30 results on '"Anna Koziol"'
Search Results
2. A Single-Electron Injection Device for CMOS Charge Qubits Implemented in 22-nm FD-SOI
- Author
-
R. Bogdan Staszewski, Ali Esmailiyan, Mike Asker, Andrii Sokolov, Panagiotis Giounanlis, Dennis Andrade-Miceli, Elena Blokhina, Teerachot Siriburanon, Imran Bashir, Eugene Koskin, Hongying Wang, Dirk Leipold, and Anna Koziol
- Subjects
Physics ,Charge qubit ,business.industry ,Silicon on insulator ,02 engineering and technology ,021001 nanoscience & nanotechnology ,01 natural sciences ,CMOS ,Quantum dot ,Logic gate ,Qubit ,0103 physical sciences ,Quantum operation ,Optoelectronics ,Electrical and Electronic Engineering ,010306 general physics ,0210 nano-technology ,business ,Quantum computer - Abstract
This letter presents a single-electron injection device for position-based charge qubit structures implemented in 22-nm fully depleted silicon-on-insulator CMOS. Quantum dots are implemented in local well areas separated by tunnel barriers controlled by gate terminals overlapping with a thin 5-nm undoped silicon film. Interface of the quantum structure with classical electronic circuitry is provided with single-electron transistors that feature doped wells on the classic side. A small $0.7\times 0.4\,\,\mu \text{m}^{2}$ elementary quantum core is co-located with control circuitry inside the quantum operation cell which is operating at 3.5 K and a 2-GHz clock frequency. With this apparatus, we demonstrate a single-electron injection into a quantum dot.
- Published
- 2020
- Full Text
- View/download PDF
3. A Fully Integrated DAC for CMOS Position-Based Charge Qubits with Single-Electron Detector Loopback Testing
- Author
-
Eugene Koskin, Imran Bashir, R. Bogdan Staszewski, Elena Blokhina, Dirk Leipold, Kai Xu, Anna Koziol, Hongying Wang, Ali Esmailiyan, and Mike Asker
- Subjects
010302 applied physics ,Physics ,Charge qubit ,business.industry ,020208 electrical & electronic engineering ,Detector ,Charge (physics) ,02 engineering and technology ,01 natural sciences ,Noise (electronics) ,CMOS ,Logic gate ,Qubit ,0103 physical sciences ,0202 electrical engineering, electronic engineering, information engineering ,Optoelectronics ,Electrical and Electronic Engineering ,business ,Quantum computer - Abstract
This letter presents a fully integrated interface circuitry with a position-based charge qubit structure implemented in 22-nm FDSOI CMOS. The quantum structure is controlled by a tiny capacitive DAC (CDAC) that occupies $3.5\times 45\,\,\mu \text{m}^{2}$ and consumes 0.27mW running at a 2-GHz system clock. The state of the quantum structure is measured by a single-electron detector that consumes 1mW (including its output driver) with an area of $40\times 25\,\,\mu \text{m}^{2}$ . The low power and miniaturized layout of these circuits pave the way for integration in a large quantum core with thousands of qubits, which is a necessity for practical quantum computers. The CDAC output noise of 12 $\mu \text{V}$ -rms is estimated through mathematical analysis while the ≤ 0.225mV-rms input referred noise of the detector is verified by measurements at 3.4 K. The functionality of the system and performance of the CDAC are verified in a loopback mode with the detector sensing the CDAC-induced electron tunneling from the floating diffusion node into the quantum structure.
- Published
- 2020
- Full Text
- View/download PDF
4. Local variability in snow concentrations of chlorinated persistent organic pollutants as a source of large uncertainty in interpreting spatial patterns at all scales
- Author
-
Filip Pawlak, Krystyna Anna Koziol, Klaudia Kosek, and Zaneta Polkowska
- Subjects
Persistent Organic Pollutants ,Environmental Engineering ,Snow ,Hydrocarbons, Chlorinated ,Uncertainty ,Management, Monitoring, Policy and Law ,Pesticides ,Pollution ,Waste Management and Disposal ,Polychlorinated Biphenyls ,Water Science and Technology ,Environmental Monitoring - Abstract
Single point sampling, a widespread practice in snow studies in remote areas, due to logistical constraints, can present an unquantified error to the final study results. The low concentrations of studied chemicals, such as chlorinated persistent organic pollutants, contribute to the uncertainty. We conducted a field experiment in the Arctic to estimate the error stemming from differences in the composition of snow at short distances (1-3 m), including 13 single organochlorine pesticides and 6 polychlorinated biphenyls, thus providing the most detailed published dataset on the subject. We contrasted this variability with the uncertainty at larger spatial scales, both within one valley (regional scale, this study) and as described in the worldwide literature. The range of values for the coefficient of variation for local samples was 20-58% for single organochlorine pesticides (OCPs) and 33-54% for polychlorinated biphenyls (PCBs), and for regional samples it was 21-69% for OCPs and 65-93% for PCBs. We suggest that, to observe the actual changes in the concentration of selected compounds in snow, they should vary at the level of 40-60%, depending on the compound in question. The uncertainty margin remains much smaller than the current discrepancy between observation data and atmospheric deposition models considering snow, deeming field data on snow concentrations a useful ground-truthing dataset. However, field observations on spatial differences at all scales need to be interpreted with caution, and the dataset provided here on the local sampling uncertainty helps define the margins of such interpretations.
- Published
- 2021
5. Solar Energy Healing Called Elle Ayat
- Author
-
Anna Koziol
- Subjects
Physics ,business.industry ,Solar energy ,business ,Engineering physics - Abstract
Ayat is a system of self-improvement of health and self-consciousness, which was proposed by Abdullayev Farkhat Muhamedovich more than 20 years ago and today, is used by many people all over the world. It helps thousands to regain health and live normal healthy and happy life.
- Published
- 2020
- Full Text
- View/download PDF
6. Scalable control systems for vertex detector utilizing single photon counting readout
- Author
-
Anna Koziol
- Subjects
Instrumentation ,Mathematical Physics - Abstract
I present the design of two vertex detector systems for proton particle trajectory tracking based on multiple layers of single photon counting hybrid pixel area detectors. The detector used in both systems is UFXC, which is a matrix of 128 × 256 pixels with silicon sensor. The first system enables proton transition registration with the speed of up to 50 kfps. The second system is a portable device with large detection area.
- Published
- 2022
- Full Text
- View/download PDF
7. RF Clock Distribution System for a Scalable Quantum Processor in 22-nm FDSOI Operating at 3.8 K Cryogenic Temperature
- Author
-
Elena Blokhina, Anna Koziol, Dirk Leipold, Imran Bashir, Dennis A. Miceli, Panagiotis Giounanlis, Teerachot Siriburanon, Hongying Wang, R. Bogdan Staszewski, Ali Esmailiyan, and Mike Asker
- Subjects
Coupling ,Physics ,Charge qubit ,Coaxial cable ,business.industry ,Electrical engineering ,Port (circuit theory) ,Hardware_PERFORMANCEANDRELIABILITY ,01 natural sciences ,Signal ,010305 fluids & plasmas ,law.invention ,law ,0103 physical sciences ,Hardware_INTEGRATEDCIRCUITS ,Path loss ,010306 general physics ,business ,Jitter ,Quantum computer - Abstract
We present an RF clock distribution system for a fully integrated and scalable quantum processor core operating at 3.8 K. An external 2.4 GHz signal is guided from the generator to the flip-chip package IC through a cryogenic coaxial cable. The choice of coaxial cable and the clock routing design on the PCB and IC, minimizes path loss and coupling to the supplies, the I/O signals, and more importantly the sensitive quantum core. The clock integrity up to the quantum core is maintained and verified by the jitter measurement of 0.8 ps from a test port while all circuitry within the cryo-cooler operates within the thermal load specification of 1.5 W.
- Published
- 2020
- Full Text
- View/download PDF
8. Polymorphism and Isostructurality of the Series of 3-(4,5-Diaryl-4H-1,2,4-triazole-3-yl)propenoic Acid Derivatives
- Author
-
Renata Paprocka, Katarzyna Jarzembska, Anna Koziol, Beata Modzelewska, Bożena Modzelewska-Banachiewicz, and Liliana Mazur
- Subjects
Hydrogen bond ,Stereochemistry ,1,2,4-Triazole ,02 engineering and technology ,General Chemistry ,Crystal structure ,Interaction energy ,010402 general chemistry ,021001 nanoscience & nanotechnology ,Condensed Matter Physics ,01 natural sciences ,0104 chemical sciences ,chemistry.chemical_compound ,Polymorphism (materials science) ,chemistry ,Intramolecular force ,Alkane stereochemistry ,Anhydrous ,General Materials Science ,0210 nano-technology - Abstract
Polymorphism of four biologically active 3-(4,5-diaryl-4H-1,2,4-triazole-3-yl)propenoic acid derivatives has been investigated. Traditional solution-based solid-state forms screening revealed three anhydrous forms of 3-[4-phenyl-5-(2-pyridyl)-4H-1,2,4-triazole-3-yl]propenoic acid. Noteworthy, two pairs of concomitant polymorphs were detected for this system. Two other compounds were found to be dimorphic. The molecular and crystal structures of all obtained crystal forms were established by single-crystal X-ray diffraction. The resulting crystal structures were analyzed in terms of molecular conformation, intermolecular interaction patterns, and crystal packing motifs. The experimental studies were supported by extended lattice and interaction energy calculations. It was found that the carboxylic group adopts the anti conformation in all studied forms and is involved in the intramolecular O–H···Ntriazole hydrogen bonding. In consequence, the association modes are dominated by the weak C–H···O, C–H···N hyd...
- Published
- 2017
- Full Text
- View/download PDF
9. Interlayer exchange coupling, dipolar coupling and magnetoresistance in Fe/MgO/Fe trilayers with a subnanometer MgO barrier
- Author
-
Sławomir Ziętek, Witold Skowroński, Piotr Rzeszut, Marek Frankowski, Anna Koziol-Rachwal, K. Matlak, Tomasz Stobiecki, Jakub Chęciński, Józef Korecki, M. Ślęzak, and T. Ślęzak
- Subjects
010302 applied physics ,Materials science ,Kerr effect ,Condensed matter physics ,Magnetoresistance ,Magnetism ,02 engineering and technology ,Dielectric ,021001 nanoscience & nanotechnology ,Condensed Matter Physics ,Epitaxy ,01 natural sciences ,Electronic, Optical and Magnetic Materials ,Nuclear magnetic resonance ,0103 physical sciences ,Antiferromagnetism ,0210 nano-technology ,Magnetic dipole–dipole interaction ,Molecular beam epitaxy - Abstract
Fe/MgO/Fe trilayers with a subnanometer MgO tunnel barrier were grown by molecular beam epitaxy. Longitudinal magnetooptic Kerr effect measurements confirmed the existence of the antiferromagnetic interlayer exchange coupling (IEC) between the Fe layers for 2 A
- Published
- 2017
- Full Text
- View/download PDF
10. First pump-probe-probe hard X-ray diffraction experiments with a 2D hybrid pixel detector developed at the SOLEIL synchrotron
- Author
-
Pawel Grybos, F. Orsini, Piotr Maj, Amélie Jarnac, Arkadiusz Dawiec, Arafat Noureddine, Brahim Kanouté, Claire Laulhé, Anna Koziol, Claude Menneglier, Jerome Bisou, Yves Marie Abiven, Pierre Fertey, Fabien Legrand, Gauthier Thibaux, Florent Langlois, and Diana Bachiller-Perea
- Subjects
Diffraction ,0303 health sciences ,Nuclear and High Energy Physics ,Radiation ,Materials science ,Pixel ,010308 nuclear & particles physics ,business.industry ,030303 biophysics ,Detector ,Chip ,01 natural sciences ,Synchrotron ,Photon counting ,law.invention ,03 medical and health sciences ,Optics ,Data acquisition ,Beamline ,law ,0103 physical sciences ,business ,Instrumentation - Abstract
A new photon-counting camera based on hybrid pixel technology has been developed at the SOLEIL synchrotron, making it possible to implement pump–probe–probe hard X-ray diffraction experiments for the first time. This application relies on two specific advantages of the UFXC32k readout chip, namely its high frame rate (50 kHz) and its high linear count rate (2.6 × 106 photons s−1 pixel−1). The project involved the conception and realization of the chips and detector carrier board, the data acquisition system, the server with its specific software, as well as the mechanical and cooling systems. This article reports on in-laboratory validation tests of the new detector, as well as on tests performed at the CRISTAL beamline within the targeted experimental conditions. A benchmark experiment was successfully performed, showing the advantages of the pump–probe–probe scheme in correcting for drifts of the experimental conditions.
- Published
- 2019
11. 1.2 Mfps standalone X-ray detector for Time-Resolved Experiments
- Author
-
Piotr Maj, Anna Koziol, D. Gorni, P. Dudek, Qingteng Zhang, and Piotr Otfinowski
- Subjects
Ethernet ,010308 nuclear & particles physics ,Computer science ,business.industry ,Detector ,Advanced Photon Source ,Frame rate ,01 natural sciences ,030218 nuclear medicine & medical imaging ,03 medical and health sciences ,0302 clinical medicine ,Data acquisition ,0103 physical sciences ,Transceiver ,business ,Instrumentation ,Mathematical Physics ,Computer hardware ,Burst mode (computing) ,Data compression - Abstract
We present a standalone and autonomous X-ray detector capable of operation with the speed of up to1.2 Mfps. The detector utilizes UFXC32k hybrid pixel detectors for sensing X-rays, Spartan-6 LX45 FPGA placed in commercially available sbRIO 9628 controller for data acquisition and processing including a compression with zero-suppression algorithm. A Linux-RT system working on the 400 MHz Dual-Core CPU is used for FPGA control and data streaming to the higher-level system over 1 Gbps Ethernet connection. 1.2 M frames per second is achieved in so-called burst mode of operation while in zerodead-time mode 70 kfps is possible. Due to efficient data compression in FPGA there's no need of using high-speed transceivers and Frame-Grabber cards on the data server side and the detector can stream the data infinitely over standard 1 Gbps network connection. Operation modes were tested at Advanced Photon Source Synchrotron at Argonne National Laboratory.
- Published
- 2020
- Full Text
- View/download PDF
12. High rate proton detection with single photon counting hybrid pixel detector
- Author
-
Si Xie, Robert Szczygiel, Mohd Meraj Hussain, Artur Apresyan, Pawel Grybos, Anna Koziol, Piotr Maj, and Ryan Heller
- Subjects
0301 basic medicine ,Physics ,030103 biophysics ,Nuclear and High Energy Physics ,Photon ,Pixel ,Proton ,Physics::Instrumentation and Detectors ,010308 nuclear & particles physics ,Firmware ,business.industry ,Detector ,computer.software_genre ,Tracking (particle physics) ,01 natural sciences ,Photon counting ,03 medical and health sciences ,Optics ,Data acquisition ,0103 physical sciences ,business ,Instrumentation ,computer - Abstract
We present the design and measurements of a proton detection system built using a single photon counting hybrid pixel array detector. The system uses the UFXC detector designed for operating with very high photon fluxes. We demonstrate, that with appropriately modified data acquisition firmware, the UFXC detector is capable of operating in the frame-triggered zero dead-time mode, which captures every frame containing desired information, at a rate of up to 50 kfps. The detector consists of a 128 x 256 matrix of square-shaped pixels with a pitch of 75 μ m , which makes it suitable for particle tracking applications in test beam environments. We estimate the position resolution achieved with a single layer of the UFXC detector to be around 40 μ m .
- Published
- 2020
- Full Text
- View/download PDF
13. Sub-microsecond-resolved multi-speckle X-ray photon correlation spectroscopy with a pixel array detector
- Author
-
Robert Szczygiel, Eric M. Dufresne, Alec Sandy, Piotr Maj, Pawel Grybos, Suresh Narayanan, Qingteng Zhang, Anna Koziol, and Mark Sutton
- Subjects
0301 basic medicine ,Physics ,030103 biophysics ,Nuclear and High Energy Physics ,Radiation ,Photon ,business.industry ,Dynamic range ,Detector ,01 natural sciences ,03 medical and health sciences ,Speckle pattern ,Microsecond ,Data acquisition ,Optics ,0103 physical sciences ,Wide dynamic range ,010306 general physics ,business ,Instrumentation ,Burst mode (computing) - Abstract
Small-angle X-ray photon correlation spectroscopy (XPCS) measurements spanning delay times from 826 ns to 52.8 s were performed using a photon-counting pixel array detector with a dynamic range of 0–3 (2 bits). Fine resolution and a wide dynamic range of time scales was achieved by combining two modes of operation of the detector: (i) continuous mode, where data acquisition and data readout are performed in parallel with a frame acquisition time of 19.36 µs, and (ii) burst mode, where 12 frames are acquired with frame integration times of either 2.56 µs frame−1or 826 ns frame−1followed by 3.49 ms or 1.16 ms, respectively, for readout. The applicability of the detector for performing multi-speckle XPCS was demonstrated by measuring the Brownian dynamics of 10 nm-radius gold and 57 nm-radius silica colloids in water at room temperature. In addition, the capability of the detector to faithfully record one- and two-photon counts was examined by comparing the statistical distribution of photon counts with expected probabilities from the negative binomial distribution. It was found that in burst mode the ratio of 2 s to 1 s is markedly smaller than predicted and that this is attributable to pixel-response dead-time.
- Published
- 2018
14. Evaluation of the UFXC32k photon-counting detector for pump-probe experiments using synchrotron radiation
- Author
-
Piotr Maj, Robert Szczygiel, F. Orsini, Brahim Kanouté, Claude Menneglier, Anna Koziol, Pawel Grybos, Arkadiusz Dawiec, Pascal Mercère, Michel Bordessoule, Paulo Da Silva, Alessandra Ciavardini, Claire Laulhé, and Kewin Desjardins
- Subjects
0301 basic medicine ,Physics ,030103 biophysics ,Nuclear and High Energy Physics ,Radiation ,Photon ,Pixel ,010308 nuclear & particles physics ,business.industry ,Astrophysics::High Energy Astrophysical Phenomena ,Detector ,Resolution (electron density) ,Synchrotron radiation ,Pump probe ,01 natural sciences ,Synchrotron ,law.invention ,03 medical and health sciences ,Optics ,law ,0103 physical sciences ,business ,Instrumentation ,Energy (signal processing) - Abstract
This paper presents the performance of a single-photon-counting hybrid pixel X-ray detector with synchrotron radiation. The camera was evaluated with respect to time-resolved experiments, namely pump–probe–probe experiments held at SOLEIL. The UFXC camera shows very good energy resolution of around 1.5 keV and allows the minimum threshold setting to be as low as 3 keV keeping the high-count-rate capabilities. Measurements of a synchrotron characteristic filling mode prove the proper separation of an isolated bunch of photons and the usability of the detector in time-resolved experiments.
- Published
- 2017
15. Voltage-Controlled Magnetic Anisotropy in an Ultrathin Fe Layer Sandwiched Between Cr and Mgo Layers
- Author
-
Witold Skowroński, Takayuki Nozaki, Shingo Tamaru, Yoshishige Suzuki, Akio Fukushima, Vadym Zayets, Shinji Yuasa, Hitoshi Kubota, Anna Koziol-Rachwal, and Yoichi Shiota
- Subjects
Tunnel magnetoresistance ,Magnetic anisotropy ,Materials science ,Ferromagnetism ,Magnetoresistance ,business.industry ,Optoelectronics ,Epitaxy ,Spin (physics) ,business ,Layer (electronics) ,Voltage - Abstract
Voltage-controlled magnetic anisotropy (VCMA) is increasingly gaining attention as a promising approach for low power manipulation method of spin [1]. The VCMA effect originates from voltage-induced charge accumulation/depletion at the interface of ultrathin ferromagnetic metal and insulative layers, such as in MgO-based magnetic tunnel junction (MTJ). One of the most important technical challenges for the VCMA effect is the scalability issue. For example, for G-bit class memory applications, high VCMA coefficient of more than 1000 fJ/Vm is demanded. However, the demonstrated VCMA effect with high speed response is limited to be only 100 fJ/Vm at present [2].
- Published
- 2016
- Full Text
- View/download PDF
16. Giant in-plane magnetic anisotropy in epitaxial bcc Co/Fe(110) bilayers
- Author
-
Tomasz Giela, Jörg Raabe, N. Pilet, P. Dróżdż, M. Ślęzak, T. Ślęzak, B. Matlak, D. Wilgocka-Ślęzak, Anna Koziol-Rachwal, K. Matlak, and Józef Korecki
- Subjects
Materials science ,Condensed matter physics ,02 engineering and technology ,021001 nanoscience & nanotechnology ,Epitaxy ,01 natural sciences ,Condensed Matter::Materials Science ,Magnetization ,In plane ,Magnetic anisotropy ,0103 physical sciences ,Monolayer ,010306 general physics ,0210 nano-technology ,Anisotropy - Abstract
We report on in-plane magnetic anisotropy in epitaxial bcc Co/Fe(110) bilayers on W(110). The magnetic surface anisotropy in the Co/Fe(110) bilayers exhibited a strong nonmonotonic dependence on Co coverage. Magneto-optical studies revealed a sharp maximum of the magnetic surface anisotropy, $2.44\phantom{\rule{0.16em}{0ex}}\mathrm{mJ}/{\mathrm{m}}^{2}$, at ${d}_{\mathrm{Co}}=5\phantom{\rule{0.16em}{0ex}}\AA{}$. This giant interfacial magnetic anisotropy allowed a small fraction of a Co monolayer to reorient the magnetization of the bulk-like Fe film. We conclude that the mono- and double-layer bcc Co(110) exhibited in-plane magnetic anisotropy with a $[1\overline{1}0]$ easy axis.
- Published
- 2016
- Full Text
- View/download PDF
17. 7.3kfps readout solution for 65k pixel X-Ray Camera working in zero dead-time mode
- Author
-
Piotr Maj and Anna Koziol
- Subjects
010302 applied physics ,Ethernet ,Physics ,Pixel ,010308 nuclear & particles physics ,business.industry ,Controller (computing) ,Interface (computing) ,Chip ,01 natural sciences ,Software ,0103 physical sciences ,Camera Link ,business ,Field-programmable gate array ,Computer hardware - Abstract
We present the FPGA implementation of the zero dead-time mode operation for the Ultra Fast X-Ray Camera. The camera consists of two UFXC32k chips bump-bonded to a single silicon sensor incorporated in a stand-alone camera communicating with an external system via Ethernet or Camera Link interface. Commercially available controller sbRIO 9651 including Zynq FPGA was used for both chip communication and Camera Link data streaming. Single software platform used for FPGA, Linux RT and Windows programming allows for efficient memory utilization and a high functionality operation in single-clock cycle in FPGA target as well as a multithread RT application in a state-machine paradigm. Presented solution allows for 7.3 kfps - the fastest framerate among commercial single photon counting x-ray cameras.
- Published
- 2016
- Full Text
- View/download PDF
18. Large Voltage-Induced Changes in the Perpendicular Magnetic Anisotropy of an MgO-Based Tunnel Junction with an Ultrathin Fe Layer
- Author
-
Akio Fukushima, Shingo Tamaru, Yoichi Shiota, Takayuki Nozaki, Anna Koziol-Rachwal, Shinji Yuasa, Hitoshi Kubota, Yoshishige Suzuki, Vadym Zayets, and Witold Skowroński
- Subjects
010302 applied physics ,Materials science ,Condensed matter physics ,Spintronics ,General Physics and Astronomy ,02 engineering and technology ,Condensed Matter::Mesoscopic Systems and Quantum Hall Effect ,021001 nanoscience & nanotechnology ,Epitaxy ,01 natural sciences ,Condensed Matter::Materials Science ,Tunnel magnetoresistance ,Magnetic anisotropy ,Ferromagnetism ,Tunnel junction ,Condensed Matter::Superconductivity ,0103 physical sciences ,0210 nano-technology ,Layer (electronics) ,Spin-½ - Abstract
Voltage control of magnetic anisotropy (VCMA) in an ultrathin ferromagnet metal layer is a promising approach for ultralow-power spin manipulation, but interface effects spoil its efficiency for applications such as memory devices. The authors study VCMA in the fully epitaxial ultrathin Fe layer of a magnetic tunnel junction, and achieve an efficiency of almost 300 fJ V${}^{-1}$ m${}^{-1}$ with high perpendicular anisotropy, which satisfies the requirements for gigabit-class spintronic memory.
- Published
- 2016
- Full Text
- View/download PDF
19. High speed systems for time-resolved experiments with synchrotron radiation
- Author
-
Piotr Maj and Anna Koziol
- Subjects
0301 basic medicine ,Physics ,030103 biophysics ,Physics::Instrumentation and Detectors ,010308 nuclear & particles physics ,business.industry ,Detector ,Bremsstrahlung ,Synchrotron radiation ,01 natural sciences ,Electromagnetic radiation ,Synchrotron ,Dot pitch ,Photon counting ,law.invention ,03 medical and health sciences ,Optics ,law ,0103 physical sciences ,business ,Instrumentation ,Mathematical Physics ,Pixel detector - Abstract
The UFXC32k is a single photon counting hybrid pixel detector with 75 μm pixel pitch. It was designed to cope with high X-ray intensities and therefore it is a very good candiate for synchrotron applications. In order to use this detector in an application, a dedicated setup must be designed and built allowing proper operation of the detector within the experiment. The paper presents two setups built for the purpose of Pump-Probe-Probe experiments at the Synchrotron SOLEIL and XPCS experiments at the APS.
- Published
- 2018
- Full Text
- View/download PDF
20. Methodology of automation process of wafer tests
- Author
-
Piotr Maj, Robert Szczygiel, Pawel Grybos, Anna Koziol, and A. Krzyżanowska
- Subjects
Engineering ,Software ,Pixel ,business.industry ,Embedded system ,Detector ,Process (computing) ,Wafer testing ,Wafer ,business ,Chip ,Automation - Abstract
The paper presents a highly efficient system for automated wafer testing implemented on a single software platform. Building fully functional device requires often expensive and time consuming, manufacturing steps. Thus, the ASICs on the wafer ought to be tested in advance to ensure that only the chips with no manufacturing defects will be used in the further process. The presented testing system was used for the tests of the readout chip for hybrid pixel detectors working in a single photon counting mode. The aim of the system is to detect both digital and analog blocks' issues that might cause incorrect chip functioning. The system setup, software implementation, the methodology and the choice of the tests performed are described.
- Published
- 2015
- Full Text
- View/download PDF
21. Highly efficient voltage control of spin and enhanced interfacial perpendicular magnetic anisotropy in iridium-doped Fe/MgO magnetic tunnel junctions
- Author
-
Tadakatsu Ohkubo, Shingo Tamaru, Anna Koziol-Rachwal, Takuya Tsukahara, Masafumi Shirai, Motohiro Suzuki, Shinji Yuasa, Kazuhiro Hono, Shinji Miwa, Xiandong Xu, Hitoshi Kubota, Takayuki Nozaki, Yoichi Shiota, Akio Fukushima, Masahito Tsujikawa, and Yoshishige Suzuki
- Subjects
010302 applied physics ,Magnetoresistive random-access memory ,Materials science ,Spintronics ,Magnetoresistance ,business.industry ,Magnetism ,02 engineering and technology ,021001 nanoscience & nanotechnology ,Condensed Matter Physics ,01 natural sciences ,Ferromagnetic resonance ,Condensed Matter::Materials Science ,Tunnel magnetoresistance ,Magnetic anisotropy ,Ferromagnetism ,Modeling and Simulation ,0103 physical sciences ,Optoelectronics ,General Materials Science ,0210 nano-technology ,business - Abstract
Voltage control of spin enables both a zero standby power and ultralow active power consumption in spintronic devices, such as magnetoresistive random-access memory devices. A practical approach to achieve voltage control is the electrical modulation of the spin–orbit interaction at the interface between 3d-transition-ferromagnetic-metal and dielectric layers in a magnetic tunnel junction (MTJ). However, we need to initiate a new guideline for materials design to improve both the voltage-controlled magnetic anisotropy (VCMA) and perpendicular magnetic anisotropy (PMA). Here we report that atomic-scale doping of iridium in an ultrathin Fe layer is highly effective to improving these properties in Fe/MgO-based MTJs. A large interfacial PMA energy, Ki,0, of up to 3.7 mJ m−2 was obtained, which was 1.8 times greater than that of the pure Fe/MgO interface. Moreover, iridium doping yielded a huge VCMA coefficient (up to 320 fJ Vm−1) as well as high-speed response. First-principles calculations revealed that Ir atoms dispersed within the Fe layer play a considerable role in enhancing Ki,0 and the VCMA coefficient. These results demonstrate the efficacy of heavy-metal doping in ferromagnetic layers as an advanced approach to develop high-density voltage-driven spintronic devices. Researchers from Japan's AIST demonstrated a new approach to reduce the energy consumption of spintronic devices. Magnetic random-access memory requires approximately 10,000 times more energy to record data than to safely maintain it — a discrepancy that arises due to the wastefulness of electric-current-based switching of magnetic bits. Takayuki Nozaki and colleagues now report a device that enables us to write magnetic memory using electric fields, a more energy-efficient control mechanism. The team introduced an iridium-doped ultrathin iron film in magnesium oxide-based magnetic tunnel junctions, and found that the heavy-metal dopants provoked a strong voltage-controlled magnetic anisotropy change with high-speed response. Physical role of heavy metal dopants was unveiled by first-principles calculations. The developed technique can lead to a new type of non-volatile memory with ultra-low energy consumption. Highly efficient voltage control of magnetic anisotropy has been demonstrated utlizing an ultrathin Ir-doped Fe layer in MgO-based magnetic tunnel junctions. Ir adoms are dispersed inside the ultrathin Fe layer through the interdiffusion process. Large spin–orbit interaction of Ir atoms having proximity-induced magnetism is attributed to the enhancement of the voltage-controlled magnetic anisotropy (VCMA) effect. High speed response of the VCMA effect was also confirmed by voltage-induced ferromagnetic resonance. The achieved properties first satisfy the required specification for the new type of magnetoresistive random access memory (MRAM) driven by voltage.
- Published
- 2017
- Full Text
- View/download PDF
22. Measurements of Ultra-Fast single photon counting chip with energy window and 75 μm pixel pitch with Si and CdTe detectors
- Author
-
Robert Szczygiel, Miroslaw Zoladz, Krzysztof Kasinski, A. Krzyżanowska, Anna Koziol, Pawel Grybos, Piotr Maj, and Piotr Kmon
- Subjects
Materials science ,Pixel ,010308 nuclear & particles physics ,business.industry ,Chip ,01 natural sciences ,Dot pitch ,Particle detector ,Photon counting ,030218 nuclear medicine & medical imaging ,Semiconductor detector ,03 medical and health sciences ,0302 clinical medicine ,Optics ,CMOS ,0103 physical sciences ,Neutron detection ,Optoelectronics ,business ,Instrumentation ,Mathematical Physics - Abstract
Single photon counting pixel detectors become increasingly popular in various 2-D X-ray imaging techniques and scientific experiments mainly in solid state physics, material science and medicine. This paper presents architecture and measurement results of the UFXC32k chip designed in a CMOS 130 nm process. The chip consists of about 50 million transistors and has an area of 9.64 mm × 20.15 mm. The core of the IC is a matrix of 128 × 256 pixels of 75 μm pitch. Each pixel contains a CSA, a shaper with tunable gain, two discriminators with correction circuits and two 14-bit ripple counters operating in a normal mode (with energy window), a long counter mode (one 28-bit counter) and a zero-dead time mode. Gain and noise performance were verified with X-ray radiation and with the chip connected to Si (320 μm thick) and CdTe (750 μ m thick) sensors.
- Published
- 2017
- Full Text
- View/download PDF
23. A new approach for a cameras backend design for the 75 µm pitch hybrid pixel detector
- Author
-
Anna Koziol, A. Drozd, Krzysztof Kasinski, Pawel Grybos, Piotr Maj, and Jacek Rauza
- Subjects
Engineering ,Pixel ,business.industry ,Controller (computing) ,Detector ,ComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISION ,USB ,Photon counting ,law.invention ,Microcontroller ,law ,Camera Link ,business ,Field-programmable gate array ,Computer hardware - Abstract
We report on the design of a portable X-Ray camera working in single photon counting mode and a very high frame rate exceeding 20000 fps. The camera consists of hybrid pixel detector, where a two readout ASICs consisting of 23552 pixels of 75um pitch are used. A new approach is used for designing the camera using the commercially available controller board supplied with Zynq FPGA, ARM controller and custom PCB integrating readout chips bump-bodnded to the silicon sensor, power supply, variety of communication ports including USB, Ethernet and Camera Link. All levels of the system (FPGA, microcontroller and Windows Application) are programmed with National Instruments LabVIEW allowing extreme acceleration of developing process due to single software platform.
- Published
- 2014
- Full Text
- View/download PDF
24. The effect of the MgO buffer layer thickness on magnetic anisotropy in MgO/Fe/Cr/MgO buffer/MgO(001)
- Author
-
Yoshishige Suzuki, Hitoshi Kubota, Anna Koziol-Rachwal, Shinji Yuasa, Takayuki Nozaki, Vadym Zayets, and Akio Fukushima
- Subjects
Kerr effect ,Materials science ,Analytical chemistry ,General Physics and Astronomy ,chemistry.chemical_element ,02 engineering and technology ,Substrate (electronics) ,Coercivity ,021001 nanoscience & nanotechnology ,Epitaxy ,01 natural sciences ,Chromium ,Magnetization ,Magnetic anisotropy ,Nuclear magnetic resonance ,chemistry ,0103 physical sciences ,010306 general physics ,0210 nano-technology ,Anisotropy - Abstract
The relationship between the magnetic properties and MgO buffer layer thickness d was studied in epitaxial MgO/Fe(t)/Cr/MgO(d) layers grown on MgO(001) substrate in which the Fe thickness t ranged from 0.4 nm to 1.1 nm. For 0.4 nm ≤ t ≤ 0.7 nm, a non-monotonic coercivity dependence on the MgO buffer thickness was shown by perpendicular magneto-optic Kerr effect magnetometry. For thicker Fe films, an increase in the buffer layer thickness resulted in a spin reorientation transition from perpendicular to the in-plane magnetization direction. Possible origins of these unusual behaviors were discussed in terms of the suppression of carbon contamination at the Fe surface and changes in the magnetoelastic anisotropy in the system. These results illustrate a method to control magnetic anisotropy in MgO/Fe/Cr/MgO(d) via an appropriate choice of MgO buffer layer thickness d.
- Published
- 2016
- Full Text
- View/download PDF
25. Hardware solutions for the 65k pixel X-ray camera module of 75 μm pixel size
- Author
-
Krzysztof Kasinski, Anna Koziol, Pawel Grybos, and Piotr Maj
- Subjects
010302 applied physics ,Materials science ,Pixel ,010308 nuclear & particles physics ,business.industry ,Detector ,ComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISION ,Integrated circuit ,USB ,01 natural sciences ,Photon counting ,law.invention ,CMOS ,law ,0103 physical sciences ,Camera Link ,business ,Instrumentation ,Mathematical Physics ,Computer hardware ,Camera module - Abstract
We present three hardware solutions designed for a detector module built with a 2 cm × 2 cm hybrid pixel detector built from a single 320 or 450 μ m thick silicon sensor designed and fabricated by Hamamatsu and two UFXC32k readout integrated circuits (128 × 256 pixels with 75μ m pitch, designed in CMOS 130 nm at AGH-UST). The chips work in a single photon counting mode and provide ultra-fast X-ray imaging. The presented hardware modules are designed according to requirements of various tests and applications: ⋅Device A: a fast and flexible system for tests with various radiation sources. ⋅Device B: a standalone, all-in-one imaging device providing three standard interfaces (USB 2.0, Ethernet, Camera Link) and up to 640 MB/s bandwidth. ⋅Device C: a prototype large-area imaging system. The paper shows the readout system structure for each case with highlighted circuit board designs with details on power distribution and cooling on both FR4 and LTCC (low temperature co-fired ceramic) based circuits.
- Published
- 2016
- Full Text
- View/download PDF
26. Growth and magnetic properties of ultrathin epitaxial FeO films and Fe/FeO bilayers on MgO(001)
- Author
-
Józef Korecki, T. Ślęzak, Anna Koziol-Rachwal, Shinji Yuasa, and Takayuki Nozaki
- Subjects
Materials science ,Physics and Astronomy (miscellaneous) ,Bilayer ,Inorganic chemistry ,Oxide ,Analytical chemistry ,02 engineering and technology ,021001 nanoscience & nanotechnology ,Epitaxy ,01 natural sciences ,Overlayer ,Chemical state ,chemistry.chemical_compound ,Exchange bias ,chemistry ,Conversion electron mössbauer spectroscopy ,0103 physical sciences ,010306 general physics ,0210 nano-technology ,Molecular beam epitaxy - Abstract
Ultrathin FeO(001) films were grown via molecular beam epitaxy on MgO(001) using reactive deposition of Fe. The growth conditions were adjusted toward stabilization of the wustite phase, the existence of which was confirmed by means of conversion electron Mossbauer spectroscopy. It was shown how the metallic Fe overlayer modified the chemical state and the magnetic properties of the FeO oxide. Finally, we observed the exchange bias for an epitaxial Fe/FeO bilayer grown on MgO(001).
- Published
- 2016
- Full Text
- View/download PDF
27. Single software platform used for high speed data transfer implementation in a 65k pixel camera working in single photon counting mode
- Author
-
Robert Szczygiel, P. Gryboś, Anna Koziol, Krzysztof Kasinski, and Piotr Maj
- Subjects
Computer science ,business.industry ,Interface (computing) ,law.invention ,Microprocessor ,Software ,Application-specific integrated circuit ,law ,Personal computer ,Camera Link ,business ,Field-programmable gate array ,Instrumentation ,Mathematical Physics ,Computer hardware ,Data transmission - Abstract
Integrated circuits designed for specific applications generally use non-standard communication methods. Hybrid pixel detector readout electronics produces a huge amount of data as a result of number of frames per seconds. The data needs to be transmitted to a higher level system without limiting the ASIC's capabilities. Nowadays, the Camera Link interface is still one of the fastest communication methods, allowing transmission speeds up to 800 MB/s. In order to communicate between a higher level system and the ASIC with a dedicated protocol, an FPGA with dedicated code is required. The configuration data is received from the PC and written to the ASIC. At the same time, the same FPGA should be able to transmit the data from the ASIC to the PC at the very high speed. The camera should be an embedded system enabling autonomous operation and self-monitoring. In the presented solution, at least three different hardware platforms are used—FPGA, microprocessor with real-time operating system and the PC with end-user software. We present the use of a single software platform for high speed data transfer from 65k pixel camera to the personal computer.
- Published
- 2015
- Full Text
- View/download PDF
28. Photoinduced ring expansion of cyclobutyliron .sigma.-complexes: an example of rearrangement of an aryl group from saturated carbon to a transition metal to give a carbene complex
- Author
-
Yngve Stenstroem, Guenter Klauck, Anna Koziol, Gus J. Palenik, and W. M. Jones
- Subjects
Inorganic Chemistry ,Organic Chemistry ,Physical and Theoretical Chemistry - Published
- 1986
- Full Text
- View/download PDF
29. Sis and pharmacological activity of 1,8,11,11-tetramethyl-4- azatricyclo[5.2.2.02,6]undec-8-ene-3,5-dione derivatives
- Author
-
Pakosińska-Parys, M., Kossakowski, J., Mirosław, B., Anna Koziol, and Stefańska, J.
30. Thiourea derivatives of 4-azatricyclo[5.2.2.02,6]undec-8-ene-3,5-dione - Synthesis and biological activity
- Author
-
Bielenica, A., Stefańska, J., Kozioł, A. E., Iuliano, F., Collu, D., Anna Koziol, Jóźwiak, M., and Struga, M.
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.