10 results on '"Técnica para Retentor Intrarradicular"'
Search Results
2. KNOWLEDGE OF DENTAL SURGEONS IN THE SELECTION AND CEMENTATION OF FIBERGLASS POSTS
- Author
-
Corrêa Gomes, Karollayne Khálitta, Dias, Mariana Marins, Rosário de Sousa, Elisabete Aparecida, Dias, Pâmella Coelho, Viana, Henrique Cury, Corrêa Gomes, Karollayne Khálitta, Dias, Mariana Marins, Rosário de Sousa, Elisabete Aparecida, Dias, Pâmella Coelho, and Viana, Henrique Cury
- Abstract
The aim of this study is to record the knowledge of dentists in relation to the selection and cementation technique of the fiberglass post in the daily routine of dental professionals to check which fiberglass post brand and anatomy are most used; to describe the reasons that lead the professionals to choose this technique, as well as analyze the types of cement available and the one most used by dentists in cementing the fiberglass post. In addition to helping dental students with information on the topic, taking into account the fact that this type of retainer is a great choice for the reconstruction of endodontically treated teeth, as it is a cost-effective material, it is resistant to chewing forces, aesthetic and simple technique. To carry out the research, an electronic questionnaire was applied, with objective questions for dental students from Faculdade Patos de Minas (FPM), via a Google Forms form, aiming to acquire data on how the dentists use the fiberglass post. Given the results obtained, among the materials used for cementing the post, there was a great preference for dual resin cement, as it has a good adhesion and resistance, however, it has an unsatisfactory polymerization. Furthermore, it was observed that the self-adhesive resin cement launched on the market recently has been highly praised for presenting several advantages. It is concluded that dual resin cement is the most used by dentists in dental offices today, but self-adhesive cement has been the best choice, as it presents properties similar to previous cements and resistance equivalent to conventional cements according to the literature researched., El objetivo de este estudio es registrar el conocimiento de los odontólogos en relación con la técnica de selección y cementación del poste de fibra de vidrio en la rutina diaria de los profesionales dentales para comprobar qué marca de poste de fibra de vidrio y anatomía son las más utilizadas; describir las razones que llevan a los profesionales a elegir esta técnica, así como analizar los tipos de cemento disponibles y el más utilizado por los dentistas en la cementación del poste de fibra de vidrio. Además de ayudar a los estudiantes de odontología con información sobre el tema, teniendo en cuenta el hecho de que este tipo de retenedor es una gran opción para la reconstrucción de dientes tratados endodónticamente, ya que es un material rentable, es resistente a las fuerzas de masticación, técnica estética y simple. Para llevar a cabo la investigación, se aplicó un cuestionario electrónico, con preguntas objetivas para estudiantes de odontología de la Facultad de Patos de Minas (FPM), a través de un formulario de Google Forms, con el objetivo de adquirir datos sobre cómo los dentistas utilizan el poste de fibra de vidrio. Dados los resultados obtenidos, entre los materiales utilizados para cementar el poste, hubo una gran preferencia por el cemento de resina dual, ya que tiene una buena adherencia y resistencia, sin embargo, tiene una polimerización insatisfactoria. Además, se observó que el cemento de resina autoadhesivo lanzado al mercado recientemente ha sido muy elogiado por presentar varias ventajas. Se concluye que el cemento de resina dual es el más utilizado por los dentistas en los consultorios dentales en la actualidad, pero el cemento autoadhesivo ha sido la mejor opción, ya que presenta propiedades similares a los cementos anteriores y una resistencia equivalente a los cementos convencionales según la literatura investigada., Esse trabalho teve como objetivo registrar conhecimentos do Cirurgiões Dentistas - CD em relação à seleção e técnica de cimentação de Pinos de Fibra de Vidro - PFV na rotina dos profissionais de odontologia; verificar qual a marca e anatomia de PFV mais utilizados; descrever os motivos que levam os profissionais a escolherem essa técnica, como também, analisar os tipos de cimentos disponíveis e o mais utilizado pelos CD na cimentação do PFV. Além de auxiliar os alunos com informações sobre o tema, levando em consideração o fato de que esse tipo de retentor é uma ótima escolha para a reconstrução de dentes tratados endodonticamente, por se tratar de um material com bom custo-benefício, resistência às forças mastigatórias, estética e facilidade da técnica. Para efetivação da pesquisa foi aplicado um questionário eletrônico, com questões objetivas para os CD egressos da Faculdade Patos de Minas (FPM), via formulário no google forms, visando adquirir dados de como o CD utiliza o PFV. Essa pesquisa possui aprovação de Comitê de Ética em Pesquisa (CEP) da Faculdade Patos de Minas (FPM), parecer nº 6.034.665, Diante dos resultados obtidos, dentre os materiais utilizados para a cimentação do pino, houve uma grande predileção pelo cimento resinoso dual, por apresentar boa adesão e resistência, porém, este possui uma polimerização insatisfatória. Além disso, observou-se que o cimento resinoso autoadesivo lançado no mercado recentemente vem sendo bastante enaltecido por apresentar diversas vantagens. Conclui-se que o cimento resinoso dual é o mais utilizado pelos cirurgiões dentistas nos consultórios odontológicos atualmente, porém o cimento autoadesivo vem sendo a melhor escolha, por apresentar propriedades similares aos cimentos anteriores e resistência equivalente aos cimentos convencionais de acordo com a literatura pesquisada.
- Published
- 2023
3. Comparison of conventional fiberglass and splendor sap post systems
- Author
-
Flávio Warol and Victor Talarico Leal Vieira
- Subjects
Técnica de perno muñón ,Tooth, nonvital ,General Earth and Planetary Sciences ,Post and core technique ,Técnica para retentor intrarradicular ,Diente no vital ,Ciência dos materiais ,Ciencia de los materiales ,Dente não vital ,Materials science ,General Environmental Science - Abstract
The aim of this study was to compare the effect of posts systems and the luting agent on bond strength. Thirty single-rooted bovine teeth were used. The specimens were randomly grouped into: Rely X Ultimate- shaped pin (ULT-M), ULT- accessory pin (ULT-A), ULT- Splendor SAP (ULT-S), Rely X U200 (U200-M), U200-A and U200-S. The specimens were sectioned (cervical, middle and apical thirds) and submitted to the push-out test using the universal testing machine EMIC DL200MF. The data obtained were submitted to the Kolmogorov-Smirnov test, and later to the analysis of variance (ANOVA), complemented by the Student-Newman-Kells (SNK) multiple comparison test. The proportions of the type of failure were compared using the Z test. The significance level was 5% for all tests. The interaction Rely-X U200 and Splendor SAP System was the only group with no statistically significant difference, in all thirds. With the use of the Rely-X U200, the modeled retainer performed better in the middle third. The lowest bond values were in the apical region. The use of accessory retainers promoted adequate values in the cervical and middle thirds. For Rely-X Ultimate, the modeled retainer had the lowest strength values. The same happened with the middle and apical third of the group with accessory pins. There is an influence of luting agents and posts systems on bond strength values. The failure pattern is directly related to the retention system*luting agents*root third interaction. El objetivo de este estudio es comparar el efecto de los sistemas de retención intrarradicular y del agente de cementación sobre la fuerza de adhesión. Se utilizaron 30 dientes de bovino no enraizados. Los especímenes se agruparon aleatoriamente en: Rely X Ultimate- pasador modelado (ULT-M), ULT- pasador accesorio (ULT-A), ULT- Splendor SAP (ULT-S), Rely X U200 (U200-M), U200-A y U200-S. Las muestras se seccionaron (tercios cervical, medio y apical) y se sometieron a la prueba de empuje con la máquina de ensayo universal EMIC DL200MF. Los datos obtenidos se sometieron a la prueba de Kolmogorov-Smirnov y, posteriormente, al análisis de la varianza (ANOVA), complementado con la prueba de comparaciones múltiples de Student-Newman-Kells (SNK). Las proporciones del tipo de fallo se compararon mediante la prueba Z. El nivel de significación fue del 5% para todas las pruebas. La interacción Rely-X U200 y el sistema SAP Splendor fue el único grupo sin diferencias estadísticamente significativas, en todos los tercios. Con el uso de Rely-X U200, el retenedor modelado presentó un mejor rendimiento en el tercio medio. Los valores de unión más bajos se encontraban en la región apical. El uso de retenedores accesorios proporcionó valores adecuados en los tercios cervical y medio. Para el Rely-X Ultimate, el retenedor modelado obtuvo los valores más bajos de resistencia. Lo mismo ocurrió en los tercios medio y apical del grupo con clavijas accesorias. Se puede concluir que existe una influencia de los agentes de cementación y de los sistemas de retención en los valores de resistencia de la adhesión. El patrón de fallo está directamente relacionado con la interacción sistema de retención*agente cementante*tercera. Este estudo teve por objetivo comparar o efeito dos sistemas de retenção intra-radicular e o agente cimentante na resistência de união. Foram utilizados trinta dentes bovinos unirradiculares. Os corpos-de-prova foram randomicamente agrupados em: Rely X Ultimate- pino modelado (ULT-M), ULT- pino acessório (ULT-A), ULT- Splendor SAP (ULT-S), Rely X U200 (U200-M), U200-A e U200-S. Os espécimes foram seccionados (terços cervical, médio e apical), e submetidos ao teste de push-out través da máquina de ensaio universal EMIC DL200MF. Os dados obtidos foram submetidos ao teste de Kolmogorov-Smirnov, e posteriormente a análise de variância (ANOVA), complementada pelo teste de comparações múltiplas de Student-Newman-Kells (SNK). O as proporções do tipo de falha foram comparadas pelo teste Z. O nível de significância foi de 5% para todos os testes. A interação Rely-X U200 e Sistema Splendor SAP foi o único grupo sem diferença estatística significativa, em todos os terços. Com a utilização do Rely-X U200, o retentor modelado apresentou melhor desempenho no terço médio. Os menores valores de união foram na região apical. A utilização de retentores acessórios promoveu adequados valores nos terços cervicais e médio. Para o Rely-X Ultimate, o retentor modelado obteve os menores valores de resistência. O mesmo ocorreu com o terço médio e apical do grupo com pinos acessórios. Conclui-se que há influência dos agentes cimentantes e dos sistemas de retenção nos valores de resistência de união. O padrão de falha está diretamente relacionado com a interação sistema de retenção*agente cimentantes*terço.
- Published
- 2022
4. Fracture resistance to fixed partial denture abutments with direct and indirect posts
- Author
-
Luanne Mara Rodrigues de Matos, Marcelo Lopes Silva, Lucas Portela Oliveira, Thais Oliveira Cordeiro, Wilkens Aurélio Buarque e Silva, and Paulo Isaias Seraidarian
- Subjects
Técnica de perno muñón ,Dental prosthesis ,Prosthesis failure ,Técnica para retentor intrarradicular ,Odontología ,Diseño de prótesis ,Prosthesis design ,Odontologia ,Prótesis dental ,Prótese dentária ,Falla de prótesis ,Desenho de prótese ,Falha de prótese ,Dentistry ,General Earth and Planetary Sciences ,Post and core technique ,General Environmental Science - Abstract
The objective of this study was to evaluate the resistance to fracture of three-element fixed partial dentof glasstment teeth restored with glass fiber posts (GFP) and cast post-and-core (CPC) retainers. Herein, 60 bovine mandibular incisors were divided into two groups (n = 30) according to the retainer type in: 1) resin composite core reinforced with GFP; and II) CPC (Cu-Al). Each pair of roots consisted of one sample, simulating a three-element fixed partial denture. The structures of the fixed three-element partial dentures were made in Ni-Cr alloy. A conventional dual resin cement (RelyX ARC - 3M Espe, USA) was used for all cementation procedures. Samples were subjected to a compressive load onto an orifice at occlusal contact region of the pontic until collapse or fracture. Normal data distribution was verified by D'Agostino & Pearson normality test. Unpaired t test was used for data analysis (α = 5%). The results showed that the the three-element fixed partial denture abutment teeth restored with composite resin cores retained by GFP presented higher fracture resistance compared to the ones restored with CPC (p=0.0009). In conclusion, the resistance to fracture of three-element fixed partial denture restored with resin composite core reinforced with glass fiber posts was higher to the one restored with post-and-core retainers. El objetivo de este estudio fue evaluar la resistencia a la fractura de prótesis parciales fijas de tres elementos restauradas con postes de fibra de vidrio (GFP) y muñones de metal colado (CPC). En este trabajo se dividieron 60 incisivos inferiores bovinos en dos grupos (n = 30) según el tipo de retenedor: 1) núcleo de resina compuesta reforzado con GFP; y II) CPC (Cu-Al). Cada par de raíces consistió en una muestra, simulando una prótesis parcial fija de tres elementos. Las estructuras de las prótesis parciales fijas de tres elementos fueron fabricadas con aleación de Ni-Cr. Se utilizó un cemento de resina dual convencional (RelyX ARC - 3M Espe, USA) para todos los procedimientos de cementación. Las muestras se sometieron a una carga de compresión en un orificio en la región de contacto oclusal del póntico hasta su colapso o fractura. La distribución normal de los datos se verificó mediante la prueba de normalidad de D'Agostino & Pearson. Se utilizó la prueba t no pareada para el análisis de datos (α = 5%). Los resultados mostraron que los dientes pilares de prótesis parcial fija de tres elementos restaurados con núcleos de resina compuesta retenidos con GFP mostraron una mayor resistencia a la fractura en comparación con los restaurados con CPC (p = 0,0009). En conclusión, la resistencia a la fractura de una prótesis parcial fija de tres elementos restaurada con un núcleo de resina compuesta reforzada con postes de fibra de vidrio fue superior a la restaurada con postes y retenedores de muñones. O objetivo deste estudo foi avaliar a resistência à fratura de próteses parciais fixas de três elementos restaurados com pinos de fibra de vidro (GFP) e núcleos metálicos fundidos (CPC). Neste trabalho, 60 incisivos inferiores bovinos foram divididos em dois grupos (n = 30) de acordo com o tipo de retentor: 1) núcleo de resina composta reforçada com GFP; e II) CPC (Cu-Al). Cada par de raízes consistiu em uma amostra, simulando uma prótese parcial fixa de três elementos. As estruturas das próteses parciais fixas de três elementos foram confeccionadas em liga de Ni-Cr. Um cimento resinoso dual convencional (RelyX ARC - 3M Espe, EUA) foi usado para todos os procedimentos de cimentação. As amostras foram submetidas a uma carga compressiva em um orifício na região de contato oclusal do pôntico até seu colapso ou fratura. A distribuição normal dos dados foi verificada pelo teste de normalidade de D'Agostino & Pearson. O teste t não pareado foi usado para análise dos dados (α = 5%). Os resultados mostraram que os dentes pilares de prótese parcial fixa de três elementos restaurados com núcleos de resina composta retidos por GFP apresentaram maior resistência à fratura quando comparados aos restaurados com CPC (p=0,0009). Em conclusão, a resistência à fratura de prótese parcial fixa de três elementos restaurada com núcleo de resina composta reforçada com pinos de fibra de vidro foi superior à restaurada com retentores pino e núcleo.
- Published
- 2022
5. Intraradicular fiberglass posts: comparison among different techniques for restoring flared roots
- Author
-
Thales Lara Rabelo, Alberto Nogueira da Gama Antunes, Daniel Sousa Pardini, Rodrigo de Castro Albuquerque, Carolina Bosso André, Hans Hatner Araujo Oliveira, and Paulo Isaias Seraidarian
- Subjects
Compressive Strength ,Dental prosthesis ,Health teaching ,Prótesis Dental ,Técnica de Perno Muñón ,Técnica para Retentor Intrarradicular ,Ensino em saúde ,CAD-CAM ,Prótese dentária ,Restauración Dental Permanente ,Fuerza Compresiva ,Permanent dental restoration ,Restauração Dentária Permanente ,General Earth and Planetary Sciences ,Força Compressiva ,Enseñanza en la salud ,General Environmental Science ,Post and Core Technique - Abstract
This in vitro study aimed to analyze the fracture strength and failure pattern of flared bovine roots restored with different intraradicular fiber posts and core materials, without a ferrule. To conduct this study fifty bovine incisor roots were treated endodontically, and divided into five groups (n=10), according to the following fiber post techniques and core materials: prefabricated fiberglass post and full-body bulk-fill resin composite (PF-BF); prefabricated fiberglass post and dual function resin cement (PF-RC); direct anatomic post and full-body bulk-fill resin composite (AP-BF); CAD-CAM integrated fiberglass post-and-core (CAD-PC); and adjustable fiberglass post and full-body bulk-fill resin composite (AD-BF). Intraradicular fiber posts were cemented with dual functional resin cement (Allcem Core, FGM), restored with CAD-CAM composite crowns (Brava, FGM), and subjected to loading. The data were analyzed by generalized linear models (p
- Published
- 2022
6. El uso de endodoncia guiada para la extracción de pin de fibra de vidrio: reporte de caso clínico
- Author
-
Chaves, Hebertt Gonzaga dos Santos, Assis, Stenio Teixeira, Macedo, Isabella Figueiredo Assis, Figueiredo, Barbara, Casadei, Bruna de Athayde, and Valadares, Ana Carolina Trindade
- Subjects
Ensino ,Calcificação do dente ,Teaching ,Técnica para retentor intrarradicular ,Técnica de retenedor intrarradicular ,Endodoncia ,Endodontia ,Post and core technique ,Calcificación dental ,Tooth Calcification ,Enseñanza ,Endodontics - Abstract
The use of endodontic guide is a minimally invasive technique, indicated for the treatment of calcified canals, resuming the original trajectory of the canal, in cases of deviation and/or perforation, removal of fiberglass post and even guided parendodontic surgery. The use of endodontic guide currently presents good predictability, safety and speed in the treatment of complex cases, to which it will be attributed. The technique is so precise that it does not depend on the operator and can be performed by even less skilled professionals. The objective of this work was to report a clinical case of removal of a fiberglass post in element 11, due to a failure in the prosthetic treatment, using an endodontic guide (endoguide). El uso de la guía endodóntica es una técnica mínimamente invasiva, indicada para el tratamiento de conductos calcificados, recuperación del recorrido original del conducto, en casos de desviación y/o perforación, extracción de pin de fibra de vidrio e incluso cirugía endodóntica guiada. El uso de la guía endodóntica actualmente presenta buena previsibilidad, seguridad y rapidez en el tratamiento de casos complejos, en los que estará indicada. La técnica es tan precisa que es independiente del operador y puede ser realizada incluso por profesionales menos expertos. El objetivo de este trabajo fue reportar un caso clínico de retiro de un poste de fibra de vidrio en el elemento 11, por falla en el tratamiento protésico, utilizando una guía endodóntica (endoguide). A utilização da guia endodôntica, é uma técnica minimamente invasiva, indicada para tratamento de canais calcificados, retomada da trajetória original do canal, nos casos de desvio e/ou perfuração, remoção de pino de fibra de vidro e até mesmo, cirurgia parendodôntica guiada. A utilização da guia endodôntica atualmente apresenta boa previsibilidade, segurança e rapidez no tratamento de casos complexos, na qual será indicada. A técnica é tão precisa que independe do operador e pode ser executada por profissionais até mesmo menos capacitados. O objetivo desse trabalho foi relatar um caso clínico de remoção de pino de fibra de vidro no elemento 11, devido a um insucesso no tratamento protético, utilizando uma guia endodôntica (endoguide).
- Published
- 2022
7. Perspectivas actuales sobre postes de fibra de vidrio personalizados con resina compuesta: una revisión de la literatura
- Author
-
Souza, Joyce Rodrigues de, Kukulka, Elisa Camargo, Araújo, Juliani Caroline Ribeiro de, Gagliardi, Carolina Fedel, Grassi, Elisa Donária Aboucauch, Morais, Raquel Coutinho de, Pereira, Ellen Randoli, and Borges, Alexandre Luiz Souto
- Subjects
Técnica de perno muñón ,Post and core technique e composite resins ,Resinas compostas ,Dente não vital ,Non-vital tooth ,Composite resins ,Técnica para retentor intrarradicular ,Resinas compuestas ,Dientes no vitales - Abstract
Objectives: The present literature review aimed to verify in the current literature the applicability of customizing prefabricated fiberglass posts with composite resin for clinical situations. Materials and methods: A search was made in the PubMed database using the keywords: Non-vital tooth, Post and Core Technique and Composite Resins. The search was limited to the period from 2015 to 2021, of studies published in full, in English and free access. Results: 1,981 papers were obtained from PubMed, 429 from 2015 to 2021. After reading the titles and abstracts, 422 articles were excluded. In the end, 5 articles were selected, being later added 4 articles by cross-reference, totaling 9 articles. Conclusion: Custom prefabricated fiberglass posts with composite resin are a viable option for the rehabilitation of endodontically treated teeth with wide and/or fragile canals. Objetivos: La presente revisión bibliográfica tuvo como objetivo verificar en la literatura actual la aplicabilidad de la personalización de postes prefabricados de fibra de vidrio con resina compuesta para situaciones clínicas. Materiales y métodos: Se realizó una búsqueda en la base de datos PubMed utilizando las palabras clave: Diente no vital, Técnica Post y Core y Resinas Compuestas. La búsqueda se limitó al período de 2015 a 2021, de estudios publicados íntegramente en inglés y de libre acceso. Resultados: foram obtidos 1.981 artigos no PubMed, sendo 429 no período de 2015 a 2021. Após a leitura dos títulos y resumos foram excluídos 422 artigos. Ao final foram selecionados 5 artigos, sendo posteriormente acrescentado 4 artigos por referência cruzada, totalizando 9 artigos. Conclusión: Los postes de fibra de vidrio prefabricados personalizados con resina compuesta son una opción viable para la rehabilitación de dientes tratados endodónticamente con canales anchos y/o frágiles. Objetivos: A presente revisão de literatura teve por objetivo verificar na literatura atual a aplicabilidade da customização de pinos de fibra de vidro pré-fabricados com resina composta para situações clínicas. Materiais e métodos: Foi realizada uma pesquisa na base de dados PubMed utilizando as palavras-chave: Non-vital tooth, Post and Core Technique e Composite Resins. A busca foi limitada ao período de 2015 a 2021, de estudos publicados na íntegra, em inglês e acesso gratuito. Resultados: foram obtidos 1.981 artigos no PubMed, sendo 429 no período de 2015 a 2021. Após a leitura dos títulos e resumos foram excluídos 422 artigos. Ao final foram selecionados 5 artigos, sendo posteriormente acrescentado 4 artigos por referência cruzada, totalizando 9 artigos. Conclusão: Os pinos de fibra de vidro pré-fabricados customizados com resina composta são uma opção viável para reabilitação de dentes tratados endodonticamente com canal amplo e/ou frágil.
- Published
- 2022
8. Glass Fiber Post lengths and adhesive strategies to restore extensively damaged canines
- Author
-
Oscar João Klüppel Neto, Kaye Varaschin Theodorovicz, Aline Akemi Mori, Gabriela Cristina Santin, Fernanda Ferruzzi Lima, Rafael Rocha Pacheco, Daniel Sundfeld, and Núbia Inocêncya Pavesi Pini
- Subjects
Fatigue fracture ,Fratura por fadiga ,Cura Dupla de Cimentos Resinários ,Técnica de Perno Muñón ,Técnica para Retentor Intrarradicular ,Flexural strength ,Fractura por fatiga ,Curación Dual de Cementos de Resinas ,Resistencia Flexional ,General Earth and Planetary Sciences ,Resistência à Flexão ,General Environmental Science ,Post and Core Technique ,Dental bonding, dual-cure - Abstract
The aim of this study was to evaluate different post lengths and adhesive strategies for restoring extensively damaged canines. Sixty human canines were randomly distributed into two groups (n=30), according to the resin cement used: self-adhesive or conventional. Each group was further distributed into 3 groups (n=10) based on the intracanal post lengths: 5, 7.5 and 10 mm. The radicular portion was endodontically filled, the cervical third was enlarged to simulate extensive damage and the coronal portion was reconstructed with composite resin. The samples were prepared with a simulated periodontal ligament and submitted to fatigue loading (160N – 1,200,000 cycles), followed by fracture resistance testing. The results were submitted to two-way ANOVA and Tukey tests (α=5%). The assessed glass fiber post lengths have not influenced on the fracture resistance (p>0.05). However, the performance of the conventional cements was better than the self-adhesive cements when the same post length was compared (p
- Published
- 2022
9. Resistência à fratura de dentes tratados endodonticamente e restaurados com diferentes pinos de fibra em diâmetros distintos
- Author
-
Luanne Mara Rodrigues de Matos, Marcelo Lopes Silva, Thais Oliveira Cordeiro, Darlon Martins Lima, Erick Miranda Souza, Aryvelto Miranda Silva, and Paulo Isaias Seraidarian
- Subjects
Dente não Vital ,Compressive Strength ,Técnica de Perno Muñón ,Técnica para Retentor Intrarradicular ,Fraturas dos dentes ,Tooth, non vital ,Tooth fractures ,Restauración Dental Permanente ,Fuerza Compresiva ,Fracturas de los dientes ,Restauração Dentária Permanente ,General Earth and Planetary Sciences ,Diente no Vital ,Força Compressiva ,Dental Restoration, Permanent ,Post and Core Technique ,General Environmental Science - Abstract
Objective: The aim of this in vitro study was to evaluate the fracture resistance of endodontically treated teeth restored with different intraradicular posts (carbon fibers, glass, or quartz) with varying post diameters (narrow, medium, or large). Methodology: One hundred and twenty bovine incisors were endodontically treated and the post space was prepared. The teeth were classified according to distinct diameters post space [Narrow (0.91-1.49mm), Medium (1.5-2.08mm), Large (2.09mm-2.67mm)] and randomly allocated to four restorative treatments: control (CO) - without post; and glass fiber (GF), carbon (CF) or quartz (QF) posts. The posts were cemented with dual-cure resin cement (Duo Link, Bisco, Schaumburg, United States) and the coronary portion was reconstructed with dual-cure resin composite (Bis-Core, Bisco, Schaumburg, United States). Fracture resistance values (N) were analyzed by two-way ANOVA and Bonferroni test (α=0.05). Results: The carbon fiber post (CF) was mechanical behavior similar to the other evaluated posts, regardless of the diameter. The control group (without post) showed the highest values of fracture resistance (1013.8 - 1127.2 N) in relation to the groups with the different evaluated posts (236.1 - 615.1 N). Within the same material, the diameter influenced the fracture strength only of the quartz fiber post, with the highest values for diameter large. Conclusion: A larger diameter only gives greater fracture resistance for QF; CF posts have similar resistance to other posts, regardless of diameter; and for large diameter, the type of post used does not differ in fracture resistance. Objetivo: El objetivo de este estudio in vitro fue evaluar la resistencia a la fractura de dientes tratados endodónticamente restaurados con diferentes postes intrarradiculares (fibra de carbono, vidrio o cuarzo) con diferentes diámetros de poste (estrecho, mediano o grande). Metodología: Ciento veinte incisivos bovinos fueron tratados endodónticamente y se preparó el espacio del poste. Los dientes se clasificaron según distintos diámetros post espacio [Estrecho (0,91-1,49 mm), Medio (1,5-2,08 mm), Grande (2,09 mm-2,67 mm)] y asignados aleatoriamente a cuatro tratamientos restauradores: control (CO) - sin correo; y postes de fibra de vidrio (GF), carbono (CF) o cuarzo (QF). Los postes se cementaron con cemento de resina de curado dual (Duo Link, Bisco, Schaumburg, Estados Unidos) y la porción coronaria se reconstruyó con composite de resina de curado dual (Bis-Core, Bisco, Schaumburg, Estados Unidos). Los valores de resistencia a la fractura (N) se analizaron mediante ANOVA de dos vías y prueba de Bonferroni (α=0.05) Resultados: El poste de fibra de carbono (CF) tuvo un comportamiento mecánico similar a los demás postes evaluados, independientemente del diámetro. El grupo control (sin poste) presentó los mayores valores de resistencia a la fractura (1013,8 - 1127,2 N) en relación a los grupos con los diferentes postes evaluados (236,1 - 615,1 N). Dentro del mismo material, el diámetro influyó en la resistencia a la fractura únicamente del poste de fibra de cuarzo, con los valores más altos para el diámetro grande. Conclusión: A mayor diámetro solo se obtiene mayor resistencia a la fractura para QF; Los postes CF tienen una resistencia similar a otros postes, independientemente del diámetro; y para diámetro grande, el tipo de poste utilizado no difiere en la resistencia a la fractura. Objetivo: O objetivo deste estudo in vitro foi avaliar a resistência à fratura de dentes tratados endodonticamente restaurados com diferentes pinos intrarradiculares (fibras de carbono, vidro ou quartzo) com diâmetros variados (estreito, médio ou grande). Metodologia: Cento e vinte incisivos bovinos foram tratados endodonticamente e o espaço do pino foi preparado. Os dentes foram classificados de acordo com os diâmetros distintos do espaço do pino [Estreito (0,91-1,49mm), Médio (1,5-2,08mm), Grande (2,09mm-2,67mm)] e alocados aleatoriamente em quatro tratamentos restauradores: controle (CO) - sem pinos; e pinos de fibra de vidro (GF), carbono (CF) ou quartzo (QF). Os pinos foram cimentados com cimento resinoso de cura dual (Duo Link, Bisco, Schaumburg, Estados Unidos) e a porção coronária foi reconstruída com resina composta de cura dual (Bis-Core, Bisco, Schaumburg, Estados Unidos). Os valores de resistência à fratura (N) foram analisados por ANOVA a dois fatores e teste de Bonferroni (α=0,05). Resultados: O pino de fibra de carbono (CF) apresentou comportamento mecânico semelhante aos demais pinos avaliados, independente do diâmetro. O grupo controle (sem pino) apresentou os maiores valores de resistência à fratura (1013,8 - 1127,2 N) em relação aos grupos com os diferentes pinos avaliados (236,1 - 615,1 N). Dentro do mesmo material, o diâmetro influenciou a resistência à fratura apenas do pino de fibra de quartzo, com os maiores valores para diâmetro grande. Conclusão: Um diâmetro maior só confere maior resistência à fratura para QF. Os pinos CF apresentam resistência semelhante a outros pinos, independente do diâmetro. Para diâmetro grande, o tipo de pino utilizado não difere na resistência à fratura.
- Published
- 2022
- Full Text
- View/download PDF
10. REABILITAÇÃO PROTÉTICA ANTERIOR COM COROA METAL FREE E NÚCLEO DE FIBRA DE VIDRO CONFECCIONADO EM SISTEMA CAD-CAM - RELATO DE CASO.
- Author
-
Gaspar, Mariane Piccioli, De Assis Marcolino, Giovana, and De Oliveira Correa, Giovani
- Subjects
- *
GLASS fibers , *CLINICAL medicine , *REHABILITATION , *AESTHETICS , *JOINT infections - Abstract
This article describes a case report on anterior prosthetic rehabilitation with metal-free crown and fiberglass core made using CAD-CAM system. The technique of intraradicular fiberglass retainers, made by the CAD-CAM system, allows rehabilitation in cases where there is no remaining coronal structure, ensuring high retention and excellent adaptation. The clinical case presented shows that the use of the CAD-CAM system for the fabrication of fiberglass cores allows for clinically satisfactory results, promoting aesthetics, fracture resistance, and ease of clinical application. [Extracted from the article]
- Published
- 2022
- Full Text
- View/download PDF
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.