1. Remote monitoring of cardiac implantable electronic devices using smart device interface versus radiofrequency-based interface: A systematic review.
- Author
-
Vern Hsen Tan, Hui Xin See Tow, Khi Yung Fong, Yue Wang, Colin Yeo, Chi Keong Ching, and Toon Wei Lim
- Subjects
MEDICAL information storage & retrieval systems ,PATIENT compliance ,SMARTPHONES ,DESCRIPTIVE statistics ,ASSISTIVE technology ,SYSTEMATIC reviews ,MEDLINE ,IMPLANTABLE cardioverter-defibrillators ,BIOTELEMETRY ,MEDICAL databases ,CARDIAC pacemakers ,ONLINE information services ,CONFIDENCE intervals ,TIME - Abstract
Background: Guidelines recommended remote monitoring (RM) in managing patients with Cardiac Implantable Electronic Devices. In recent years, smart device (phone or tablet) monitoring-based RM (SM-RM) was introduced. This study aims to systematically review SM-RM versus bedside monitor RM (BM-RM) using radiofrequency in terms of compliance, connectivity, and episode transmission time. Methods: We conducted a systematic review, searching three international databases from inception until July 2023 for studies comparing SM-RM (intervention group) versus BM-RM (control group). Results: Two matched studies (21 978 patients) were retrieved (SM-RM arm: 9642 patients, BM-RM arm: 12 336 patients). There is significantly higher compliance among SM-RM patients compared with BM-RM patients in both pacemaker and defibrillator patients. Manyam et al. found that more SM-RM patients than BM-RM patients transmitted at least once (98.1% vs. 94.3%, p < .001), and Tarakji et al. showed that SM-RM patients have higher success rates of scheduled transmissions than traditional BM-RM methods (SM-RM: 94.6%, pacemaker manual: 56.3%, pacemaker wireless: 77.0%, defibrillator wireless: 87.1%). There were higher enrolment rates, completed scheduled and patient-initiated transmissions, shorter episode transmission time, and higher connectivity among SM-RM patients compared to BM-RM patients. Younger patients (aged <75) had more patient-initiated transmissions, and a higher proportion had ≥10 transmissions compared with older patients (aged ≥75) in both SM-RM and BM-RM groups. Conclusion: SM-RM is a step in the right direction, with good compliance, connectivity, and shorter episode transmission time, empowering patients to be in control of their health. Further research on cost-effectiveness and long-term clinical outcomes can be carried out. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF