2. A quality‐checked and physics‐constrained deep learning method to estimate material basis images from single‐kV contrast‐enhanced chest CT scans
- Author
-
Yinsheng Li, Xin Tie, Ke Li, Ran Zhang, Zhihua Qi, Adam Budde, Thomas M. Grist, and Guang‐Hong Chen
- Subjects
General Medicine - Published
- 2023
- Full Text
- View/download PDF
3. High Pitch Helical CT Reconstruction
- Author
-
Adam Budde, Guang-Hong Chen, Jiang Hsieh, Ke Li, Juan Montoya, Yinsheng Li, Chengzhu Zhang, and John Hayes
- Subjects
Physics ,Radiological and Ultrasound Technology ,business.industry ,Phantoms, Imaging ,Detector ,Iterative reconstruction ,Translation (geometry) ,Helical ct ,Computer Science Applications ,Filtered backprojection ,Compressed sensing ,Optics ,High pitch ,Electrical and Electronic Engineering ,business ,Artifacts ,Tomography, X-Ray Computed ,Rotation (mathematics) ,Tomography, Spiral Computed ,Software - Abstract
To avoid severe limited-view artifacts in reconstructed CT images, current multi-row detector CT (MDCT) scanners with a single x-ray source-detector assembly need to limit table translation speeds such that the pitch ${p}$ (viz., normalized table translation distance per gantry rotation) is lower than 1.5. When ${p}>{1.5}$ , it remains an open question whether one can reconstruct clinically useful helical CT images without severe artifacts. In this work, we show that a synergistic use of advanced techniques in conventional helical filtered backprojection, compressed sensing, and more recent deep learning methods can be properly integrated to enable accurate reconstruction up to ${p}={4}$ without significant artifacts for single source MDCT scans.
- Published
- 2021
4. A platform-independent method to reduce CT truncation artifacts using discriminative dictionary representations
- Author
-
Adam Budde, Yinsheng Li, Ke Li, Yang Chen, Guang-Hong Chen, and Jiang Hsieh
- Subjects
Truncation ,Image quality ,01 natural sciences ,Article ,Imaging phantom ,030218 nuclear medicine & medical imaging ,03 medical and health sciences ,DICOM ,0302 clinical medicine ,Discriminative model ,Statistics ,Image Processing, Computer-Assisted ,Humans ,0101 mathematics ,Projection (set theory) ,Retrospective Studies ,Mathematics ,Artifact (error) ,Pixel ,Phantoms, Imaging ,business.industry ,010102 general mathematics ,Pattern recognition ,General Medicine ,Artificial intelligence ,Artifacts ,Tomography, X-Ray Computed ,business ,Algorithms - Abstract
Purpose When the scan field of view (SFOV) of a CT system is not large enough to enclose the entire cross-section of the patient, or the patient needs to be positioned partially outside the SFOV for certain clinical applications, truncation artifacts often appear in the reconstructed CT images. Many truncation artifact correction methods perform extrapolations of the truncated projection data based on certain a priori assumptions. The purpose of this work was to develop a novel CT truncation artifact reduction method that directly operates on DICOM images. Materials and Methods The blooming of pixel values associated with truncation was modeled using exponential decay functions, and based on this model, a discriminative dictionary was constructed to represent truncation artifacts and non-artifact image information in a mutually exclusive way. The discriminative dictionary consists of a truncation artifact sub-dictionary and a non-artifact sub-dictionary. The truncation artifact sub-dictionary contains 1000 atoms with different decay parameters, while the non-artifact sub-dictionary contains 1000 independent realizations of Gaussian white noise that are exclusive with the artifact features. By sparsely representing an artifact-contaminated CT image with this discriminative dictionary, the image was separated into a truncation artifact-dominated image and a complementary image with reduced truncation artifacts. The artifact-dominated image was then subtracted from the original image with an appropriate weighting coefficient to generate the final image with reduced artifacts. This proposed method was validated via physical phantom studies and retrospective human subject studies. Quantitative image evaluation metrics including the relative root mean square error (rRMSE) and the universal image quality index (UQI) were used to quantify the performance of the algorithm. Results For both phantom and human subject studies, truncation artifacts at the peripheral region of the SFOV were effectively reduced, revealing soft tissue and bony structure once buried in the truncation artifacts. For the phantom study, the proposed method reduced the relative RMSE from 15% (original images) to 11%, and improved the UQI from 0.34 to 0.80. Conclusion A discriminative dictionary representation method was developed to mitigate CT truncation artifacts directly in the DICOM image domain. Both phantom and human subject studies demonstrated that the proposed method can effectively reduce truncation artifacts without access to projection data. This article is protected by copyright. All rights reserved.
- Published
- 2017
- Full Text
- View/download PDF
5. Impact of bowtie filter and object position on the two-dimensional noise power spectrum of a clinical MDCT system
- Author
-
Guang-Hong Chen, Jiang Hsieh, Ke Li, Juan P. Cruz-Bastida, Adam Budde, and Daniel Gomez-Cardona
- Subjects
Physics ,business.industry ,Orientation (computer vision) ,Image quality ,Isocenter ,General Medicine ,Iterative reconstruction ,Filter (signal processing) ,Imaging phantom ,030218 nuclear medicine & medical imaging ,03 medical and health sciences ,0302 clinical medicine ,Optics ,030220 oncology & carcinogenesis ,Symmetry (geometry) ,Image sensor ,business - Abstract
Purpose: Noise characteristics of clinical multidetector CT (MDCT) systems can be quantified by the noise power spectrum (NPS). Although the NPS of CT has been extensively studied in the past few decades, the joint impact of the bowtie filter and object position on the NPS has not been systematically investigated. This work studies the interplay of these two factors on the two dimensional (2D) local NPS of a clinical CT system that uses the filtered backprojection algorithm for image reconstruction. Methods: A generalized NPS model was developed to account for the impact of the bowtie filter and image object location in the scan field-of-view (SFOV). For a given bowtie filter, image object, and its location in the SFOV, the shape and rotational symmetries of the 2D local NPS were directly computed from the NPS model without going through the image reconstruction process. The obtained NPS was then compared with the measured NPSs from the reconstructed noise-only CT images in both numerical phantom simulation studies and experimental phantom studies using a clinical MDCT scanner. The shape and the associated symmetry of the 2D NPS were classified by borrowing the well-known atomic spectral symbols s, p, and d, which correspond to circular, dumbbell, and cloverleaf symmetries, respectively, of the wave function of electrons in an atom. Finally, simulated bar patterns were embedded into experimentally acquired noise backgrounds to demonstrate the impact of different NPS symmetries on the visual perception of the object. Results: (1) For a central region in a centered cylindrical object, an s-wave symmetry was always present in the NPS, no matter whether the bowtie filter was present or not. In contrast, for a peripheral region in a centered object, the symmetry of its NPS was highly dependent on the bowtie filter, and both p-wave symmetry and d-wave symmetry were observed in the NPS. (2) For a centered region-ofinterest (ROI) in an off-centered object, the symmetry of its NPS was found to be different from that of a peripheral ROI in the centered object, even when the physical positions of the two ROIs relative to the isocenter were the same. (3) The potential clinical impact of the highly anisotropic NPS, caused by the interplay of the bowtie filter and position of the image object, was highlighted in images of specific bar patterns oriented at different angles. The visual perception of the bar patterns was found to be strongly dependent on their orientation. Conclusions: The NPS of CT depends strongly on the bowtie filter and object position. Even if the location of the ROI with respect to the isocenter is fixed, there can be different symmetries in the NPS, which depend on the object position and the size of the bowtie filter. For an isolated off-centered object, the NPS of its CT images cannot be represented by the NPS measured from a centered object.
- Published
- 2016
- Full Text
- View/download PDF
6. Impact of bowtie filter and object position on the two-dimensional noise power spectrum of a clinical MDCT system
- Author
-
Daniel, Gomez-Cardona, Juan Pablo, Cruz-Bastida, Ke, Li, Adam, Budde, Jiang, Hsieh, and Guang-Hong, Chen
- Subjects
Phantoms, Imaging ,DIAGNOSTIC IMAGING (IONIZING AND NON-IONIZING) ,Computer Simulation ,Artifacts ,Tomography ,Algorithms - Abstract
Noise characteristics of clinical multidetector CT (MDCT) systems can be quantified by the noise power spectrum (NPS). Although the NPS of CT has been extensively studied in the past few decades, the joint impact of the bowtie filter and object position on the NPS has not been systematically investigated. This work studies the interplay of these two factors on the two dimensional (2D) local NPS of a clinical CT system that uses the filtered backprojection algorithm for image reconstruction.A generalized NPS model was developed to account for the impact of the bowtie filter and image object location in the scan field-of-view (SFOV). For a given bowtie filter, image object, and its location in the SFOV, the shape and rotational symmetries of the 2D local NPS were directly computed from the NPS model without going through the image reconstruction process. The obtained NPS was then compared with the measured NPSs from the reconstructed noise-only CT images in both numerical phantom simulation studies and experimental phantom studies using a clinical MDCT scanner. The shape and the associated symmetry of the 2D NPS were classified by borrowing the well-known atomic spectral symbols s, p, and d, which correspond to circular, dumbbell, and cloverleaf symmetries, respectively, of the wave function of electrons in an atom. Finally, simulated bar patterns were embedded into experimentally acquired noise backgrounds to demonstrate the impact of different NPS symmetries on the visual perception of the object.(1) For a central region in a centered cylindrical object, an s-wave symmetry was always present in the NPS, no matter whether the bowtie filter was present or not. In contrast, for a peripheral region in a centered object, the symmetry of its NPS was highly dependent on the bowtie filter, and both p-wave symmetry and d-wave symmetry were observed in the NPS. (2) For a centered region-ofinterest (ROI) in an off-centered object, the symmetry of its NPS was found to be different from that of a peripheral ROI in the centered object, even when the physical positions of the two ROIs relative to the isocenter were the same. (3) The potential clinical impact of the highly anisotropic NPS, caused by the interplay of the bowtie filter and position of the image object, was highlighted in images of specific bar patterns oriented at different angles. The visual perception of the bar patterns was found to be strongly dependent on their orientation.The NPS of CT depends strongly on the bowtie filter and object position. Even if the location of the ROI with respect to the isocenter is fixed, there can be different symmetries in the NPS, which depend on the object position and the size of the bowtie filter. For an isolated off-centered object, the NPS of its CT images cannot be represented by the NPS measured from a centered object.
- Published
- 2016
7. Phonation Instability Flow in Excised Canine Larynges
- Author
-
Adam L. Rieves, Ketan Surender, Adam Budde, Yu Zhang, Jack J. Jiang, and Matthew R. Hoffman
- Subjects
Excised larynx ,Larynx ,medicine.medical_specialty ,Sound Spectrography ,Time Factors ,Audiology ,Vibration ,Article ,Speech and Hearing ,Dogs ,Phonation ,Pressure ,otorhinolaryngologic diseases ,medicine ,Animals ,business.industry ,Anatomy ,LPN and LVN ,Biomechanical Phenomena ,medicine.anatomical_structure ,Otorhinolaryngology ,Vocalization, Animal ,Rheology ,business - Abstract
Disordered voices are often associated with abnormal changes in aerodynamic parameters of subglottal pressure (P(s)) and airflow. Phonation instability pressure (PIP) has been previously proposed to evaluate P(s) at the onset of chaotic phonation. We propose the concept of and measure phonation instability flow (PIF), the airflow at which phonation becomes chaotic. Phonation flow range (PFR), PIF minus phonation threshold flow (PTF), is proposed to assess the range over which normal vocal fold vibration occurs.Repeated measures with each ex vivo larynx serving as its own control.Pressure and airflow were measured at phonation onset and chaos onset in seven excised canine larynges under three experimental conditions: 0% elongation with no glottal gap; 20% elongation with no glottal gap; 20% elongation with a 3-mm posterior glottal gap. Paired t tests were performed to determine if experimental measurements differed between elongations (0% and 20%) or degrees of abduction (20% elongation with and without a 3-mm glottal gap).Both PIF and PFR were dependent on abduction but not elongation. PIP was not significantly dependent on either condition. PIF and PFR showed greater differences for abduction than either phonation threshold pressure (PTP) or PTF.PIF and PFR may be useful parameters in the experimental or clinical settings, particularly when evaluating disorders characterized by a glottal gap, such as vocal fold paralysis and presbylaryngis.
- Published
- 2012
- Full Text
- View/download PDF
8. Noise power spectrum studies of CT systems with off-centered image object and bowtie filter
- Author
-
Ke Li, Juan P. Cruz-Bastida, Daniel Gomez-Cardona, Adam Budde, Guang-Hong Chen, and Jiang Hsieh
- Subjects
Physics ,Image quality ,business.industry ,Rotational symmetry ,030218 nuclear medicine & medical imaging ,03 medical and health sciences ,Noise ,0302 clinical medicine ,Optics ,Position (vector) ,Filter (video) ,Region of interest ,030220 oncology & carcinogenesis ,Dumbbell ,Symmetry (geometry) ,business - Abstract
In previous studies of the noise power spectrum (NPS) of multi-detector CT (MDCT) systems, the image object was usually placed at the iso-center of the CT system; therefore, the bowtie filter had negligible impact on the shape of the two-dimensional (2D) NPS of MDCT. This work characterized the NPS of off-centered objects when a bowtie filter is present. It was found that the interplay between the bowtie filter and object position has significant impact on the rotational symmetry of the 2D NPS. Depending on the size of the bowtie filter, the degree of object off-centering, and the location of the region of interest (ROI) used for the NPS measurements, the symmetry of the 2D NPS can be classified as circular, dumbbell, and a peculiar cloverleaf symmetry. An anisotropic NPS corresponds to structured noise texture, which may directly influence the detection performance of certain low contrast detection tasks.
- Published
- 2016
- Full Text
- View/download PDF
9. Assessment of phase based dose modulation for improved dose efficiency in cardiac CT on an anthropomorphic motion phantom
- Author
-
Adam Budde, Brian E. Nett, and Roy A. Nilsen
- Subjects
Computer science ,business.industry ,Reconstruction algorithm ,Iterative reconstruction ,Radiation ,Imaging phantom ,Weighting ,Noise ,Image noise ,Computer vision ,Artificial intelligence ,business ,Image restoration ,Automatic exposure control - Abstract
State of the art automatic exposure control modulates the tube current across view angle and Z based on patient anatomy for use in axial full scan reconstructions. Cardiac CT, however, uses a fundamentally different image reconstruction that applies a temporal weighting to reduce motion artifacts. This paper describes a phase based mA modulation that goes beyond axial and ECG modulation; it uses knowledge of the temporal view weighting applied within the reconstruction algorithm to improve dose efficiency in cardiac CT scanning. Using physical phantoms and synthetic noise emulation, we measure how knowledge of sinogram temporal weighting and the prescribed cardiac phase can be used to improve dose efficiency. First, we validated that a synthetic CT noise emulation method produced realistic image noise. Next, we used the CT noise emulation method to simulate mA modulation on scans of a physical anthropomorphic phantom where a motion profile corresponding to a heart rate of 60 beats per minute was used. The CT noise emulation method matched noise to lower dose scans across the image within 1.5% relative error. Using this noise emulation method to simulate modulating the mA while keeping the total dose constant, the image variance was reduced by an average of 11.9% on a scan with 50 msec padding, demonstrating improved dose efficiency. Radiation dose reduction in cardiac CT can be achieved while maintaining the same level of image noise through phase based dose modulation that incorporates knowledge of the cardiac reconstruction algorithm.
- Published
- 2014
- Full Text
- View/download PDF
10. TH-CD-207B-03: How to Quantify Temporal Resolution in X-Ray MDCT Imaging?
- Author
-
Guang-Hong Chen, Jiang Hsieh, Yinsheng Li, and Adam Budde
- Subjects
Physics ,Artifact (error) ,Optics ,business.industry ,Temporal resolution ,Metric (mathematics) ,Motion (geometry) ,General Medicine ,Iterative reconstruction ,business ,Rotation (mathematics) ,Imaging phantom ,Intensity (physics) - Abstract
Purpose: In modern CT scanners, a quantitative metric to assess temporal response, namely, to quantify the temporal resolution (TR), remains elusive. Rough surrogate metrics, such as half of the gantry rotation time for single source CT, a quarter of the gantry rotation time for dual source CT, or measurements of motion artifact's size, shape, or intensity have previously been used. In this work, a rigorous framework which quantifies TR and a practical measurement method are developed. Methods: A motion phantom was simulated which consisted of a single rod that is in motion except during a static period at the temporal center of the scan, termed the TR window. If the image of the motion scan has negligible motion artifacts compared to an image from a totally static scan, then the system has a TR no worse than the TR window used. By repeating this comparison with varying TR windows, the TR of the system can be accurately determined. Motion artifacts were also visually assessed and the TR was measured across varying rod motion speeds, directions, and locations. Noiseless fan beam acquisitions were simulated and images were reconstructed with a short-scan image reconstruction algorithm. Results: The size, shape, and intensity of motion artifacts varied when the rod speed, direction, or location changed. TR measured using the proposed method, however, was consistent across rod speeds, directions, and locations. Conclusion: Since motion artifacts vary depending upon the motion speed, direction, and location, they are not suitable for measuring TR. In this work, a CT system with a specified TR is defined as having the ability to produce a static image with negligible motion artifacts, no matter what motion occurs outside of a static window of width TR. This framework allows for practical measurement of temporal resolution in clinical CT imaging systems. Funding support: GE Healthcare; Conflict of Interest: Employee, GE Healthcare.
- Published
- 2016
- Full Text
- View/download PDF
11. Evaluation of low contrast detectability performance using two-alternative forced choice method on computed tomography dose reduction algorithms
- Author
-
Jean-Baptiste Thibault, Ximiao Cao, Haifeng Wu, Roy A. Nilsen, Priti Madhav, Adam Budde, Jiang Hsieh, Paavana Sainath, Jiahua Fan, and G Yadava
- Subjects
medicine.diagnostic_test ,Iterative method ,Image quality ,Two-alternative forced choice ,Computer science ,business.industry ,Radiation dose ,Computed tomography ,Iterative reconstruction ,Radiation ,Low contrast ,medicine ,Dose reduction ,Computer vision ,Artificial intelligence ,business ,Algorithm - Abstract
Today lowering patient radiation dose while maintaining image quality in Computed Tomography has become a very active research field. Various iterative reconstruction algorithms have been designed to improve/maintain image quality for low dose patient scans. Typically radiation dose variation will result in detectability variation for low contrast objects. This paper assesses the low contrast detectability performance of the images acquired at different dose levels and obtained using different image generation algorithms via two-alterative forced choice human observer method. Filtered backprojection and iterative reconstruction algorithms were used in the study. Results showed that for the objects and scan protocol used, the iterative algorithm employed in this study has similar low contrast detectability performance compared to filtered backprojection algorithm at a 4 times lower dose level. It also demonstrated that well controlled human observer study is feasible to assess the image quality of a CT system.
- Published
- 2012
- Full Text
- View/download PDF
12. MO-FG-204-09: High Spatial Resolution and Artifact-Free CT Bone Imaging at Off-Centered Positions: An Application of Model-Based Iterative Reconstruction
- Author
-
Adam Budde, Ke Li, Guang-Hong Chen, Jiang Hsieh, and Daniel Gomez-Cardona
- Subjects
medicine.diagnostic_test ,business.industry ,Computer science ,Radiography ,Streak ,Isocenter ,Computed tomography ,Image processing ,General Medicine ,Bone imaging ,Iterative reconstruction ,Imaging phantom ,Kernel (image processing) ,medicine ,Anthropomorphic phantom ,business ,Nuclear medicine ,Image resolution - Abstract
Purpose: Although the anatomy of interest should be positioned as close as possible to the isocenter of CT scanners, off-centering may be inevitable during certain exams in clinical practice such as lumbar spine and elbow imaging. Off-centering degrades image sharpness, generates streak artifacts, and sometimes creates blooming artifacts due to truncation. The purpose of this work was to investigate whether the use of model-based image reconstruction (MBIR) can alleviate the negative impacts of off-centering to achieve high quality CT bone imaging. Methods: Both an anthropomorphic phantom and an ex vivo swine elbow sample were scanned at centered and off-centered positions using clinical CT bone scan protocols. The magnitude of off-centering was determined from localizer radiographs. Both FBP and MBIR reconstructions were performed. For FBP, both standard and Bone Plus kernels commonly used in bone imaging were used. Objective assessment of image sharpness, noise standard deviation, and noise nonuniformity were performed. Additionally, we retrospectively analyzed human subject data acquired under off-centered conditions as a validation study. Results: In FBP images of the phantom, off-centering by 10 cm led to a 14% increase in noise (p
- Published
- 2015
- Full Text
- View/download PDF
13. WE-A-301-10: How Much CT Radiation Dose Can Model Based Iterative Reconstruction (Veo) Save? - A Physical Evaluation of the Image Quality Using Standard Phantoms
- Author
-
Priti Madhav, Jiahua Fan, Paavana Sainath, Jiang Hsieh, G Yadava, Adam Budde, and A Cohen
- Subjects
Noise power ,Noise ,Contrast-to-noise ratio ,Image quality ,business.industry ,Medical imaging ,General Medicine ,Iterative reconstruction ,Nuclear medicine ,business ,Image resolution ,Imaging phantom - Abstract
Purpose: This study is a comparative evaluation between Veo, GE Healthcare's model based iterative reconstruction engine, and contemporary filtered backprojection (FBP) techniques. The purpose is to estimate Veo's ability to produce diagnostic image quality at reduced dose levels. Methods: Standard image quality metrics were measured at different dose levels using physics phantoms commonly found in clinical settings. A GE multi‐slice CT system was used to scan a CATPHAN600® phantom in order to compare the noise and signal properties of FBP and Veo; tungsten wire phantoms were used to characterize high contrastspatial resolution between the two reconstruction algorithms. Three routine clinical protocols were tested: head, adult abdomen, and pediatric. Baseline FBP dose levels for each protocol were determined by the mean noise index from a large international database of scan histories. The metrics used in this study include MTF, noise power, contrast to noise ratio, and statistical low contrast detectability. Results: All of the tested metrics showed improved performance for the Veo at equal dose. Measurement differences between full dose FBP and 1/4th dose Veo were found to be statistically insignificant, indicating similar image quality. Conclusions: Veo reconstruction produces higher image quality than FBP at all measured dose levels and has the ability to greatly reduce the dose of routine CTimaging, as observed from standard physics phantom evaluation.