Search

Your search keyword '"Yuji Nakaguchi"' showing total 57 results

Search Constraints

Start Over You searched for: Author "Yuji Nakaguchi" Remove constraint Author: "Yuji Nakaguchi" Language undetermined Remove constraint Language: undetermined
57 results on '"Yuji Nakaguchi"'

Search Results

2. Impact of treatment planning quality assurance software on volumetric-modulated arc therapy plans for prostate cancer patients

3. [Methodologies and Necessity for IMRT Verification]

4. Image quality of four-dimensional cone-beam computed tomography obtained at various gantry rotation speeds for liver stereotactic body radiation therapy with fiducial markers

5. Validation of a method for in vivo 3D dose reconstruction in <scp>SBRT</scp> using a new transmission detector

6. Evaluation of Absorbed Dose for CBCT in Image-guided Radiation Therapy: Comparison of Each Devices and Facilities

7. 8. Commissioning and Quality Assurance of Image Guided Radiation Therapy(IGRT)

8. Modalities and techniques used for stereotactic radiotherapy, intensity-modulated radiotherapy, and image-guided radiotherapy: A 2018 survey by the Japan Society of Medical Physics

9. Dynamic positioning accuracy of a novel multileaf collimator for volumetric modulated arc therapy

10. Validation of secondary dose calculation system with manufacturer-provided reference beam data using heterogeneous phantoms

11. Accuracy of dose calculation algorithms for virtual heterogeneous phantoms and intensity-modulated radiation therapy in the head and neck

12. Validation of fluence-based 3D IMRT dose reconstruction on a heterogeneous anthropomorphic phantom using Monte Carlo simulation

13. Commissioning and validation of fluence-based 3D VMAT dose reconstruction system using new transmission detector

15. Optimization of acquisition parameters and accuracy of target motion trajectory for four-dimensional cone-beam computed tomography with a dynamic thorax phantom

16. Validation of a quick three-dimensional dose verification system for pre-treatment IMRT QA

17. Development of a Quality Assurance Phantom for Brachytherapy: The Feasibility of Daily Check with the Phantom

18. A Comparison of Four Commercial Radiation Treatment Planning Systems for Prostate Intensity Modulated Radiation Therapy

19. Development of multi-planar dose verification by use of a flat panel EPID for intensity-modulated radiation therapy

20. Comparison of Dose Accuracy between 2D Array Detectors for Pre-treatment IMRT QA

21. Longitudinal Changes over 2 Years in Parotid Glands of Patients Treated with Preoperative 30-Gy Irradiation for Oral Cancer

22. Participate in ECR 2010

23. Comparison of 3-dimensional dose reconstruction system between fluence-based system and dose measurement-guided system

24. [Potential uncertainty about image registration in thoracic image-guided radiotherapy]

25. Absorbed dose measurements for kV-cone beam computed tomography in image-guided radiation therapy

26. 3D evaluation of 3DVH program using BANG3 polymer gel dosimeter

27. [Physical characterizations for an integrated 160-leaf multi-leaf collimator with a new concept design]

28. [Dose distribution from kV-cone beam computed tomography in image-guided radiotherapy]

30. [Practical method for six-dimensional online correction system with image guided radiation therapy]

31. [Quality assurance of respiratory-gated stereotactic body radiation therapy in lung using real-time position management system]

32. Plan Quality and Delivery Time Comparisons Between Volumetric Modulated Arc Therapy and Intensity Modulated Radiation Therapy for Scalp Angiosarcoma: A Planning Study Using X-ray Voxel Monte Carlo Algorithm

33. SU-F-T-549: Validation of a Method for in Vivo 3D Dose Reconstruction for SBRT Using a New Transmission Detector

34. SU-F-T-364: Monte Carlo-Dose Verification of Volumetric Modulated Arc Therapy Plans Using AAPM TG-119 Test Patterns

35. SU-G-JeP4-06: Evaluation of Interfractional and Intrafractional Tumor Motion in Stereotactic Liver Radiotherapy, Based On Four-Dimensional Cone-Beam Computed Tomography Using Fiducial Markers

36. Evaluation of target localization accuracy for image-guided radiation therapy by 3D and 4D cone-beam CT in the presence of respiratory motion: a phantom study

37. [Comparison of various image guided radiation therapy systems; image-guided localization accuracy and patient throughput]

38. FDG-PET/CT-based gross tumor volume contouring for radiation therapy planning: an experimental phantom study

39. [Cone-beam computed tomography-derived adaptive radiotherapy]

40. Histopathological Changes in Parotid and Submandibular Glands of Patients Treated with Preoperative Chemoradiation Therapy for Oral Cancer

41. [Dosimetric correction for a six degrees carbon fiber couch]

42. Recurrence patterns of glioblastoma treated with postoperative radiation therapy: relationship between extent of resection and progression-free interval

43. Dose verification of IMRT by use of a COMPASS transmission detector

44. Comparison of RTPS and Monte Carlo dose distributions in heterogeneous phantoms for photon beams

45. Monte Carlo-calculated patient organ doses from kV-cone beam CT in image-guided radiation therapy

46. SU-E-T-342: Dynamic Accuracy and Stability of Novel Multi-Leaf Collimator (MLC) for Volumetric Modulated Arc Therapy (VMAT)

47. Corrigendum: Absorbed dose measurements for kV-cone beam computed tomography in image-guided radiation therapy (Phys. Med. Biol. 59 7297)

48. Can MRI-derived Factors Predict Survival in Patients with Glioblastoma Multiforme?

Catalog

Books, media, physical & digital resources