Back to Search Start Over

Prospective evaluation of MRI artefacts following breast conserving surgery and sentinel lymph node dissection with the magnetic technique

Authors :
Jazrawi, Allan
Pantiora, Eirini
Abdsaleh, Shahin
Lian NG, Chin
Zouzos, Athanasios
Gagliardi, Tanja
Wärnberg, Fredrik
Eriksson, Staffan
Karakatsanis, Andreas
Jazrawi, Allan
Pantiora, Eirini
Abdsaleh, Shahin
Lian NG, Chin
Zouzos, Athanasios
Gagliardi, Tanja
Wärnberg, Fredrik
Eriksson, Staffan
Karakatsanis, Andreas
Publication Year :
2025

Abstract

Introduction Superparamagnetic Iron Oxide (SPIO) nanoparticles serve as a promising tracer for sentinel lymph node (SLN) detection in breast cancer. Concerns exist regarding artefacts on postoperative Magnetic Resonance Imaging (MRI), especially following breast conservation (BCS). Materials and methods In this prospective observational study, 97 women with DCIS or invasive breast cancer underwent BCS and SLN detection with peritumoral SPIO injection administered up to four weeks before surgery. Postoperatively, patients were followed with MRI and mammograms, and imaging outcomes were evaluated by four, independent breast radiologists, blinded to clinical data, using a predefined, standardized questionnaire. Results In 97 patients included, there was inter-rater discordance in the prevalence of “any artefact” (range: 24.1–74.4 %; weighted average: 32.4 %) and “SPIO specific artefact” (range: 12.0–49.4 %; weighted average: 20.9 %). The median area of “any artefact” was 9.24 cm2 (iqr 4.72, 15.50) and SPIO specific artefact 9.88 (iqr 5.32, 15.5). Likert scores indicated higher difficulty interpreting MRI if artefacts were present (OR: 2.295, 95 % CI 1.028, 5.123; p = 0.043), but this was reduced if intravenous contrast was administered (OR: 0.177, 95 % CI 0.091, 0.342; p < 0.001). Multivariable analysis identified free-hand SPIO administration as a risk factor (OR 8.929, 95 % CI 2.849, 27.778; p < 0.001). All six patients with local recurrence were successfully diagnosed on MRI by all raters. Conclusion This prospective cohort study suggests that a targeted peritumoral SPIO injection can result in the removal of SPIO during lumpectomy and address the concerns for artefacts on postoperative MRI follow-up, in the selected patients that MRI may be warranted.<br />De två sista författarna delar sistaförfattarskapet

Details

Database :
OAIster
Notes :
application/pdf, English
Publication Type :
Electronic Resource
Accession number :
edsoai.on1481650090
Document Type :
Electronic Resource
Full Text :
https://doi.org/10.1016.j.ejso.2024.109368