1. Slice positioning in phase-contrast MRI impacts aortic stenosis assessment.
- Author
-
Troger F, Tiller C, Reindl M, Lechner I, Holzknecht M, Pamminger M, Poskaite P, Kremser C, Ulmer H, Gizewski ER, Bauer A, Reinstadler S, Metzler B, Klug G, and Mayr A
- Subjects
- Humans, Magnetic Resonance Imaging, Echocardiography, Stroke Volume, Aortic Valve diagnostic imaging, Aortic Valve pathology, Aortic Valve Stenosis diagnostic imaging, Aortic Valve Stenosis pathology
- Abstract
Aims: To determine the phase-contrast cardiovascular magnetic resonance imaging (PC-CMR) slice-position above aortic leaflet-attachment-plane (LAP) that provides flow-velocity, -volume and aortic valve area (AVA) measurements with best agreement to invasive and echocardiographic measurements in aortic stenosis (AS)., Methods and Results: Fifty-five patients with moderate/severe AS underwent cardiac catheterization, transthoracic echocardiography (TTE) and CMR. Overall, 171 image-planes parallel to LAP were measured via PC-CMR between 22 mm below and 24 mm above LAP. AVA via PC-CMR was calculated as flow-volume divided by peak-velocity during systole. Stroke volume (SV) and AVA were compared to volumetric SV and invasive AVA via the Gorlin-formula, respectively. Above LAP, SV by PC-CMR showed no significant dependence on image-plane-position and correlated strongly with volumetry (rho: 0.633, p < 0.001, marginal-mean-difference (MMD): 1 ml, 95 % confidence-interval (CI): -4 to 6). AVA assessed in image-planes 0-10 mm above LAP differed significantly from invasive measurement (MMD: -0.14 cm
2 , 95 %CI: 0.08-0.21). In contrast, AVA-values by PC-CMR measured 10-20 mm above LAP showed good agreement with invasive determination without significant MMD (0.003 cm2 , 95 %CI: -0.09 to 0.09). Within these measurements, a plane 15 mm above LAP resulted in the lowest bias (MMD: 0.02 cm2 , 95 %CI:-0.29 to 0.33). SV and AVA via TTE correlated moderately with volumetry (rho: 0.461, p < 0.001; bias: 15 ml, p < 0.001) and cardiac catheterization (rho: 0.486, p < 0.001, bias: -0.13 cm2 , p < 0.001), respectively., Conclusion: PC-CMR measurements at 0-10 mm above LAP should be avoided due to significant AVA-overestimation compared to invasive determination. AVA-assessment by PC-CMR between 10 and 20 mm above LAP did not differ from invasive measurements, with the lowest intermethodical bias measured 15 mm above LAP., Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper., (Copyright © 2023. Published by Elsevier B.V.)- Published
- 2023
- Full Text
- View/download PDF