Martínez Solano, Francisco Javier, Iglesias Rey, Pedro Luis, Universitat Politècnica de València. Departamento de Ingeniería Hidráulica y Medio Ambiente - Departament d'Enginyeria Hidràulica i Medi Ambient, Rodríguez Pacheco, Daniel Abdalá, Martínez Solano, Francisco Javier, Iglesias Rey, Pedro Luis, Universitat Politècnica de València. Departamento de Ingeniería Hidráulica y Medio Ambiente - Departament d'Enginyeria Hidràulica i Medi Ambient, and Rodríguez Pacheco, Daniel Abdalá
[ES] El presente trabajo tiene como objetivo la elaboración del modelo matemático de la red de distribución de agua potable del cantón Sucúa, el cual permitirá realizar un diagnóstico del estado actual del sistema, identificar los principales problemas de la red y posteriormente realizar propuestas de mejoras. Además, se evaluará el comportamiento que tuvo el sistema de Sucúa con la unificación del sistema de Santa Marianita, la cual se realizó en mayo del 2016. Para realizar el modelo matemático se dispone de información proporcionada por la empresa municipal EPMAPA-S, la cual fue entregada en formato digital. El software que se ha utilizado para la simulación hidráulica es Epanet 2.0. El modelo matemático ha sido creado basándose en los datos y registros de diciembre de 2014, debido a que, para esa fecha existen datos de caudal inyectado al sistema (macromedición). Con los volúmenes inyectados y facturados se ha calculado el balance hídrico técnico de la red y se ha estimado el rendimiento volumétrico global del sistema (48.1 %), el cual le corresponde una calificación de “Inaceptable”. La esqueletización de la red se ha realizado con el plano base de redes del cantón. Para la asignación de cotas en los nodos se ha utilizado las curvas de nivel de la zona y para la asignación de demandas en los nodos se empleó los consumos mensuales registrado por los micromedidores. La calibración del modelo matemático ha sido realizada en dos fases; la fase I propuso un ajuste diario, mediante la estimación de un valor del coeficiente global de los emisores y la fase II formula el ajuste horario, mediante el ajuste del patrón de variación temporal de la demanda. El principal problema que presenta el sistema es el elevado porcentaje de fugas, el cual está asociado a las sobrepresiones de la red, estas presiones superan los límites permisibles por la normativa nacional. Es por ello, como propuesta de mejora se ha planteado realizar la gestión de las presiones mediante la instalaci, [EN] The objective of this work is to develop a mathematical model of the drinking water distribution network in the canton of Sucúa, which will allow a diagnosis of the current state of the system, identify the main problems of the network and subsequently make proposals for improvements. In addition, the behavior of the Sucúa system will be evaluated with the unification of the Santa Marianita system, which took place in May 2016. To make the mathematical model, information provided by the municipal company EPMAPA-S is available, which was delivered in digital format. The software used for the hydraulic simulation is Epanet 2.0. The mathematical model has been created based on the data and records from December 2014, because, by that date there is data of flow injected into the system (macro-measurement). With the volumes injected and invoiced, the technical water balance of the network has been calculated and the global volumetric yield of the system has been estimated (48.1 %), which corresponds to a qualification of "Unacceptable". The skeletonisation of the network has been carried out with the base plan of the canton's networks. For the assignment of the node levels, the area's contour lines have been used and the assignment of the node demands, the monthly consumption recorded by the micro-meters has been used. The calibration of the mathematical model has been carried out in two phases; phase I proposed a daily adjustment, by estimating a value of the global coefficient of the emitters and phase II formulates the hourly adjustment, by adjusting the pattern of temporal variation of the demand. The main problem presented by the system is the high percentage of leaks, which is associated with network overpressures, these pressures exceed the limits permitted by national regulations. For this reason, as a proposal for improvement, pressure management has been proposed by installing pressure reduction valves, this has reduced the average pressure from 43.2 mca t, [CA] El present treball té com a objectiu l'elaboració del model matemàtic de la xarxa de distribució d'aigua potable del cantó Sucúa, el qual permetrà realitzar un diagnòstic de l'estat actual del sistema, identificar els principals problemes de la xarxa i posteriorment realitzar propostes de millores. A més, s'avaluarà el comportament que va tindre el sistema de Sucúa amb la unificació del sistema de Santa Marianita, la qual es va realitzar al maig del 2016. Per a realitzar el model matemàtic es disposa d'informació proporcionada per l'empresa municipal EPMAPA-S, la qual va ser entregada en format digital. El programari que s'ha utilitzat per a la simulació hidràulica és Epanet 2.0. El model matemàtic ha sigut creat sobre la base de les dades i registres de desembre de 2014, pel fet que, per a aqueixa data existeix dades de cabal injectat al sistema (macromedición). Amb els volums injectats i facturats s'ha calculat el balanç hídric tècnic de la xarxa i s'ha estimat el rendiment volumètric global del sistema (48.1%), el qual li correspon una qualificació de “Inacceptable”. L'esqueletización de la xarxa s'ha realitzat amb el pla base de xarxes del cantó. Per a l'assignació de cotes en els nodes s'ha utilitzat les corbes de nivell de la zona i l'assignació de demandes en els nodes es va emprar els consums mensuals registrat pels micromedidores. El calibratge del model matemàtic ha sigut realitzada en dues fases; la fase I va proposar un ajust diari, mitjançant l'estimació d'un valor del coeficient global dels emissors i la fase II formula l'ajust horari, mitjançant l'ajust del patró de variació temporal de la demanda. El principal problema que presenta el sistema és l'elevat percentatge de fugides, el qual està associat a les sobrepressions de la xarxa, aquestes pressions superen els límits permissibles per la normativa nacional. És per això, com a proposta de millora s'ha plantejat realitzar la gestió de les pressions mitjançant la instal·lació de vàlvules reductor