , Asso , A , Wong , T , Pierre , B , Ewertsen , N C , Bergau , L , Lozano-Granero , C , Rivero , M , Breitenstein , A , Inkovaara , J , Fareh , S , Latcu , D G , Linz , D , Müller , P , Ramos-Maqueda , J , Beiert , T , Themistoclakis , S , Meininghaus , D G , Stix , G , Tzeis , S , Baran , J , Almroth , H , Munoz , D R , de Sousa , J , Efremidis , M , Balsam , P , Petru , J , Küffer , T , Peichl , P , Dekker , L , Della Rocca , D G , Moravec , O , Funasako , M , Knecht , S , Jauvert , G , Chun , J , Eschalier , R , Füting , A , Zhao , A , Koopman , P , Laredo , M , Manninger , M , Hansen , J , O’Hare , D , Rollin , A , Jurisic , Z , Fink , T , Chaumont , C , Rillig , A , Gunawerdene , M , Martin , C , Kirstein , B , Nentwich , K , Lehrmann , H , Sultan , A , Bohnen , J , Turagam , M K & Reddy , V Y 2024 , ' Safety of pulsed f
- Publication Year :
- 2024
-
Abstract
- Pulsed field ablation (PFA) is an emerging technology for the treatment of atrial fibrillation (AF), for which pre-clinical and early-stage clinical data are suggestive of some degree of preferentiality to myocardial tissue ablation without damage to adjacent structures. Here in the MANIFEST-17K study we assessed the safety of PFA by studying the post-approval use of this treatment modality. Of the 116 centers performing post-approval PFA with a pentaspline catheter, data were received from 106 centers (91.4% participation) regarding 17,642 patients undergoing PFA (mean age 64, 34.7% female, 57.8% paroxysmal AF and 35.2% persistent AF). No esophageal complications, pulmonary vein stenosis or persistent phrenic palsy was reported (transient palsy was reported in 0.06% of patients; 11 of 17,642). Major complications, reported for ~1% of patients (173 of 17,642), were pericardial tamponade (0.36%; 63 of 17,642) and vascular events (0.30%; 53 of 17,642). Stroke was rare (0.12%; 22 of 17,642) and death was even rarer (0.03%; 5 of 17,642). Unexpected complications of PFA were coronary arterial spasm in 0.14% of patients (25 of 17,642) and hemolysis-related acute renal failure necessitating hemodialysis in 0.03% of patients (5 of 17,642). Taken together, these data indicate that PFA demonstrates a favorable safety profile by avoiding much of the collateral damage seen with conventional thermal ablation. PFA has the potential to be transformative for the management of patients with AF.
Details
- Database :
- OAIster
- Journal :
- Ekanem , E , Neuzil , P , Reichlin , T , Kautzner , J , van der Voort , P , Jais , P , Chierchia , G B , Bulava , A , Blaauw , Y , Skala , T , Fiala , M , Duytschaever , M , Szeplaki , G , Schmidt , B , Massoullie , G , Neven , K , Thomas , O , Vijgen , J , Gandjbakhch , E , Scherr , D , Johannessen , A , Keane , D , Boveda , S , Maury , P , García-Bolao , I , Anic , A , Hansen , P S , Raczka , F , Lepillier , A , Guyomar , Y , Gupta , D , Van Opstal , J , Defaye , P , Sticherling , C , Sommer , P , Kucera , P , Osca , J , Tabrizi , F , Roux , A , Gramlich , M , Bianchi , S , Adragão , P , Solimene , F , Tondo , C , Russo , A D , Schreieck , J , Luik , A , Rana , O , Frommeyer , G , Anselme , F , Kreis , I , Rosso , R , Metzner , A , Geller , L , Baldinger , S H , Ferrero , A , Willems , S , Goette , A , Mellor , G , Mathew , S , Szumowski , L , Tilz , R , Iacopino , S , Jacobsen , P K , George , A , Osmancik , P , Spitzer , S , Balasubramaniam , R , Parwani , A S , Deneke , T , Glowniak , A , Rossillo , A , Pürerfellner , H , Duncker , D , Reil , P , Arentz , T , Steven , D , Olalla , J J , de Jong , J S S G , Wakili , R , Abbey , S , Timo , G , Asso , A , Wong , T , Pierre , B , Ewertsen , N C , Bergau , L , Lozano-Granero , C , Rivero , M , Breitenstein , A , Inkovaara , J , Fareh , S , Latcu , D G , Linz , D , Müller , P , Ramos-Maqueda , J , Beiert , T , Themistoclakis , S , Meininghaus , D G , Stix , G , Tzeis , S , Baran , J , Almroth , H , Munoz , D R , de Sousa , J , Efremidis , M , Balsam , P , Petru , J , Küffer , T , Peichl , P , Dekker , L , Della Rocca , D G , Moravec , O , Funasako , M , Knecht , S , Jauvert , G , Chun , J , Eschalier , R , Füting , A , Zhao , A , Koopman , P , Laredo , M , Manninger , M , Hansen , J , O’Hare , D , Rollin , A , Jurisic , Z , Fink , T , Chaumont , C , Rillig , A , Gunawerdene , M , Martin , C , Kirstein , B , Nentwich , K , Lehrmann , H , Sultan , A , Bohnen , J , Turagam , M K & Reddy , V Y 2024 , ' Safety of pulsed f
- Notes :
- application/pdf, English
- Publication Type :
- Electronic Resource
- Accession number :
- edsoai.on1479135624
- Document Type :
- Electronic Resource