1. Comparison of ozone retrievals from the Pandora spectrometer system and Dobson spectrophotometer in Boulder, Colorado.
- Author
-
Herman, J., Evans, R., Cede, A., Abuhassan, N., Petropavlovskikh, I., and McConville, G.
- Subjects
OZONE ,SPECTROPHOTOMETERS ,CLIMATOLOGY ,TEMPERATURE ,ATMOSPHERIC ozone - Abstract
A comparison of retrieved total column ozone amounts TCO between the Pandora #34 spectrometer system and the Dobson #061 spectrophotometer from direct-sun observations was performed on the roof of the Boulder, Colorado NOAA building. This paper, part of an ongoing study, covers a one-year period starting on 17 December 2013. Both the standard Dobson and Pandora total column ozone TCO retrievals required a correction TCOcorr=TCO (1+C(T )) using the effective climatology derived ozone temperature T to remove a seasonal difference caused by using a fixed temperature in each retrieval algorithm. The respective corrections C(T ) are C
Pandora = 0.00333(T-225) and CDobson = -0.0013(T-226.7) per K. After the applied corrections removed the seasonal retrieval dependence on ozone temperature, TCO agreement between the instruments was within 1% for clear-sky conditions. For clear-sky observations, both co-located instruments tracked the day-to-day variation in total column ozone amounts with a correlation of r² = 0.97 and an average offset of 1.1±5.8 DU. In addition, the Pandora data showed 0.3% annual average agreement with satellite overpass data from AURA/OMI (Ozone Monitoring Instrument) and 1% annual average offset with Suomi-NPP/OMPS (Suomi National Polar-orbiting Partnership, the nadir viewing portion of the Ozone Mapper Profiler Suite). [ABSTRACT FROM AUTHOR]- Published
- 2015
- Full Text