1. Initial Experience of Implementing a Pre-treatment Dry Run for HyperArc Stereotactic Radiosurgery Treatments With Optical Surface Imaging for Intra-fraction Motion Monitoring.
- Author
-
Wright EA, Becker N, Mou B, and Hyde D
- Abstract
Linac-based stereotactic radiosurgery (SRS) with planning target volume (PTV) margins <1 mm has become increasingly common in recent years. Optical surface imaging for surface-guided radiation therapy (SGRT) is often used for intra-fraction motion monitoring during these treatments to facilitate the use of a smaller PTV margin by providing real-time quantitative patient positioning information. However, rotating the couch introduces errors to SGRT-reported translations and rotations that can be problematic for SRS treatments with non-coplanar arcs and very small PTV margins. This work presents a novel approach for decreasing the magnitude of these errors by performing a pre-treatment dry run and capturing reference surfaces with the SGRT system at each couch angle included in the treatment plan. Time from cone beam computed tomography (CBCT) to treatment initiation and total treatment session time were reviewed for 30 single-fraction brain SRS cases treated using this technique to determine the effect of including the dry run on treatment session times. Out of the 30 cases treated between April 2023 and January 2024, 23 treatments required only a single CBCT prior to treatment, with no additional mid-treatment imaging required to verify patient positioning after motion. The median time between CBCT and treatment initiation was 7.98 minutes (interquartile range (IQR) = 7.28 to 8.93 minutes). The median time from CBCT to treatment completion was 15.43 minutes (IQR = 13.67 to 21.97 minutes). In the six patients that required one additional CBCT, the treatment session times ranged from 24.32 to 32.83 minutes. There was one patient who required three mid-treatment CBCTs, and the treatment session time was 67.87 minutes. Incorporating the pre-treatment dry run with the acquisition of reference surfaces at each treatment angle decreased errors in SGRT-reported translations and rotations associated with couch rotation without significantly increasing treatment session times., Competing Interests: Human subjects: Consent for treatment and open access publication was obtained or waived by all participants in this study. BC Cancer Research Ethics Board issued approval (exempt). This study met our institutional definition of quality improvement and research ethics board approval was not required. Animal subjects: All authors have confirmed that this study did not involve animal subjects or tissue. Conflicts of interest: In compliance with the ICMJE uniform disclosure form, all authors declare the following: Payment/services info: All authors have declared that no financial support was received from any organization for the submitted work. Financial relationships: All authors have declared that they have no financial relationships at present or within the previous three years with any organizations that might have an interest in the submitted work. Other relationships: All authors have declared that there are no other relationships or activities that could appear to have influenced the submitted work., (Copyright © 2024, Wright et al.)
- Published
- 2024
- Full Text
- View/download PDF