6 results on '"Fernando Lozano Ruíz-Poveda"'
Search Results
2. Discordance between fractional flow reserve and nonhyperemic index with a fiber-optic pressure wire. READI EPIC-14
- Author
-
Mario Sádaba Sagredo, Asier Subinas Elorriaga, Sebastián Romaní Ménde, Daniel Valcárcel Paz, Rocío Angulo Llanos, Carlos Lara García, Alicia Quirós, Erika Muñoz García, Ángel Sánchez Recalde, Javier Robles Alonso, Fernando Lozano Ruiz-Poveda, Francisco Javier Irazusta, Alfredo Redondo, Rosa Alba Abellás Sequeiros, and Oriol Rodríguez-Leor
- Subjects
Coronary physiology ,Fractional flow reserve ,Nonhyperemic index ,Discordance ,Drift ,Medicine - Abstract
ABSTRACT Introduction and objectives: Functional assessment of coronary stenosis severity with the piezo-electric sensor pressure wire has shown a discrepancy of up to 20% between hyperemic and nonhyperemic indexes. No data are available with fiber-optic pressure wires. The aim of this study was to evaluate the incidence and factors related to the diagnostic discordance between these indexes with a fiber-optic pressure wire. Secondary aims were to assess diagnostic reproducibility in 2 consecutive measurements of fractional flow reserve (FFR) and diastolic pressure ratio (dPR) and evaluate the drift rate. Methods: We conducted a prospective, observational multicenter study in patients undergoing functional assessment with a fiber-optic pressure wire. We took 2 consecutive measurements of the dPR (cutoff point 0.89) and FFR (cut-off point 0.80) in each lesion analyzed. The diagnostic correlation between 2 measurements with the same technique and between the 2 techniques (dPR and FFR) was assessed. Clinical and angiographic factors associated with discordance (FFR−/dPR+ and FFR+/dPR−) between the 2 techniques were analyzed. Results: We included 428 cases of stenosis (361 patients). Diagnostic reproducibility was 95.8% for the dPR, with a correlation coefficient between the 2 measurements (dPR1 and dPR2) of 0.974 (P 60%. The drift rate was 5.7%. Conclusions: Although FFR and dPR measurements with a fiber-optic pressure wire have excellent reproducibility and a low drift rate, the discordance rate remains similar to those in previous studies with a piezo-electric pressure wire. FFR−/dPR+ discordance is associated with intracoronary adenosine and hypertension. FFR+/dPR− discordance is related to age < 75 years old and stenosis > 60%.
- Published
- 2024
- Full Text
- View/download PDF
3. Discordancia entre la reserva fraccional de flujo y el índice no hiperémico con guía de presión de sensor óptico. READI EPIC-14
- Author
-
Mario Sádaba Sagredo, Asier Subinas Elorriaga, Sebastián Romaní Méndez, Daniel Valcárcel Paz, Rocío Angulo Llanos, Carlos Lara García, Alicia Quirós, Erika Muñoz García, Ángel Sánchez Recalde, Javier Robles Alonso, Fernando Lozano Ruiz-Poveda, Francisco Javier Irazusta, Alfredo Redondo, Rosa Alba Abellás Sequeiros, and Oriol Rodríguez-Leor
- Subjects
Fisiología coronaria ,Reserva fraccional de flujo ,Índice no hiperémico ,Discordancia ,Drift ,Internal medicine ,RC31-1245 - Abstract
RESUMEN Introducción y objetivos: La valoración funcional de las estenosis coronarias con guías de presión de sensor piezoeléctrico ha mostrado hasta un 20% de discordancia entre los índices hiperémico y no hiperémico. No hay datos disponibles con guía de presión de sensor óptico. El objetivo del estudio es evaluar la incidencia y los factores relacionados con la discordancia diagnóstica entre estos índices con guía de presión de sensor óptico. Como objetivos secundarios se evaluó la reproducibilidad diagnóstica en dos determinaciones consecutivas de la reserva fraccional de flujo (RFF) y la diastolic pressure ratio (dPR). También se evaluó la tasa de drift. Métodos: Estudio observacional, prospectivo, multicéntrico, en pacientes a quienes se realiza una valoración funcional con guía de presión de sensor óptico. Se hicieron dos mediciones consecutivas de dPR (umbral 0,89) y RFF (umbral 0,80) en cada lesión analizada. Se valoró la correlación diagnóstica entre dos mediciones con la misma técnica y entre ambas técnicas (dPR y RFF). Se analizaron factores clínicos y angiográficos asociados a la discordancia (RFF−/dPR+ y RFF+/dPR−) entre ambas técnicas. Resultados: Se incluyeron 428 estenosis (361 pacientes). La reproducibilidad diagnóstica fue del 95,8% para dPR, con un coeficiente de correlación entre ambas mediciones (dPR1 y dPR2) de 0,974 (p < 0,0001). Para RFF la reproducibilidad diagnóstica fue del 94,9%, con un coeficiente de correlación (RFF1 y RFF2) de 0,942 (p < 0,0001). La discordancia diagnóstica fue del 18,2% (RFF+/dPR− 8,2% y RFF−/dPR+ 10%). Entre las variables analizadas, en el análisis multivariado, la hipertensión arterial y la administración intracoronaria de adenosina se asociaron de manera significativa con la discordancia RFF−/dPR+. Solo la edad < 75 años y la estenosis > 60% se asociaron de manera significativa con la discordancia RFF+/dPR−. La tasa de drift fue del 5,7%. Conclusiones: Aunque las mediciones de RFF y dPR con guía de presión de sensor óptico tienen una excelente reproducibilidad y una baja incidencia de drift, la tasa de discordancia permanece similar a la de estudios previos con guía de presión de sensor piezoeléctrico. La adenosina intracoronaria y la hipertensión arterial se asocian con la discordancia RFF−/dPR+. La edad < 75 años y la estenosis > 60% se asocian a discordancia RFF+/dPR−.
- Published
- 2024
- Full Text
- View/download PDF
4. Bioactive or Drug-Eluting Stents in 75 Years or Older Patients: The BIODES-75 Registry
- Author
-
Juan G. Córdoba-Soriano, Antonio Gutiérrez-Díez, Bruno García Del Blanco, Julio Núñez, Ignacio J. Amat-Santos, Juan Francisco Oteo, Rafael Romaguera, Arsenio Gallardo-López, Fernando Lozano Ruíz-Poveda, Pascual Baello, Pablo Aguar, Miguel Jerez-Valero, Víctor Alfonso Jiménez-Díaz, Bernat Serra, Jose Domingo Cascon, Francisco J. Morales-Ponce, Juan José Portero-Portaz, Driss Melehi El Assali, Pablo Cerrato-García, and Jesús Jiménez-Mazuecos
- Subjects
Percutaneous Coronary Intervention ,Time Factors ,Treatment Outcome ,Myocardial Infarction ,Humans ,Drug-Eluting Stents ,Stents ,General Medicine ,Prospective Studies ,Registries ,Cardiology and Cardiovascular Medicine ,Aged ,Retrospective Studies - Abstract
TiNO-coated BAS have demonstrated competitive outcomes compared to drug-eluting stents (DES). These devices allow short antiplatelet regimens and may be a good option for the growing elderly population undergoing percutaneous coronary intervention (PCI).Multicenter observational trial in routine clinical practice. A propensity-score matched analysis compared a prospective cohort of patients ≥ 75 years undergoing PCI with BAS, with a contemporary and retrospective cohort treated with last-generation DES. The co-primary endpoints of the study were the Target-Lesion-Failure (Cardiac death, non-fatal myocardial infarction, or target lesion revascularization) and Major Adverse Cardiovascular Events (total death, non-fatal myocardial infarction, stroke, or new revascularization) at 1 year.Whole population included 1000 patients, and 326 patients in each group were matched for analysis. No differences in primary endpoints were found: TLF 10.4% vs. 11% (HR 0.96 (Confidence Interval 95%, 0.36-1.7; p = 0.87)) and MACE 16.3% vs. 17.2% (HR 0.98 (Confidence Interval 95%; 0.3-1.5, p = 0.93)). Patients treated with BAS received shorter antiplatelets regimens (dual antiplatelet therapy at 1 year, 25.7% vs. 70.6%, p = 0.0001), and they presented lower incidence of bleeding (3.7% vs. 11.7%, HR 0.3 (IC 95% 0.16-0.6, p = 0.001)).In this real-life registry of patients ≥ 75 years, BAS were similar to the latest-generation DES in terms of efficacy and reduced the duration of the antithrombotic therapy, lowering bleeding events.
- Published
- 2022
5. Efectividad del balón no distensible con punta esférica en posdilatación coronaria: estudio REPIC02-RECONQUISTHA
- Author
-
José Antonio Linares Vicente, Koldo García San Román, Fernando Lozano Ruiz-Póveda, Gabriela Veiga Fernández, Antonio Gómez Menchero, Gerardo Moreno Terribas, Gema Miñana Escrivà, Joaquín Sánchez Gila, Carlos Arellano Serrano, José Ramón Rumoroso Cuevas, Ginés Martín Cáceres, Pablo Bazal Chacón, Pedro Martín Lorenzo, Fernando Rebollal Leal, José Moreu Burgos, and Armando Pérez de Prado
- Subjects
Intervención coronaria percutánea compleja ,Posdilatación coronaria ,Balón no distensible ,Balón no distensible punta esférica ,Internal medicine ,RC31-1245 - Abstract
RESUMEN Introducción y objetivos: La posdilatación de stents coronarios con balones no distensibles mejora los resultados clínicos. Los balones no distensibles normales (RegNC) presentan peor navegabilidad y tienen una punta cónica que puede dificultar la posdilatación exitosa. Las condiciones mecánicas de un nuevo balón no distensible con punta esférica (EsfNC) podrían facilitar la posdilatación del stent. Evaluamos la efectividad del EsfNC en la posdilatación coronaria para la intervención coronaria percutánea en la práctica clínica habitual. Métodos: Registro técnico prospectivo y multicéntrico para evaluar la efectividad de un nuevo EsfNC en posdilatación coronaria, con 2 grupos de estudio: uso de EsfNC como primera opción o uso de EsfNC ante el fracaso de RegNC. El evento primario fue el éxito técnico, definido como conseguir avanzar el EsfNC hasta el segmento que posdilatar dentro del stent. Los eventos secundarios fueron el éxito angiográfico, definido como éxito técnico junto con estenosis residual < 30% con flujo final TIMI 3, y el éxito del procedimiento, definido como éxito angiográfico sin complicación mecánica del stent ni eventos cardiovasculares mayores periprocedimiento. Resultados: Se usó EsfNC en 263 lesiones (en 177 como primera opción y en 86 tras el fracaso de RegNC), en 250 procedimientos. Se usaron técnicas complejas para avanzar el EsfNC en el 9,9% de los procedimientos. Los porcentajes de éxito técnico, angiográfico y de procedimiento fueron del 98,9%, el 98,3% y el 98,3% como primera opción, y del 98,8%, el 97,7% y el 96,5% tras fracaso de RegNC, respectivamente. Los EsfNC tuvieron similar calibre (3,39 ± 0,6 frente a 3,34 ± 0,6 mm; p = no significativo) y longitud más corta (11 ± 2 frente a 12 ± 3 mm; p = 0,005) que los RegNC. No se comunicaron complicaciones mecánicas del stent. Conclusiones: La posdilatación coronaria con EsfNC para la intervención coronaria percutánea en la práctica clínica habitual muestra un porcentaje muy alto de éxito técnico, tanto en primera opción (98,9%) como en casos de fracaso de RegNC (98,8%), con baja necesidad de técnicas complejas y buen perfil de seguridad.
- Published
- 2022
- Full Text
- View/download PDF
6. Effectiveness of spherical tip noncompliant balloon for stent postdilatation: the REPIC02-RECONQUISTHA study
- Author
-
José Antonio Linares Vicente, Koldo García San Román, Fernando Lozano Ruiz-Póveda, Gabriela Veiga Fernández, Antonio Gómez Menchero, Gerardo Moreno Terribas, Gema Miñana Escrivà, Joaquín Sánchez Gila, Carlos Arellano Serrano, José Ramón Rumoroso Cuevas, Ginés Martín Cáceres, Pablo Bazal Chacón, Pedro Martín Lorenzo, Fernando Rebollal Leal, José Moreu Burgos, and Armando Pérez de Prado
- Subjects
Complex PCI ,Stent postdilatation ,Tapered-tip balloon ,Spherical tip balloon ,Medicine - Abstract
ABSTRACT Introduction and objectives: Noncompliant balloon postdilatation of coronary stents improves clinical results. Regular noncompliant balloons (RegNC) have less crossability and a tapered-tip that can complicate successful stent postdilatation. The mechanical conditions of a new spherical tip non-compliant balloon (SphNC) could facilitate stent postdilatation. We tried to evaluate the effectiveness of a new SphNC in the routine percutaneous coronary intervention (PCI) practice. Methods: Prospective multicenter technical registry to assess the effectiveness of a new SphNC for stent postdilatation with 2 study arms: use of SphNC as the first choice or as the secondary choice after RegNC failure. The primary endpoint was technical success defined as advancing the SphNC across the stent segment. Secondary endpoints were angiographic success defined as technical success and residual stenosis < 30% with final TIMI grade-3 flow, and procedural success defined as angiographic success without mechanical stent complications or any perioperative major adverse cardiovascular events. Results: The SphNC was used in 263 lesions (177 lesions as first choice, and 86 after RegNC failure) in 250 procedures. The use of the complex technique to advance the SphNC was low (9.9%). Technical, angiographic, and procedural success rates were 98.9%, 98.3%, and 98.3%, respectively, as the first choice, and 98.8%, 97.7%, and 96.5%, respectively, after RegNC failure. SphNC had similar size (3.39 mm ± 0.6 mm vs 3.34 mm ± 0.6 mm; P = nonsignificant), and shorter lengths (11 mm ± 2 mm vs 12 mm ± 3 mm; P = .005) compared to RegNC. No stent-related mechanical complications were reported. Conclusions: SphNC for coronary stent postdilatation in the routine PCI clinical practice has a very high technical success rate as the first choice (98.9%), as well as in cases of RegNC failure (98.8% with low complex technique requirements, and a safe profile).
- Published
- 2022
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.