Back to Search Start Over

Study on the design of short blade offset for the long and short blade runner of 1000 MW hydraulic turbine units

Authors :
Universitat Politècnica de Catalunya. Doctorat en Enginyeria Mecànica, Fluids i Aeronàutica
Universitat Politècnica de Catalunya. Departament de Mecànica de Fluids
Universitat Politècnica de Catalunya. CDIF - Centre de Diagnòstic Industrial i Fluidodinàmica
Lu, Yonggang
Zhang, Zequan
Chen, Hao
Liu, Kui
Huang, Xingxing
Li, Honghui
Wang, Zhengwei
Presas Batlló, Alexandre
Universitat Politècnica de Catalunya. Doctorat en Enginyeria Mecànica, Fluids i Aeronàutica
Universitat Politècnica de Catalunya. Departament de Mecànica de Fluids
Universitat Politècnica de Catalunya. CDIF - Centre de Diagnòstic Industrial i Fluidodinàmica
Lu, Yonggang
Zhang, Zequan
Chen, Hao
Liu, Kui
Huang, Xingxing
Li, Honghui
Wang, Zhengwei
Presas Batlló, Alexandre
Publication Year :
2024

Abstract

For such complex rotating machinery as hydraulic turbine, the hydraulic operation characteristics of the hydraulic turbine unit are significantly impacted by the short blade of the runner used as the splitter blade. To find the optimum position of the short blade, the study object is the 1000 MW hydraulic turbine, selects three circumferential offset positions of the short blade for numerical simulation calculation, obtains the runner flow pattern at different offsets, and explores the impact on the short blade offset on the vortex and pressure pulsation in the runner. The results show that the counterclockwise offset of the short blade will improve the flow pattern of the runner, reduce the scale of vortex in the runner and enhance the efficiency of the hydraulic turbine. The counterclockwise offset will increase the interference while decreasing the pressure pulsation in the vaneless region, at the runner's inlet, and downstream of the short blade. When the offset d=0.6, the peak-valley difference of pressure fluctuation in the vaneless zone is the smallest, accounting for only 1.38 % of the rated head. The main frequency of the vaneless zone gradually changes from 15fn to 30fn, and the main frequency of the runner inlet and the short blade downstream is 24fn. Due to the different weakening effects of short blades on the interference, low-frequency pulsation components of 4fn and 8fn appear.<br />This study was supported by National Natural Science Foundation of China (51876099), Natural Science Foundation of Jiangsu Province (BK20210771), China Postdoctoral Science Foundation Funded Project (2021M701847 & 2022M711768).<br />Peer Reviewed<br />Postprint (published version)