204 results on '"Marek Jastrzębski"'
Search Results
2. Comparison of six risk scores for the prediction of atrial fibrillation recurrence after cryoballoon‐based ablation and development of a simplified method, the 0‐1‐2 PL score
- Author
-
Marek Jastrzębski, Grzegorz Kiełbasa, Kamil Fijorek, Adam Bednarski, Aleksander Kusiak, Tomasz Sondej, Agnieszka Bednarek, Wiktoria Wojciechowska, and Marek Rajzer
- Subjects
0‐1‐2 PL score ,cryoballoon ,atrial fibrillation ablation ,atrial fibrillation recurrence ,risk score ,Diseases of the circulatory (Cardiovascular) system ,RC666-701 - Abstract
Abstract Introduction There are several prognostic scores for the assessment of risk of atrial fibrillation (AF) recurrence post ablation procedure. However, the use of these complex scores is difficult and the validation on different populations brought divergent results. Our goal was to compare the performance of these risk scores as the basis for the development of a new, simplified score based only on few universally predictive variables. Methods All cryoballoon‐based AF ablations performed in a single‐center over a 10‐year period were prospectively analyzed with regard to AF recurrence. This served to analyze the performance of APPLE, CAAP‐AF, SCALE‐CryoAF, MB‐LATER, CHADS2, and CHA2DS2‐VASc risk scores. Results A total of 597 patients, mostly (78.1%) with paroxysmal AF were studied. Analyzed risk scores performed poorer than in the original publications because some risk factors were not predictive of AF recurrence. A simplified score named 0‐1‐2 PL, composed of just two universally predictive variables, AF type (1 point for Persistent AF) and LA dimension (1 point for LA size >45 mm) was developed. The 0‐1‐2 PL score stratified patients into low risk (0 points), intermediate risk (1 point), and high risk categories (2 points) which were related to a 2‐year risk of AF recurrence of 21%, 37%, and 55%, respectively. This score had C‐statistics (0.620) higher/comparable to other investigated much more complex scores. Conclusion The assessment of risk of AF recurrence at the pre‐ablation stage can be simplified without compromising accuracy. This could help to popularize risk assessment and standardization of AF management.
- Published
- 2021
- Full Text
- View/download PDF
3. Outcomes of atrial fibrillation ablation program based on single-shot techniques
- Author
-
Marek Jastrzębski, Grzegorz Kiełbasa, Kamil Fijorek, Adam Bednarski, Aleksander Kusiak, Tomasz Sondej, Agnieszka Bednarek, Pawel Lis, Agnieszka Olszanecka, and Marek Rajzer
- Subjects
atrial fibrillation ablation ,redo ablation ,single-shot technique ,pulmonary vein ablation catheter ,cryoballoon ,Medicine - Published
- 2020
- Full Text
- View/download PDF
4. Cryoballoon pulmonary vein isolation as a standard approach for interventional treatment of atrial fibrillation. A review and a practical guide to an effective and safe procedure
- Author
-
Grzegorz Kiełbasa and Marek Jastrzębski
- Subjects
atrial fibrillation ,cryoballoon ,ablation ,outcome ,complications. ,Medicine - Abstract
Since the cryoballoon was introduced into clinical practice, approximately half a million patients have undergone a pulmonary vein isolation (PVI) using this tool throughout the world. This single-shot technique makes the pulmonary vein isolation procedure easier and has the potential to expand access to the interventional treatment of atrial fibrillation (AF), eventually leading to a reduction of the AF-related disease burden. Several studies and metanalyses have assessed the acute and long-term efficacy of cryoballoon-based PVI. The reported success rate of PV isolation during the procedure is about 98%. Despite this, the long-term effectiveness of the procedure (AF free survival) assessed at 1 year after the ablation is in the range of 70–82%. The AF-free survival rate significantly depends on the clinical characteristics of the studied group and the presence of risk factors, especially the type of AF (paroxysmal vs. persistent), LA size and the presence of heart failure. For a safe and effective procedure the electrophysiologist should be aware of all minute details of the procedure including several tricks developed by the most experienced operators and the pre-procedural and post-procedural management recommendations. Detailed knowledge of complications of cryoballoon (CB)-based ablation is mandatory. This review concentrates on the practical aspects and recommendations for a cryoballoon ablation procedure. The review is based on the authors’ experience, including 800 procedures performed over 11 years with a low complication rate, and is presented within the context of the literature.
- Published
- 2020
- Full Text
- View/download PDF
5. Renal denervation in patients with symptomatic chronic heart failure despite resynchronization therapy – a pilot study
- Author
-
Tomasz Drożdż, Marek Jastrzębski, Paweł Moskal, Aleksander Kusiak, Agnieszka Bednarek, Katarzyna Styczkiewicz, Piotr Jankowski, and Danuta Czarnecka
- Subjects
chronic heart failure ,cardiac resynchronization therapy ,renal denervation ,Medicine - Published
- 2019
- Full Text
- View/download PDF
6. Biventricular pacing for correcting dyssynchrony that is not there or targeted pacing to restore physiology?
- Author
-
Marek Jastrzębski
- Subjects
Physiology (medical) ,Cardiology and Cardiovascular Medicine - Published
- 2023
7. Left bundle branch area pacing outcomes: the multicentre European MELOS study
- Author
-
Marek Jastrzębski, Grzegorz Kiełbasa, Oscar Cano, Karol Curila, Luuk Heckman, Jan De Pooter, Milan Chovanec, Leonard Rademakers, Wim Huybrechts, Domenico Grieco, Zachary I Whinnett, Stefan A J Timmer, Arif Elvan, Petr Stros, Paweł Moskal, Haran Burri, Francesco Zanon, Kevin Vernooy, MUMC+: MA Med Staf Artsass Cardiologie (9), Fysiologie, and RS: Carim - H06 Electro mechanics
- Subjects
Heart Failure ,Bundle of His ,Left bundle fascicular pacing ,Complications ,Bundle-Branch Block ,Cardiac Pacing, Artificial ,Conduction system pacing ,Distal capture ,Left ventricular septal pacing ,Electrocardiography ,Treatment Outcome ,Bradycardia ,Humans ,Left bundle branch pacing ,Female ,CARDIAC RESYNCHRONIZATION THERAPY ,Human medicine ,Cardiology and Cardiovascular Medicine ,Aged - Abstract
Aims Permanent transseptal left bundle branch area pacing (LBBAP) is a promising new pacing method for both bradyarrhythmia and heart failure indications. However, data regarding safety, feasibility and capture type are limited to relatively small, usually single centre studies. In this large multicentre international collaboration, outcomes of LBBAP were evaluated. Methods and results This is a registry-based observational study that included patients in whom LBBAP device implantation was attempted at 14 European centres, for any indication. The study comprised 2533 patients (mean age 73.9 years, female 57.6%, heart failure 27.5%). LBBAP lead implantation success rate for bradyarrhythmia and heart failure indications was 92.4% and 82.2%, respectively. The learning curve was steepest for the initial 110 cases and plateaued after 250 cases. Independent predictors of LBBAP lead implantation failure were heart failure, broad baseline QRS and left ventricular end-diastolic diameter. The predominant LBBAP capture type was left bundle fascicular capture (69.5%), followed by left ventricular septal capture (21.5%) and proximal left bundle branch capture (9%). Capture threshold (0.77 V) and sensing (10.6 mV) were stable during mean follow-up of 6.4 months. The complication rate was 11.7%. Complications specific to the ventricular transseptal route of the pacing lead occurred in 209 patients (8.3%). Conclusions LBBAP is feasible as a primary pacing technique for both bradyarrhythmia and heart failure indications. Success rate in heart failure patients and safety need to be improved. For wider use of LBBAP, randomized trials are necessary to assess clinical outcomes.
- Published
- 2022
8. Left bundle branch area pacing prevents pacing induced cardiomyopathy in long‐term observation
- Author
-
Agnieszka Bednarek, Grzegorz Kiełbasa, Paweł Moskal, Aleksandra Ostrowska, Adam Bednarski, Tomasz Sondej, Aleksander Kusiak, Marek Rajzer, and Marek Jastrzębski
- Subjects
General Medicine ,Cardiology and Cardiovascular Medicine - Published
- 2023
9. Right bundle branch pacing : criteria, characteristics, and outcomes
- Author
-
Marek Jastrzębski, Grzegorz Kiełbasa, Paweł Moskal, Agnieszka Bednarek, Marek Rajzer, Karol Curila, Haran Burri, and Pugazhendhi Vijayaraman
- Subjects
Physiology (medical) ,Cardiology and Cardiovascular Medicine - Abstract
BackgroundTargets for right-sided conduction system pacing (CSP) include His bundle and right bundle branch. ECG patterns, diagnostic criteria and outcomes of right bundle branch pacing (RBBP) are not known.ObjectiveOur aims were to delineate electrocardiographic and electrophysiological characteristics of RBBP and to compare outcomes between RBBP and His bundle pacing (HBP).MethodsPatients with confirmed right CSP were divided according to the conduction system potential to QRS interval at the pacing lead implantation site. Six hypothesized RBBP criteria as well as pacing parameters, echocardiographic outcomes and all-cause mortality were analyzed.ResultsAll analyzed criteria discriminated between HBP and LBBP: double QRS transition during threshold test, selective paced QRS different from conducted QRS, stimulus to selective QRS > potential-QRS, small increase in V6RWPT during QRS transition, equal capture thresholds of CSP and myocardium, and stimulus-V6R-wave peak time (V6RWPT) > potential-V6RWPT (adopted as diagnostic standard). Per this last criterion, RBBP was observed in 19.2% (64/326) patients who had been targeted for HBP, present mainly among patients with potential to QRS < 35 ms (90.6%, 48/53) and occasionally in the remaining patients (5.6%, 16/273). RBBP was characterized by longer QRS (by 10.5 ms), longer V6RWPT (by 11.6 ms) and better sensing (by 2.6 mV) compared to HBP. During median follow-up of 29 months, no differences in capture threshold, echocardiographic outcomes or mortality were found.ConclusionsRBBP is a distinct CSP modality that is frequently observed when the pacing lead is positioned more distally along the right conduction system.
- Published
- 2023
10. Anatomic, Radiologic and Electrocardiographic Considerations for Conduction System Pacing
- Author
-
Paweł Moskal and Marek Jastrzębski
- Subjects
medicine.medical_specialty ,business.industry ,Internal medicine ,Cardiology ,Medicine ,Electrical conduction system of the heart ,business - Abstract
His bundle pacing and left bundle branch pacing are complementary implantation techniques that combine into conduction system pacing, which allows maintaining or recovering physiological activation of the heart. We selected cases from the electrophysiological laboratory of the University Hospital in Krakow to present theoretical and practical aspects of conduction system pacing using fluoroscopy images, ECG and EGM recordings.
- Published
- 2021
11. Novelties in cardiac pacing. Left bundle branch pacing, a step-by-step guide
- Author
-
Marek Jastrzębski
- Subjects
medicine.medical_specialty ,Cardiac pacing ,business.industry ,Internal medicine ,Left bundle branch ,medicine ,Cardiology ,business - Abstract
Left bundle branch pacing (LBBP) technique is a new method for conduction system pacing that is useful for both bradyarrhythmia and heart failure indications. LBBP, while less physiological than His bundle pacing, offers several practical advantages. Namely, lower and stable pacing thresholds, good sensing of the intrinsic ventricular activity and easiness in localizing the pacing target. The LBBP method more often than His bundle pacing results in engagement of the conduction system distal to the area of the block. A step-by-step approach to LBBP was described. Attention was given to the following phases of the procedure: 1) localization of the target area on the septum, 2) the lead rotation technique with an interpretation of the lead responses (drill effect, screwdriver effect, entanglement effect), 3) methods for monitoring the lead depth in the septum to avoid perforation (fixation beats, continuous pace mapping, impedance), and 4) methods to differentiate between LBBP and left ventricular septal pacing.
- Published
- 2021
12. Impact of Arterial Hypertension and Use of Antihypertensive Pharmacotherapy on Mortality in Patients Hospitalized due to COVID-19: The CRACoV-HHS Study
- Author
-
Wiktoria, Wojciechowska, Michał, Terlecki, Marek, Klocek, Agnieszka, Pac, Agnieszka, Olszanecka, Katarzyna, Stolarz-Skrzypek, Marek, Jastrzębski, Piotr, Jankowski, Aleksandra, Ostrowska, Tomasz, Drożdż, Aleksander, Prejbisz, Piotr, Dobrowolski, Andrzej, Januszewicz, Marcin, Krzanowski, Maciej T, Małecki, Tomasz, Grodzicki, Reinhold, Kreutz, and Marek, Rajzer
- Subjects
Male ,COVID-19 ,Middle Aged ,Calcium Channel Blockers ,Thiazides ,Hospitalization ,Angiotensin Receptor Antagonists ,Cardiovascular Diseases ,Hypertension ,Internal Medicine ,Humans ,Female ,Hospital Mortality ,Pandemics ,Antihypertensive Agents ,Aged - Abstract
Background: Cardiovascular diseases including arterial hypertension are common comorbidities among patients hospitalized due to COVID-19. We assessed the influence of preexisting hypertension and its pharmacological treatment on in-hospital mortality in patients hospitalized with COVID-19. Methods: We studied all consecutive patients who were admitted to the University Hospital in Krakow, Poland, due to COVID-19 between March 2020 and May 2021. Data of 5191 patients (mean age 61.9±16.7 years, 45.2% female) were analyzed. Results: The median hospitalization time was 14 days, and the mortality rate was 18.4%. About a quarter of patients had an established cardiovascular disease including coronary artery disease (16.6%) or stroke (7.6%). Patients with hypertension (58.3%) were older and had more comorbidities than patients without hypertension. In multivariable logistic regression analysis, age above median (64 years), male gender, history of heart failure or chronic kidney disease, and higher C-reactive protein level, but not preexisting hypertension, were independent risk factors for in-hospital death in the whole study group. Patients with hypertension already treated (n=1723) with any first-line antihypertensive drug (angiotensin-converting enzyme inhibitors, angiotensin receptor blockers, beta-blockers, calcium channel blockers, or thiazide/thiazide-like diuretics) had a significantly lower risk of in-hospital death (odds ratio, 0.25 [95% CI, 0.2–0.3]; P Conclusions: Although the diagnosis of preexisting hypertension per se had no significant impact on in-hospital mortality among patients with COVID-19, treatment with any first-line blood pressure–lowering drug had a profound beneficial effect on survival in patients with hypertension. These data support the need for antihypertensive pharmacological treatment during the COVID-19 pandemic.
- Published
- 2022
13. The Electrical Endpoint for an Electrical Fix
- Author
-
Marek Jastrzębski
- Subjects
Pharmacology (medical) ,Cardiology and Cardiovascular Medicine - Published
- 2022
14. Physiologic Differentiation Between Selective His Bundle, Nonselective His Bundle and Septal Pacing
- Author
-
Marek Jastrzębski
- Subjects
Bundle of His ,Cardiac Catheterization ,Electrocardiography ,Physiology (medical) ,Heart Ventricles ,Cardiac Pacing, Artificial ,Humans ,Cardiology and Cardiovascular Medicine - Abstract
His bundle (HB) pacing is an increasingly popular method of physiologic ventricular pacing. The electrocardiographic hallmark of physiologic pacing is the preservation or restoration of physiologic activation times in the left ventricle-a principle of paramount diagnostic importance. The current review focuses on the differentiation between 3 possible capture types when the pacing lead is placed in the HB region: selective HB capture when only HB is activated, nonselective HB capture when there is simultaneous activation of the adjacent right ventricular septal (RVS) myocardium, and selective RVS capture when HB is not activated at all but only septal myocardium.
- Published
- 2022
15. Left bundle branch area pacing is a feasible technique for HF and bradyarrhythmia
- Author
-
Marek Jastrzębski and Robert van den Heuvel
- Published
- 2022
16. Fixation beats: A novel marker for reaching the left bundle branch area during deep septal lead implantation
- Author
-
Grzegorz Kiełbasa, Marek Jastrzębski, Pugazhendhi Vijayaraman, Paweł Moskal, Aleksander Kusiak, Marek Rajzer, Tomasz Sondej, Adam Bednarski, and Agnieszka Bednarek
- Subjects
Male ,medicine.medical_specialty ,Bundle-Branch Block ,Perforation (oil well) ,Ventricular Septum ,030204 cardiovascular system & hematology ,Pacemaker implantation ,Electrocardiography ,03 medical and health sciences ,0302 clinical medicine ,Heart Conduction System ,Heart Rate ,Physiology (medical) ,Internal medicine ,Left bundle branch ,Humans ,Medicine ,Prospective Studies ,030212 general & internal medicine ,Lead (electronics) ,Aged ,Retrospective Studies ,Fixation (histology) ,business.industry ,Cardiac Pacing, Artificial ,Cardiology ,Female ,Cardiology and Cardiovascular Medicine ,business ,Follow-Up Studies - Abstract
IntroductionOne of the challenges of left bundle branch (LBB) pacing is to place the pacing lead deep enough in the septum to obtain capture of the LBB, yet not too deep to avoid perforation. We hypothesized that the occurrence of the ectopic beats of qR/rsR’ morphology in V1 lead (fixation beats) during the lead fixation would predict that the final desired intraseptal lead depth was just reached, while the lack of fixation beats would indicate too shallow position, and need for more lead rotations.MethodsConsecutive patients during LBB pacing device implantation were analyzed retrospectively and then prospectively with respect to the occurrence of the fixation beats during each episode of lead rotation. We compared the presence of fixation beats during the lead rotation event directly before the LBB capture area depth was reached versus during the events before intermediate/unsuccessful positions.ResultsA total of 339 patients and 1278 lead rotation events were analyzed. In the retrospective phase, the fixation beats were observed in 327/339 of final lead positions and in 9/939 of intermediate lead positions (pConclusionsMonitoring fixation beats during deep septal lead deployment can facilitate the procedure and possibly increase the safety of lead implantation.
- Published
- 2021
17. Left Bundle Branch Area Pacing for Cardiac Resynchronization Therapy
- Author
-
Óscar Cano, Marek Jastrzębski, Angela Naperkowski, Dominik Beer, Parikshit S. Sharma, Faiz A. Subsposh, Alexander R. Dal Forno, ShunmugaSundaram Ponnusamy, Sudip Nanda, Paweł Moskal, Bengt Herweg, Pugazhendhi Vijayaraman, Wilson Young, and Agnieszka Bednarek
- Subjects
medicine.medical_specialty ,Ejection fraction ,Ischemic cardiomyopathy ,Left bundle branch block ,business.industry ,medicine.medical_treatment ,Cardiac resynchronization therapy ,030204 cardiovascular system & hematology ,medicine.disease ,03 medical and health sciences ,QRS complex ,0302 clinical medicine ,Internal medicine ,Heart failure ,Left bundle branch ,cardiovascular system ,Cardiology ,medicine ,In patient ,cardiovascular diseases ,030212 general & internal medicine ,business - Abstract
Objectives The aim of this study was to assess the feasibility and outcomes of left bundle branch area pacing (LBBAP) in patients eligible for cardiac resynchronization therapy (CRT) in an international, multicenter, collaborative study. Background CRT using biventricular pacing is effective in patients with heart failure and left bundle branch block (LBBB). LBBAP has been reported as an alternative option for CRT. Methods LBBAP was attempted in patients with left ventricular ejection fraction (LVEF) Results LBBAP was attempted in 325 patients, and CRT was successfully achieved in 277 (85%) (mean age 71 ± 12 years, 35% women, ischemic cardiomyopathy in 44%). QRS configuration at baseline was LBBB in 39% and non-LBBB in 46%. Procedure and fluoroscopy duration were 105 ± 54 and 19 ± 15 min, respectively. LBBAP threshold and R-wave amplitudes were 0.6 ± 0.3 V at 0.5 ms and 10.6 ± 6 mV at implantation and remained stable during mean follow-up of 6 ± 5 months. LBBAP resulted in significant QRS narrowing from 152 ± 32 to 137 ± 22 ms (p Conclusions LBBAP is feasible and safe and provides an alternative option for CRT. LBBAP provides remarkably low and stable pacing thresholds and was associated with improved clinical and echocardiographic outcomes.
- Published
- 2021
18. What is new in His bundle pacing?
- Author
-
Marek Jastrzębski
- Subjects
03 medical and health sciences ,medicine.medical_specialty ,0302 clinical medicine ,Computer science ,Internal medicine ,Bundle ,medicine ,Cardiology ,030212 general & internal medicine ,030204 cardiovascular system & hematology - Abstract
His bundle pacing was presented as the most physiological mode of ventricular pacing. In the article we describe His pacing as an alternative cardiac pacing modality both for classic indications and resynchronization candidates. On the basis of personal experience and literature data a practical, step-by-step approach to direct His bundle pacing was described. With several ECG examples various forms of His bundle pacing were illustrated. Special attention was given to diagnosis of His bundle capture / loss of His bundle capture on the basis of ECG.
- Published
- 2020
19. Electrocardiographic Analysis for His Bundle Pacing at Implantation and Follow-Up
- Author
-
Haran Burri, Marek Jastrzębski, and Pugazhendhi Vijayaraman
- Subjects
Bundle of His ,medicine.medical_specialty ,business.industry ,medicine.medical_treatment ,Cardiac Pacing, Artificial ,Cardiac resynchronization therapy ,030204 cardiovascular system & hematology ,Implantable cardioverter-defibrillator ,Electrocardiography ,03 medical and health sciences ,0302 clinical medicine ,Heart Rate ,Internal medicine ,Bundle ,medicine ,Cardiology ,Humans ,cardiovascular diseases ,030212 general & internal medicine ,business ,Follow-Up Studies ,Cardiac stimulation - Abstract
His bundle pacing (HBP) is steadily gaining interest for providing physiological cardiac stimulation. Careful analysis of the electrocardiogram (ECG) is crucial to confirm capture of conduction tissue, which is a prerequisite for successful HBP at implantation and follow-up. However, interpretation of the ECG with HBP can be challenging. This review provides the reader with practical guidance on how to best use and troubleshoot the 12-lead ECG for HBP in daily clinical practice.
- Published
- 2020
20. Increased preexcitation on electrocardiography improves accuracy of algorithms for accessory pathway localization in Wolff–Parkinson–White syndrome
- Author
-
Grzegorz Kiełbasa, Danuta Czarnecka, Paweł Moskal, Marek Jastrzębski, and Adam Bednarski
- Subjects
medicine.diagnostic_test ,Atrial pacing ,business.industry ,Accessory pathway ,Accessory Atrioventricular Bundle ,Clinical Practice ,Wolf-parkinson-white syndrome ,Electrocardiography ,Catheter Ablation ,medicine ,Humans ,Wolff-Parkinson-White Syndrome ,Cardiology and Cardiovascular Medicine ,business ,Algorithm ,Algorithms - Abstract
Background: Several electrocardiographic (ECG) algorithms have been developed for predicting accessory pathway (AP) location in Wolff–Parkinson–White syndrome. However, their accuracy may be related to the manifested degree of preexcitation on ECG. Aims: Our goal was to assess the effect of the degree of preexcitation on the accuracy of 4 traditional AP localization algorithms and to compare them with the algorithm specifically designed for ECGs with maximal preexcitation (Pambrun) Methods: The study included 300 patients who underwent successful ablation of an overt atrioventricular AP. Resting and maximally preexcited ECGs obtained during incremental atrial pacing were assessed using 4 traditional AP localization algorithms: Xie, d’Avila, Iturralde, and Taguchi. Maximally preexcited ECGs were additionally assessed with the Pambrun algorithm. We compared the precision of the algorithms to predict accurate or anatomically adjacent AP location. Results: Theoverall accuracy of traditional AP localization algorithms using resting ECG ranged between 26% and 53.7% and improved to a range of 47.3% to 69.7% when adjacent locations were accepted. When used with maximal preexcitation, all algorithms had significantly higher accuracy, with a mean improvement of 14.3 and 15.6 percentage points for precise and adjacent sites, respectively. The Pambrun algorithm for maximally preexcited ECGs had the highest precision for both accurate and adjacent locations of the APs (89.7% and 97%, respectively). Conclusions: Greater preexcitation on ECG improved the accuracy of the traditional AP localization algorithms. The algorithm designed to use maximally preexcited ECGs has the best accuracy. Maximally preexcited ECG recordings should preferably be used in clinical practice to facilitate the ablation procedure.
- Published
- 2020
21. Left bundle branch area pacing lead implantation using an uninterrupted monitoring of endocardial signals
- Author
-
Marek Jastrzębski
- Subjects
Bundle of His ,Electrocardiography ,Heart Conduction System ,Physiology (medical) ,Cardiac Pacing, Artificial ,Humans ,Ventricular Septum ,Cardiology and Cardiovascular Medicine - Abstract
An 82-year old woman with third degree atrioventricular block underwent left bundle branch area pacing (LBBAP) lead implantation
- Published
- 2022
22. Left bundle branch-optimized cardiac resynchronization therapy (LOT-CRT) : Results from an international LBBAP collaborative study group
- Author
-
Karol Curila, Paweł Moskal, Wim Huybrechts, Marek Jastrzębski, Bengt Herweg, Pugazhendhi Vijayaraman, Marek Rajzer, Parikshit S. Sharma, Praveen Sreekumar, Shunmuga Sundaram Ponnusamy, Leonard M. Rademakers, and Agnieszka Bednarek
- Subjects
medicine.medical_specialty ,genetic structures ,medicine.medical_treatment ,Cardiac resynchronization therapy ,Ventricular Function, Left ,Cardiac Resynchronization Therapy ,QRS complex ,Electrocardiography ,Physiology (medical) ,Internal medicine ,medicine ,Fluoroscopy ,Humans ,cardiovascular diseases ,Lead (electronics) ,Aged ,Aged, 80 and over ,Ejection fraction ,medicine.diagnostic_test ,Left bundle branch block ,business.industry ,Stroke Volume ,Right bundle branch block ,Middle Aged ,medicine.disease ,Treatment Outcome ,Heart failure ,Cardiology ,cardiovascular system ,Female ,Human medicine ,Cardiology and Cardiovascular Medicine ,business ,circulatory and respiratory physiology - Abstract
BACKGROUND Cardiac resynchronization therapy (CRT) based on the conventional biventricular pacing (BiV-CRT) technique sometimes results in broad QRS complex and suboptimal response. OBJECTIVE We aimed to assess the feasibility and outcomes of CRT based on left bundle branch area pacing (LBBAP, in lieu of the right ventricular lead) combined with coronary venous left ventricular pacing in an international multicenter study. METHODS LBBAP-optimized CRT (LOT-CRT) was attempted in nonconsecutive patients with CRT indications. Addition of the LBBA (or coronary venous) lead was at the discretion of the implanting physician, who was guided by suboptimal paced QRS complex, and/or on clinical grounds. RESULTS LOT-CRT was successful in 91 of 112 patients (81%). The baseline characteristics were as follows: mean age 70 +/- 11 years, female 22 (20%), left ventricular ejection fraction 28.7% +/- 9.8%, left ventricular end-diastolic diameter 62 +/- 9 mm, N-terminal pro-B-type natriuretic peptide level 5821 +/- 8193 pg/mL, left bundle branch block 47 (42%), nonspecific intraventricular conduction delay 25 (22%), right ventricular pacing 26 (23%), and right bundle branch block 14 (12%). The procedure characteristics were as follows: mean fluoroscopy time 27.3 +/- 22 minutes, LBBAP capture threshold 0.8 +/- 0.5 V @ 0.5 ms, and R-wave amplitude 10 mV. LOT-CRT resulted in significantly greater narrowing of QRS complex from 182 +/- 25 ms at baseline to 144 +/- 22 ms (P < .0001) than did BiV-CRT (170 +/- 30 ms; P < .0001) and LBBAP (162 +/- 23 ms; P < .0001). At follow-up of >= 3 months, the ejection fraction improved to 37% +/- 12%, left ventricular end-diastolic diameter decreased to 59 +/- 9 mm, N-terminal pro-B-type natriuretic peptide level decreased to 2514 +/- 3537 pg/mL, pacing parameters were stable, and clinical improvement was noted in 76% of patients (New York Heart Association class 2.9 vs 1.9). CONCLUSION LOT-CRT is feasible and safe and provides greater electrical resynchronization as compared with BiV-CRT and could be an alternative, especially when only suboptimal electrical re synchronization is obtained with BiV-CRT. Randomized controlled trials comparing LOT-CRT and BiV-CRT are needed.
- Published
- 2022
23. Occupational exposure to physicians working with a Zero-Gravity™ protection system in haemodynamic and electrophysiology labs and the assessment of its performance against a standard ceiling suspended shield
- Author
-
Joanna Domienik-Andrzejewska, Mateusz Mirowski, Marek Jastrzębski, Tomasz Górnik, Konrad Masiarek, Izabela Warchoł, and Włodzimierz Grabowicz
- Subjects
Electrophysiology ,Radiation ,Percutaneous Coronary Intervention ,Occupational Exposure ,Physicians ,Biophysics ,Hemodynamics ,Humans ,Radiation Dosage ,General Environmental Science - Abstract
A two centre clinical study was performed to analyse exposure levels of cardiac physicians performing electrophysiology and haemodynamic procedures with the use of state of the art Zero-Gravity™ radiation protective system (ZG). The effectiveness of ZG was compared against the commonly used ceiling suspended lead shield (CSS) in a haemodynamic lab. The operator’s exposure was assessed using thermoluminescent dosimeters (TLDs) during both ablation (radiofrequency ablation (RFA) and cryoablation (CRYA)) and angiography and angioplasty procedures (CA/PCI). The dosimeters were placed in multiple body regions: near the left eye, on the left side of the neck, waist and chest, on both hands and ankles during each measurement performed with the use of ZG. In total 29 measurements were performed during 105 procedures. To compare the effectiveness of ZG against CSS an extra 80 measurements were performed with the standard lead apron, thyroid collar and ceiling suspended lead shield during CA/PCI procedures. For ZG, the upper values for the average eye lens and whole body doses per procedure were 4 µSv and 16 µSv for the left eye lens in electrophysiology lab (with additionally used CSS) and haemodynamic lab (without CSS), respectively, and about 10 µSv for the remaining body parts (neck, chest and waist) in both labs. The skin doses to hands and ankles non-protected by the ZG were 5 µSv for the most exposed left finger and left ankle in electrophysiology lab, while in haemodynamic lab 150 µSv and 17 µSv, respectively. The ZG performance was 3 times (p p e − 2 Sv/Gym2 vs. 4.31 e − 2 Sv/Gym2, p = 0.016). The study results indicate that ZG performance is superior to CSS. It can be simultaneously used with the ceiling suspended lead shield to ensure the protection to the hands as long as this is not obstructive for the work.
- Published
- 2022
24. The V6-V1 interpeak interval : a novel criterion for the diagnosis of left bundle branch capture
- Author
-
Paweł Moskal, Karol Curila, Marek Rajzer, Marek Jastrzębski, Haran Burri, Agnieszka Bednarek, Grzegorz Kiełbasa, and Pugazhendhi Vijayaraman
- Subjects
Bundle of His ,medicine.medical_specialty ,Conduction system pacing ,Ventricular Septum ,Electrocardiography ,Clinical Research ,Pacing and Cardiac Resynchronization Therapy ,Heart Conduction System ,Physiology (medical) ,Internal medicine ,Left bundle branch ,Left bundle branch pacing ,Humans ,Medicine ,AcademicSubjects/MED00200 ,Left ventricular septal capture ,Receiver operating characteristic ,business.industry ,Cardiac Pacing, Artificial ,Left bundle branch capture ,Electrocardiogram ,Ventricular activation ,Cardiology ,Interval (graph theory) ,Cardiology and Cardiovascular Medicine ,business - Abstract
Aims We hypothesized that during left bundle branch (LBB) area pacing, the various possible combinations of direct capture/non-capture of the septal myocardium and the LBB result in distinct patterns of right and left ventricular activation. This could translate into different combinations of R-wave peak time (RWPT) in V1 and V6. Consequently, the V6-V1 interpeak interval could differentiate the three types of LBB area capture: non-selective (ns-)LBB, selective (s-)LBB, and left ventricular septal (LVS). Methods and results Patients with unquestionable evidence of LBB capture were included. The V6-V1 interpeak interval, V6RWPT, and V1RWPT were compared between different types of LBB area capture. A total of 468 patients from two centres were screened, with 124 patients (239 electrocardiograms) included in the analysis. Loss of LVS capture resulted in an increase in V1RWPT by ≥15 ms but did not impact V6RWPT. Loss of LBB capture resulted in an increase in V6RWPT by ≥15 ms but only minimally influenced V1RWPT. Consequently, the V6-V1 interval was longest during s-LBB capture (62.3 ± 21.4 ms), intermediate during ns-LBB capture (41.3 ± 14.0 ms), and shortest during LVS capture (26.5 ± 8.6 ms). The optimal value of the V6-V1 interval value for the differentiation between ns-LBB and LVS capture was 33 ms (area under the receiver operating characteristic curve of 84.7%). A specificity of 100% for the diagnosis of LBB capture was obtained with a cut-off value of >44 ms. Conclusion The V6-V1 interpeak interval is a promising novel criterion for the diagnosis of LBB area capture.
- Published
- 2022
25. His bundle has a shorter chronaxie than does the adjacent ventricular myocardium: Implications for pacemaker programming
- Author
-
Danuta Czarnecka, Marek Jastrzębski, Pugazhendhi Vijayaraman, Grzegorz Kiełbasa, Paweł Moskal, and Agnieszka Bednarek
- Subjects
Bundle of His ,Pacemaker, Artificial ,medicine.medical_specialty ,Chronaxie ,Heart Ventricles ,Safety margin ,030204 cardiovascular system & hematology ,Ventricular myocardium ,Electrocardiography ,03 medical and health sciences ,0302 clinical medicine ,Cardiac Conduction System Disease ,Heart Rate ,Physiology (medical) ,Internal medicine ,medicine ,Humans ,030212 general & internal medicine ,Pulse (signal processing) ,business.industry ,Cardiac Pacing, Artificial ,food and beverages ,Outcome and Process Assessment, Health Care ,Rheobase ,Cardiology ,Electrophysiologic Techniques, Cardiac ,Cardiology and Cardiovascular Medicine ,business - Abstract
Background Strength-duration curves for permanent His bundle (HB) pacing are potentially important for pacemaker programming. Objectives We aimed to calculate strength-duration curves and chronaxies of the HB and of the adjacent right ventricular (RV) working myocardium and to analyze zones of selective HB capture and battery current drain when pacing at different pulse durations (PDs). Methods Consecutive patients with permanent HB pacing were studied. The RV and HB capture thresholds were assessed at several PDs. Battery current drain and zones of selective HB capture at PDs of 0.1, 0.2, 0.4, and 1.0 ms were determined. Results In the whole group (N = 127), the HB chronaxie was shorter than the RV chronaxie. This difference was driven by patients with selective HB pacing (HB chronaxie 0.47 ms vs RV chronaxie 0.79 ms). The strength-duration curve for the HB had a lower rheobase and its steep portion started at shorter PDs, thus creating wider distance—zone of programmable selective HB pacing—between the HB and RV strength-duration curves at shorter PDs. The battery current drain was lower with pacing at PDs of 0.1–0.4 ms vs 1.0 ms. Chronaxie-adjusted PDs offered the lowest current drain. Conclusion For the first time, the strength-duration curves for permanent selective and nonselective HB pacing were determined. Selective HB capture and battery longevity can be promoted by shorter PDs (0.2 ms). Longer PDs (1.0 ms) offer greater safety margin for RV capture and may be preferable if simultaneous RV capture during HB pacing is desired.
- Published
- 2019
26. Świat uczonych w dziele Jana Amosa Komeńskiego: 'Labirynt świata i raj serca' i płynące z niego przesłanie do współczesnego świata nauki i edukacji
- Author
-
Marek Jastrzębski
- Abstract
This paper is part of the trend of reading the relevance of the works by John Amos Comenius for modern times. The author examines Labyrinth of the World and Paradise of the Heart, a unique literary work by the Czech scholar. The article aims to present the image of the world of scholars presented in the mentioned work and expose its message for the contemporary academic world. Although Comenius devoted many of his works to the project of transforming the world of academia, the examined work is rather an allegorical story criticising the condition of the scholars’ world than a project of its reform. In this article, the author chooses not to complement this critical vision with what can be learned from Comenius’ other works, and instead focuses only on the very picture of the world of scholars presented in the work under study. As a result, the author concludes that the most important message to the contemporary world of academia from Labyrinth of the World and Paradise of the Heart is a call for a moral-spiritual renewal.
- Published
- 2021
27. Prospective evaluation of the learning curve and electrical characteristics of left bundle branch area pacing
- Author
-
F.W. Prinzen, Sjoerd W. Westra, Kevin Vernooy, Bob Weijs, DW Den Uijl, M Mafi-Rad, J.G.L.M. Luermans, Dominik Linz, Luuk I.B. Heckman, Antonius Martinus Wilhelmus van Stipdonk, and Marek Jastrzębski
- Subjects
medicine.medical_specialty ,Learning curve ,business.industry ,Internal medicine ,Left bundle branch ,medicine ,Cardiology ,Cardiology and Cardiovascular Medicine ,business ,Prospective evaluation - Abstract
Background Left bundle branch area pacing (LBBAP) has recently been introduced as a physiological pacing technique with a synchronous ventricular activation. Objective To prospectively evaluate the feasibility and learning curve, as well as the electrical characteristics of LBBAP. Methods In 80 consecutive LBBAP pacemaker patients, ECG characteristics during intrinsic rhythm, RV septum pacing (RVSP) and LBBAP were evaluated. From the ECG's QRS duration and LVAT (stimulus to V6 R-wave peak time, RWPT) were measured. Also, the left bundle branch potential (LBBpot) to V6 RWPT interval was measured and compared to the LVAT. After conversion of the ECG into VCG (Kors conversion matrix), QRS area, as measurement for electrical dyssynchrony, was calculated. Results Permanent lead implantation was successful in 77/80 patients (96%) undergoing an attempt at LBBAP. LBBAP lead implantation time as well as fluoroscopy time were significantly shorter during last 25% of implantation compared to first 25% of implantations (17±5 min vs. 33±16 min and 12±7 min vs. 21±13 min, respectively, panel A and B). LBB capture was obtained in 54/80 patients (68%). In 36/45 patients (80%) with intact AV conduction and narrow QRS an LBBpot was present. The mean interval between the LBBpot and the onset of QRS was 22±6 ms. In the patients with narrow QRS (n=45), QRS duration increased significantly during both RVSP (139±24 ms) and LBBAP (123±21 ms), compared to intrinsic rhythm (95±13 ms). QRS area on the other hand, increased during both RVSP (73±20 μVs) but decreased during LBBAP (41±15 μVs), to values close to intrinsic rhythm (32±16 μVs, panel C). For all patients, QRS area was significantly lower in patients with LBB capture compared to patients without capture (43±18 μVs vs 54±21 μVs, respectively). In patients with LBB capture (n=54), LVAT was significantly shorter compared to patients without LBB capture (75±14 vs. 88±9 ms, respectively). In the patients with LBB capture, there was a significant correlation between the LBBpot – V6 RWPT and S – V6 RWPT intervals (Pearson correlation 0.739, P Conclusion LBBAP is a safe and feasible technique, with a clear learning curve that seems obtained after ± 40–60 implantations. LBB capture is obtained in two-thirds of patients. Although QRS duration remains prolonged, LBBAP largely restores ventricular electrical synchrony to values close to intrinsic (narrow QRS) rhythm. Funding Acknowledgement Type of funding sources: None.
- Published
- 2021
28. Reaching the left bundle branch pacing area within 36 heartbeats
- Author
-
Paweł Moskal and Marek Jastrzębski
- Subjects
medicine.medical_specialty ,Bundle of His ,business.industry ,Bundle-Branch Block ,MEDLINE ,Cardiac Pacing, Artificial ,Text mining ,Heart Rate ,Internal medicine ,Left bundle branch ,medicine ,Cardiology ,Humans ,Cardiology and Cardiovascular Medicine ,business - Published
- 2021
29. Link between Brugada phenocopy and myocardial ischemia: Results from the International Registry on Brugada Phenocopy
- Author
-
Sahil Agrawal, Aldo G. Carrizo, Byron H. Gottschalk, Antonio Bayés de Luna, Andrés Ricardo Pérez-Riera, Raimundo Barbosa-Barros, János Tomcsányi, Marek Jastrzębski, Adrian Baranchuk, Gregory Dendramis, and Grace Xu
- Subjects
Adult ,Male ,medicine.medical_specialty ,Myocardial ischemia ,Myocardial Ischemia ,Ischemia ,030204 cardiovascular system & hematology ,Sudden cardiac death ,Pathogenesis ,Electrocardiography ,03 medical and health sciences ,0302 clinical medicine ,Internal medicine ,medicine ,Humans ,Registries ,cardiovascular diseases ,030212 general & internal medicine ,Aged ,Brugada Syndrome ,Brugada syndrome ,Phenocopy ,business.industry ,General Medicine ,Middle Aged ,medicine.disease ,Phenotype ,Brugada ECG Pattern ,Cardiology ,Etiology ,Female ,Cardiology and Cardiovascular Medicine ,business - Abstract
Background Brugada phenocopies clinical entities that have indistinguishable electrocardiographic (ECG) patterns from true congenital Brugada syndrome. However, they are induced by other clinical circumstances such as myocardial ischemia. The purpose of our study was to examine the clinical features and pathogenesis of ischemia-induced Brugada phenocopy (BrP). Methods Data from 17 cases of ischemia-induced BrP were collected from the International Registry (www.brugadaphenocopy.com). Data were extracted from these publications and authors were contacted to provide further insight into each case. Results Of the patients included in this study, 71% were male. Mean age was 59 ± 11 years (range: 38-76). Type-1 Brugada ECG pattern occurred in 15/17 (88%) of the cases, while a type-2 Brugada ECG pattern was observed in the other 2/17 (12%). In all cases, the Brugada ECG pattern resolved upon correction of the ischemia, indicating ischemia as the inducing circumstance. No arrhythmic events have been detected acutely or during the follow-up. Reported time to resolution ranged from 2 minutes to 5 hours. Provocative challenges using sodium channel blocking agents were performed in 7/17 cases (41%), and all failed to induce a Brugada ECG pattern (BrP Class A). The remaining 10/17 cases (59%) did not undergo provocative testing due to various clinical reasons. Conclusions Myocardial ischemia is a commonly reported etiology of BrP. Importantly, this study found no association between BrP induced by myocardial ischemia and sudden cardiac death or malignant ventricular arrhythmias.
- Published
- 2019
30. Novel approach to diagnosis of His bundle capture using individualized left ventricular lateral wall activation time as reference
- Author
-
Piotr Kukla, Marek Jastrzębski, Marek Rajzer, Pugazhendhi Vijayaraman, Grzegorz Kiełbasa, Agnieszka Bednarek, Karol Curila, and Paweł Moskal
- Subjects
Bundle of His ,medicine.medical_specialty ,Receiver operating characteristic ,business.industry ,Left bundle branch block ,Heart Ventricles ,Bundle-Branch Block ,Cardiac Pacing, Artificial ,Curve analysis ,medicine.disease ,Electrocardiography ,Ventricular activation ,Physiology (medical) ,Bundle ,Internal medicine ,Cardiology ,Humans ,Medicine ,Cardiology and Cardiovascular Medicine ,business ,Lateral wall - Abstract
AimsDuring non-selective His bundle (HB) pacing, it is clinically important to confirm His bundle capture vs. right ventricular septal (RVS) capture. The present study aimed to validate the hypothesis that during HB capture left ventricular lateral wall activation time, approximated by the V6R-wave peak time (V6RWPT), will not be longer than the corresponding activation time during native conduction.MethodsConsecutive patients with permanent HB pacing were recruited; cases with abnormal His-ventricle interval or left bundle branch block were excluded. Two corresponding intervals were compared: stimulus-V6RWPT and native HBpotential-V6RWPT. Difference between these two intervals (delta V6RWPT), diagnostic of lack of HB capture, was identified using receiver operating characteristic (ROC) curve analysis.ResultsA total of 723 ECGs (219 with native rhythm, 172 with selective HB, 215 with non-selective HB, and 117 with RVS capture) were obtained from 219 patients. The native HB-V6RWPT, non-selective-, and selective-HB paced V6RWPT were nearly equal, while RVS V6RWPT was 32.0 (±9.5) ms longer. The ROC curve analysis indicated delta V6RWPT > 12 ms as diagnostic of lack of HB capture (specificity of 99.1% and sensitivity of 100%). A blinded observer correctly diagnosed 96.7% (321/332) of ECGs using this criterion.ConclusionWe validated a novel criterion for HB capture that is based on the physiological left ventricular activation time as an individualized reference. HB capture can be diagnosed when paced V6RWPT does not exceed the value obtained during native conduction by more than 12 ms, while longer paced V6RWPT indicates RVS capture.
- Published
- 2021
31. Non-algorithmic approach to accessory pathway localization based on a mobile app
- Author
-
P Moskal and Marek Jastrzębski
- Subjects
business.industry ,Polarity (physics) ,Physiology (medical) ,Mobile apps ,Medicine ,Accessory pathway ,Ecg lead ,Cardiology and Cardiovascular Medicine ,business ,Mobile device ,Neuroscience ,Atrioventricular accessory pathway - Abstract
Funding Acknowledgements Type of funding sources: Public Institution(s). Main funding source(s): Polish Cardiac Society - Section of Non-invasive Electrocardiology and Telemonitoring (PTK SENIT) Background. Electrocardiographical localization of accessory pathways (AP) in WPW syndrome remains an elusive goal. Despite several, often very complex algorithms that were developed over the last three decades, none of them is very accurate - as demonstrated by several independent validation studies. Moreover, algorithms are difficult to remember, which further limits their usefulness. The accessory pathway regions are arbitrary and transitions between them are smooth, not binary. The same applies to ECG features such as QRS polarity – they are not binary. Moreover, even the most careful ECG lead placement cannot compensate for the variability in heart position within the chest. Therefore, it is unrealistic to expect that any ECG feature or feature set will precisely identify a particular location in a 0 vs. 1 fashion. Aim We intend to create a mobile app / web based localizing application, that would support a novel method for AP localization: a colour density map generator - based on actual distribution of a sizable number of accessory pathway with a particular QRS features. Methods A total of 881 consecutive AP ablation procedures were reviewed and patients with successful ablation of an overt accessory pathway were included. ECG with baseline and full preexcitation obtained during incremental atrial pacing were obtained. AP localization was based on stored fluoroscopic images in several projections and procedure description. Each AP localization, as well as QRS polarity in all 12 leads, separately for full and baseline preexcitation patterns, were coded and introduced into the application database. An application web-based, optimized for mobile devices was developed. This application enabled to graphically show changing localization of AP with regard to the introduced, at each step, QRS polarity in a particular ECG lead. User can choose his/her own steps or criteria; there is no need to adhere to the proposed steps. Results A total of 604 patients/ ECGs were available for density map generation. With each additional lead QRS information introduced into the application the user can appreciate more and more precise localization of the AP. This quickly enables to pinpoint the area of maximum probability, i.e. the most likely/frequent location, followed by the immediate adjacent locations. Representative screen shots of to typical inital steps for left- and right-sided APs are provided below (Figure 1 and Figure 2). Limited prospective assessment was very favourable. Conclusions A novel method, easy to use, not requiring to remember any algorithmic steps, and based on an analysis of by far the largest cohort of over accessory pathways (in comparison with published algorithms) was developed. Prospective validation of the localization application seems warranted. Abstract Figure.
- Published
- 2021
32. Novel Criterion to Diagnose Left Bundle Branch Capture in Patients With Left Bundle Branch Block
- Author
-
Marek Jastrzębski and Pugazhendhi Vijayaraman
- Subjects
Bundle of His ,Left bundle branch block ,business.industry ,Heart Conduction System ,Left bundle branch ,Bundle-Branch Block ,medicine ,Humans ,In patient ,Arrhythmias, Cardiac ,Anatomy ,medicine.disease ,business - Published
- 2021
33. Subcutaneous implantable cardioverter-defibrillator and the two-incision intermuscular technique in pediatric patients : a single center experience
- Author
-
Marek Jastrzębski, Sebastian Góreczny, Joachim Winter, Maciej Pitak, Anna Rudek-Budzyńska, and Piotr Weryński
- Subjects
medicine.medical_specialty ,business.industry ,medicine.medical_treatment ,MEDLINE ,Single Center ,Implantable cardioverter-defibrillator ,Surgery ,Defibrillators, Implantable ,Prosthesis Implantation ,Treatment Outcome ,medicine ,Humans ,Cardiology and Cardiovascular Medicine ,business ,Child - Published
- 2021
34. Nonselective versus selective His bundle pacing : an acute intrapatient speckle-tracking strain echocardiographic study
- Author
-
Marek Rajzer, Grzegorz Kiełbasa, Agnieszka Bednarek, Marek Jastrzębski, Oana Ionita, Hana Línková, Paweł Moskal, Karol Curila, Radka Prochazkova, and Jana Veselá
- Subjects
Male ,medicine.medical_specialty ,Bundle of His ,Longitudinal strain ,Speckle tracking strain ,030204 cardiovascular system & hematology ,03 medical and health sciences ,Basal (phylogenetics) ,0302 clinical medicine ,Physiology (medical) ,Internal medicine ,Medicine ,Humans ,030212 general & internal medicine ,Aged ,Ejection fraction ,Strain (chemistry) ,business.industry ,Cardiac Pacing, Artificial ,Peak systolic strain ,Stroke Volume ,medicine.anatomical_structure ,Ventricle ,Echocardiography ,Bundle ,Cardiology ,Ventricular Function, Right ,Cardiology and Cardiovascular Medicine ,business - Abstract
Introduction We aimed to compare the acute differences in left ventricular (LV) function and mechanical synchrony during nonselective His bundle pacing (ns-HBP) versus selective His bundle pacing (s-HBP) using strain echocardiography. Methods and results Consecutive patients with permanent His bundle pacing, in whom it was possible to obtain both s-HBP and ns-HBP, were studied in two centers. In each patient, echocardiography was performed sequentially during s-HBP and ns-HBP. Speckle-tracking echocardiography parameters were analyzed: Global longitudinal strain (GLS), the time delay between peak systolic strain in the basal septal and basal lateral segments (BS-BL delay), peak strain dispersion (PSD) and strain delay index. Right ventricle function was assessed using tricuspid annular plane systolic excursion (TAPSE) and tissue Doppler velocity of the lateral tricuspid annulus (S'). A total of 69 patients (age: 75.6 ± 10.5 years; males: 75%) were enrolled. There were no differences in LV ejection fraction and GLS between s-HBP and ns-HBP modes: 59% versus 60%, and -15.6% versus -15.7%, respectively; as well as no difference in BS-BL delay and strain delay index. The PSD value was higher in the ns-HBP group than in the s-HBP group with the most pronounced difference in the basal LV segments. No differences in right ventricular function parameters (TAPSE and S') were found. Conclusion The ns-HBP and s-HBP modes seem comparable regarding ventricular function. The dyssynchrony parameters were significantly higher during ns-HBP, however, the difference seems modest and clarification of its impact on LV function requires a larger long-term study.
- Published
- 2021
35. Left Bundle Branch Area Pacing for CRT in RBBB: Results from International LBBAP Collaborative-Study Group
- Author
-
Óscar Cano, Bengt Herweg, Dominik Beer, Gaurav A. Upadhyay, Kenneth A. Ellenbogen, Shunmuga Sundaram, Faiz A. Subzposh, Pugazhendhi Vijayaraman, Roderick Tung, Neil Patel, Santosh K. Padala, Manuel Molina-Lerma, Zachary I. Whinnett, Grzegorz Kiełbasa, Marek Jastrzębski, Parikshit S. Shanrma, Agnieska Bednarek, and Joseph Y.S. Chan
- Subjects
medicine.medical_specialty ,Ejection fraction ,Ischemic cardiomyopathy ,business.industry ,medicine.medical_treatment ,Cardiac resynchronization therapy ,Right bundle branch block ,medicine.disease ,QRS complex ,Internal medicine ,Heart failure ,Left bundle branch ,cardiovascular system ,Cardiology ,Medicine ,cardiovascular diseases ,Implant ,business - Abstract
Background: Cardiac resynchronization therapy (CRT) using biventricular pacing (BVP) has limited efficacy in patients with heart failure (HF) and right bundle branch block (RBBB). Left bundle branch area pacing (LBBAP) has been reported as an alternative option for BVP-CRT. The aim of the study was to assess the feasibility and outcomes of LBBAP in patients with RBBB and indication for CRT in an international, multicenter, collaborative study. Methods: LBBAP was attempted in patients with LVEF
- Published
- 2021
36. Patent foramen ovale and left atrial appendage flow velocity predict atrial fibrillation recurrence post cryoballoon ablation
- Author
-
Agnieszka Olszanecka, Aleksander Kusiak, Marek Rajzer, Adam Bednarski, Wiktoria Wojciechowska, Marek Jastrzębski, Tomasz Sondej, Agnieszka Bednarek, and Grzegorz Kiełbasa
- Subjects
medicine.medical_specialty ,medicine.medical_treatment ,Foramen Ovale, Patent ,030204 cardiovascular system & hematology ,Pulmonary vein ,03 medical and health sciences ,0302 clinical medicine ,Left atrial ,Internal medicine ,Atrial Fibrillation ,medicine ,Humans ,Atrial Appendage ,Heart Atria ,Cryoballoon ablation ,Survival analysis ,Mitral regurgitation ,business.industry ,Atrial fibrillation ,Middle Aged ,medicine.disease ,Ablation ,Patent foramen ovale ,Cardiology ,Cardiology and Cardiovascular Medicine ,business ,Echocardiography, Transesophageal - Abstract
Background: Transesophageal echocardiography (TEE) allows detailed characterization of atrial fibrillation (AF) substrate and could be valuable for predicting pulmonary vein isolation (PVI) procedure outcomes. Aims: We aimed at assessing the value of TEE-derived left atrial (LA) and LA appendage (LAA) features as prognostic markers for AF recurrence after cryoballoon-based ablation. Methods: Patients were enrolled using a prospective database of consecutive PVI procedures performed over a 7-year period. The following TEE-derived parameters were investigated: LAA emptying flow velocity (LAA-FV), the presence of patent foramen ovale (PFO), LA spontaneous echo contrast, and mitral regurgitation. Diagnosis of AF recurrence was based on scheduled and symptoms triggered ECG monitoring. The Cox’s regression model and Kaplan-Meier survival curves were applied for statistical analysis. Results: A total of 417 consecutive patients who underwent their first PVI using cryoballoon were analyzed (mean age: 59 years). AF recurrence was noted in 25.7% of patients (median follow-up of 24 months). Four TEE-derived variables had predictive values for AF recurrence: LAA-FV
- Published
- 2021
37. Physiology-based electrocardiographic criteria for left bundle branch capture
- Author
-
Marek Rajzer, Marek Jastrzębski, Grzegorz Kiełbasa, Paweł Moskal, Pugazhendhi Vijayaraman, Agnieszka Bednarek, and Karol Curila
- Subjects
Qrs morphology ,Male ,medicine.medical_specialty ,Bundle of His ,Bundle-Branch Block ,030204 cardiovascular system & hematology ,03 medical and health sciences ,QRS complex ,Electrocardiography ,0302 clinical medicine ,Narrow qrs ,Heart Conduction System ,Heart Rate ,Physiology (medical) ,Internal medicine ,Left bundle branch ,medicine ,Humans ,In patient ,cardiovascular diseases ,030212 general & internal medicine ,Aged ,Left bundle branch block ,business.industry ,Cardiac Pacing, Artificial ,Right bundle branch block ,medicine.disease ,medicine.anatomical_structure ,Ventricle ,Left ventricular myocardium ,Cardiology ,Female ,Cardiology and Cardiovascular Medicine ,business - Abstract
BackgroundDuring left bundle branch (LBB) area pacing, it is important to confirm that the capture of the LBB is achieved, not just the capture of only the adjacent left ventricular myocardium (LV septal capture). Our aim was to establish ECG criteria for LBB capture by analyzing ECGs with confirmed LBB capture and non-capture. We hypothesized that since LBB pacing results in physiologic depolarization of the left ventricle then the native QRS can serve as a reference for the diagnosis of LBB capture in the same patient.MethodsOnly patients with direct evidence of LBB capture (output-dependent or refractoriness-dependent QRS morphology transition) were included. Several QRS characteristics were compared between the native rhythm and different types of LBB area capture. Receiver-operator characteristics analysis was performed to determine the optimal V6 R-wave peak time (RWPT) cut-off for LBB diagnosis.ResultsA total of 357 ECG tracing (124 patients) were analyzed: 118 with native rhythm, 124 with non-selective LBB capture, 69 with selective LBB capture and 46 with LV septal capture. Our hypotheses that during LBB capture the paced V6 RWPT (measured from QRS onset) equals the native V6 RWPT and that the paced V6 RWPT (measured from the stimulus) equals the LBB potential to V6 R-wave peak interval were positively validated. Criteria based on these rules had sensitivity and specificity of 98.0–88.2% and 85.7–95.4%, respectively. The optimal and 100% specific V6 RWPT values for differentiation between LBB capture and LV septal capture in patients with narrow QRS / right bundle branch block were 83 ms and 74 ms, respectively; while in patients with left bundle branch block/asystole/ventricular escape the optimal and 100% specific V6 RWPT values were 101 ms and 80 ms, respectively.ConclusionsNovel criteria for LBB capture were developed and optimal V6 RWPT cut-offs were determined.What this study addsWe showed that LBB pacing truly reproduce the physiological depolarization of the left ventricle since the paced V6 RWPT equals the native conduction V6 RWPT.Individualized LBB capture criteria, that use the native QRS as a reference, were developed.The optimal V6 RWPT values for differentiation between LBB capture and LV septal capture were determined, separately for patients with healthy and diseased LBB.
- Published
- 2020
38. B-AB09-01 THE LEFT BUNDLE BRANCH PACING COMPARED TO LEFT BUNDLE BRANCH AREA PACING INCREASES INTERVENTRICULAR DYSSYNCHRONY BUT ACCELERATES LEFT VENTRICULAR LATERAL WALL DEPOLARIZATION
- Author
-
Pavel Jurák, Frits W. Prinzen, Radovan Smisek, Luuk I.B. Heckman, Josef Halamek, Karol Curila, Paweł Moskal, Marketa Susankova, Lucie Znojilova, Kevin Vernooy, Petr Waldauf, Vlastimil Vondra, Jakub Karch, Filip Plesinger, Marek Jastrzębski, Ivo Viscor, Pavel Osmancik, and Pavel Leinveber
- Subjects
medicine.medical_specialty ,business.industry ,Physiology (medical) ,Internal medicine ,Left bundle branch ,Cardiology ,Medicine ,Depolarization ,Interventricular dyssynchrony ,Cardiology and Cardiovascular Medicine ,business ,Lateral wall - Published
- 2021
39. Shambhala as a Sacred Place: the Central Point of the Nothing Sacred Series Universe
- Author
-
Marek Jastrzębski
- Subjects
Literature ,business.industry ,media_common.quotation_subject ,Context (language use) ,Art ,Meaning (philosophy of language) ,Nothing ,Similarity (psychology) ,Narrative ,Fantasy ,Comparative religion ,business ,Universe (mathematics) ,media_common - Abstract
This article examines the duology of Elizabeth Ann Scarborough, consisting of the novels Nothing Sacred andLast Refuge. The paper aims to present the function of the literary Shambhala in the context of the space-timemodel of the world presented by the books under study. Based on Mircea Eliade’s comparative religion theory,the author puts forward and attempts to prove the hypothesis of a far-reaching similarity between the function ofScarborough’s Shambhala in the narrative universe and the meaning of a sacred place in the archaic, religiousmodel of reality.
- Published
- 2020
40. Selective and nonselective His bundle pacing unmasks pathological Q waves on the electrocardiogram
- Author
-
Rafał Baranowski, Grzegorz Kiełbasa, Agnieszka Bednarek, Paweł Moskal, Marek Jastrzębski, and Marek Rajzer
- Subjects
medicine.medical_specialty ,Bundle of His ,Cardiac pacing ,medicine.diagnostic_test ,business.industry ,Cardiac Pacing, Artificial ,Arrhythmias, Cardiac ,Electrocardiography ,medicine.anatomical_structure ,CARDIAC THERAPY ,Internal medicine ,Bundle ,Cardiology ,Medicine ,Humans ,Cardiology and Cardiovascular Medicine ,business ,Pathological - Published
- 2020
41. Permanent left bundle branch pacing : what is the mechanism of divergent responses during programmed stimulation?
- Author
-
Marek Jastrzębski
- Subjects
Programmed stimulation ,Refractory period ,business.industry ,Physiology (medical) ,Left bundle branch ,Medicine ,Cardiology and Cardiovascular Medicine ,business ,Neuroscience ,Mechanism (sociology) - Published
- 2020
42. Both selective and nonselective His bundle, but not myocardial, pacing preserve ventricular electrical synchrony assessed by ultra-high-frequency ECG
- Author
-
Ivo Viscor, Petr Widimsky, Radovan Smisek, Karol Curila, Jana Veselá, Josef Halamek, Danuta Czarnecka, Pavel Jurák, Pavel Leinveber, Radka Prochazkova, Marek Jastrzębski, Ondrej Sussenbek, Dalibor Herman, Pavel Osmancik, Petr Stros, Paweł Moskal, Filip Plesinger, and Petr Waldauf
- Subjects
Bradycardia ,Male ,medicine.medical_specialty ,Bundle of His ,Heart Ventricles ,Bundle-Branch Block ,Mean QRS Duration ,030204 cardiovascular system & hematology ,Ventricular Function, Left ,03 medical and health sciences ,QRS complex ,Electrocardiography ,0302 clinical medicine ,Heart Rate ,Physiology (medical) ,Internal medicine ,medicine ,Humans ,cardiovascular diseases ,030212 general & internal medicine ,Ventricular dyssynchrony ,Aged ,medicine.diagnostic_test ,Bundle branch block ,business.industry ,Cardiac Pacing, Artificial ,Depolarization ,medicine.disease ,Bundle ,Cardiology ,Ventricular Function, Right ,Female ,medicine.symptom ,Cardiology and Cardiovascular Medicine ,business - Abstract
Right ventricular myocardial pacing leads to nonphysiological activation of heart ventricles. Contrary to this, His bundle pacing preserves their fast activation. Ultra-high-frequency electrocardiography (UHF-ECG) is a novel tool for ventricular depolarization assessment.The purpose of this study was to describe UHF-ECG depolarization patterns during myocardial and His bundle pacing.Forty-six patients undergoing His bundle pacing to treat bradycardia and spontaneous QRS complexes without bundle branch block were included. UHF-ECG recordings were performed during spontaneous rhythm, pure myocardial para-Hisian capture, and His bundle capture. QRS duration, QRS area, depolarization time in specific leads, and the UHF-ECG-derived ventricular dyssynchrony index were calculated.One hundred thirty-three UHF-ECG recordings were performed in 46 patients (44 spontaneous rhythm, 28 selective His bundle, 43 nonselective His bundle, and 18 myocardial capture). The mean QRS duration was 117 ms for spontaneous rhythm, 118 ms for selective, 135 ms for nonselective, and 166 ms for myocardial capture (P.001 for nonselective and myocardial capture compared to each of the other types of ventricular activation). The calculated dyssynchrony index was shortest during spontaneous rhythm (12 ms; P = .02 compared to selective and P = .09 compared to nonselective), and it did not differ between selective and nonselective His bundle capture (16 vs 15 ms; P.99) and was longest during myocardial capture of the para-Hisian area (37 ms; P.001 compared to each of the other types of ventricular activation).In patients without bundle branch block, both types of His bundle, but not myocardial, capture preserve ventricular electrical synchrony as measured using UHF-ECG.
- Published
- 2020
43. Malignant ventricular arrhythmias and other complications of untreated accessory pathways : analysis of prevalence and risk factors in over 600 ablation cases
- Author
-
Piotr Weryński, Maciej Pitak, Kamil Fijorek, Danuta Czarnecka, Marek Jastrzębski, and Paweł Moskal
- Subjects
medicine.medical_specialty ,business.industry ,Atrial fibrillation ,Odds ratio ,medicine.disease ,Sudden death ,Atrioventricular reentrant tachycardia ,Accessory Atrioventricular Bundle ,Sudden cardiac death ,Electrocardiography ,Risk Factors ,Heart failure ,Internal medicine ,Ventricular fibrillation ,Catheter Ablation ,Prevalence ,cardiovascular system ,Cardiology ,Humans ,Medicine ,Risk factor ,Child ,Cardiology and Cardiovascular Medicine ,business ,Retrospective Studies - Abstract
Background The presence of accessory pathways (APs) is a risk factor for sudden cardiac death and other clinical complications. Aims We aimed to characterize all adverse events likely related to the presence of APs in patients referred for AP ablation and to identify risk factors for malignant arrhythmias. Methods We performed a retrospective analysis of consecutive patients referred for AP ablation from 2002 to 2017. Electrocardiograms, electrophysiological system records, and hospital discharge notes were reviewed. We collected data concerning symptoms before ablation, occurrence of ventricular fibrillation or malignant atrial fibrillation (AF), as well as other complications related to APs. Results We identified 602 patients with APs. Serious AP‑related events were observed in 41 patients, including 14 sudden cardiac arrests (1 death) and 16 pre–cardiac arrest events. Other complications included strokes, pulmonary edema, heart failure, and unnecessary device implantation. The risk of malignant arrhythmias decreased with a longer shortest preexcited RR interval (per 10 ms: odds ratio [OR], 1.3; 95% CI, 1.16–1.47) and increased with age (per 10 years: OR, 1.29; 95% CI, 1.06–1.57). The presence of inducible AF, but not sole atrioventricular reentrant tachycardia, increased the risk for malignant arrhythmias when compared with patients without any inducible arrhythmias. Conclusions Patients with APs referred for ablation commonly present with various adverse events. The predictive value of clinical risk factors for malignant arrhythmias is too low to prevent devastating consequences. When high safety and efficacy of AP ablation are ensured, even a low risk of sudden death is unacceptable and a lower threshold for prophylactic ablation should be used to prevent AP‑related adverse events.
- Published
- 2020
44. Cardiac resynchronization therapy-induced acute shortening of QRS duration predicts long-term mortality only in patients with left bundle branch block
- Author
-
Tomasz Sondej, Marek Jastrzębski, Danuta Czarnecka, Kamil Fijorek, Roksana Kisiel, Adrian Baranchuk, and Piotr Kukla
- Subjects
Male ,Bundle of His ,medicine.medical_specialty ,Time Factors ,medicine.medical_treatment ,Bundle-Branch Block ,Cardiac resynchronization therapy ,Action Potentials ,030204 cardiovascular system & hematology ,Risk Assessment ,Ventricular Function, Left ,Cardiac Resynchronization Therapy ,03 medical and health sciences ,QRS complex ,0302 clinical medicine ,Heart Rate ,Risk Factors ,Physiology (medical) ,Internal medicine ,Heart rate ,medicine ,Humans ,cardiovascular diseases ,030212 general & internal medicine ,Aged ,Retrospective Studies ,Aged, 80 and over ,Heart transplantation ,Left bundle branch block ,Surrogate endpoint ,business.industry ,Hazard ratio ,Middle Aged ,medicine.disease ,Treatment Outcome ,Heart failure ,Ventricular Function, Right ,cardiovascular system ,Cardiology ,Female ,Electrophysiologic Techniques, Cardiac ,Cardiology and Cardiovascular Medicine ,business ,circulatory and respiratory physiology - Abstract
Aims QRS narrowing with initiation of biventricular pacing might be an acute electrocardiographic indicator of correction of left bundle branch block (LBBB)-induced depolarization delay and asynchrony. However, its impact on prognosis remains controversial, especially in non-LBBB patients. Our goal was to evaluate the impact of QRS narrowing on long-term mortality and morbidity in a large cohort of patients undergoing cardiac resynchronization therapy (CRT) with different pre-implantation QRS types: LBBB, non-LBBB, and permanent right ventricular pacing. Methods and results This study included consecutive patients who underwent CRT device implantation. Study endpoints: death from any cause or urgent heart transplantation and death from any cause/urgent heart transplantation or hospital admission for heart failure. All pre- and post-implantation electrocardiograms were analysed using digital callipers, high-amplitude augmentation, 100 mm/s paper speed, and global QRS duration measurement method. A total of 552 CRT patients entered the survival analysis. During the 9 years observation period, 232 (42.0%) and 292 (52.9%) patients met primary and secondary endpoints, respectively. QRS narrowing predicted survival in the Kaplan-Meier analysis only in patients with LBBB. Multivariate Cox regression model showed that QRS narrowing was the major determinant of both study endpoints, with hazard ratios of 0.46 and 0.43, respectively. There was a strong relationship between mortality risk and shortening/widening of the QRS, albeit only in the LBBB group. Patients with non-LBBB morphologies had unfavourable prognosis similar to that in LBBB patients without QRS narrowing. Conclusion Acute QRS narrowing in patients with LBBB might be a desirable endpoint of CRT device implantation.
- Published
- 2018
45. CHADS2 and CHA2DS2-VASc scores as tools for long-term mortality prognosis in patients with typical atrial flutter after catheter ablation
- Author
-
Marek Jastrzębski, Jakub Stec, Danuta Czarnecka, Christopher Pavlinec, and Kamil Fijorek
- Subjects
Male ,medicine.medical_specialty ,medicine.medical_treatment ,Population ,Catheter ablation ,030204 cardiovascular system & hematology ,Risk Assessment ,03 medical and health sciences ,0302 clinical medicine ,Predictive Value of Tests ,Risk Factors ,Internal medicine ,Typical atrial flutter ,Atrial Fibrillation ,medicine ,Humans ,education ,Stroke ,Survival analysis ,Retrospective Studies ,education.field_of_study ,business.industry ,Mortality rate ,Hazard ratio ,Atrial fibrillation ,Middle Aged ,medicine.disease ,Prognosis ,Atrial Flutter ,Catheter Ablation ,Female ,Cardiology and Cardiovascular Medicine ,business - Abstract
Background: The CHADS2 and CHA2DS2-VASc scores were shown to predict mortality in patients with atrial fibrillation. However, pathophysiology and treatment outcomes of atrial fibrillation and typical atrial flutter (AFL) differ. Consequently, the prognosis of patients with AFL can also be different. Aims: The aim of the study was to assess CHADS2 and CHA2DS2‑VASc scores as mortality predictors in patients with typical AFL. Methods: Large cohort of consecutive patients with typical AFL who underwent catheter ablation was retrospectively analyzed. The CHADS2 and CHA2DS2‑VASc were calculated using hospital record data. All-cause mortality data was obtained from the registry of national personal identification numbers. The Kaplan–Meier method and multivariable Cox proportional hazard models were applied for survival and hazard ratio analyses, respectively. Results: A total of 469 patients hospitalized for typical AFL ablation were enrolled (mean [SD] age, 63.7 [12.2] years; male sex, 69.1%). Patients were followed from 2 to 12 years resulting in 2974 patient‑years of follow‑up. The Kaplan–Meier survival analysis revealed a negative impact of each component of the CHADS2 and CHA2DS2‑VASc scores on survival with the exception of stroke (not significant) and female sex (related to abetter survival). Consequently, higher scores were predictive of higher all‑cause mortality rates (2.7%–54% at 10 years); the CHA2DS2‑VASc score was equally predictive as the CHADS2 score. Conclusions: In patients referred for typical AFL ablation, the CHADS2 score can be applied for prognostic assessment. A successful AFL ablation procedure should not divert the attention from recognizing and addressing other medical issues that have an impact on long‑term mortality, which remains very high in this population of patients.
- Published
- 2019
46. His bundle capture proximal to the site of bundle branch block: A novel pitfall of the para-Hisian pacing maneuver
- Author
-
Danuta Czarnecka, Piotr Kukla, and Marek Jastrzębski
- Subjects
Bundle branch block ,business.industry ,para-Hisian pacing ,Case Report ,his bundle ,Accessory pathway ,Anatomy ,030204 cardiovascular system & hematology ,medicine.disease ,03 medical and health sciences ,0302 clinical medicine ,Bundle ,RC666-701 ,bundle branch block ,Medicine ,Para-Hisian pacing ,Diseases of the circulatory (Cardiovascular) system ,030212 general & internal medicine ,accessory pathway ,His bundle ,Cardiology and Cardiovascular Medicine ,business - Abstract
The para-Hisian pacing maneuver is useful in determining whether retrograde conduction is dependent on atrioventricular (AV) nodal conduction. Loss of direct His bundle capture results in a longer route for the depolarization wave to reach the AV node and the atrium, as it has to travel through the working myocardium to engage the distal Purkinje fibers. Thus, loss of direct His bundle capture results in obligatory ventriculoatrial (VA) interval prolongation unless a nonphysiological retrograde conduction route (an accessory pathway [AP]) is present. Consequently, a stable VA interval with loss of His bundle capture is considered diagnostic of the presence of an AP. This concept has been regarded as useful, especially when concentric retrograde atrial activation is present.1 Subsequently, however, potential important pitfalls in the interpretation of this differentiating maneuver were described. These include the recognition of inadvertent atrial capture, pure His bundle capture, the presence of fasciculoventricular pathways, and the impact of retrograde dual AV nodal physiology
- Published
- 2018
47. Rate‐related block during permanent His bundle pacing
- Author
-
Weijian Huang, Danuta Czarnecka, Paweł Moskal, Lan Su, Anna Krakowiak, and Marek Jastrzębski
- Subjects
business.industry ,Physiology (medical) ,Block (telecommunications) ,Bundle ,Medicine ,Electrical conduction system of the heart ,Cardiology and Cardiovascular Medicine ,Topology ,business - Published
- 2019
48. Left bundle branch pacing as an alternative modality after His bundle lead removal
- Author
-
Marek Jastrzębski, Artur Oręziak, Maciej Sterliński, Rafał Baranowski, and Joanna Zakrzewska-Koperska
- Subjects
Bundle of His ,medicine.medical_specialty ,Modality (human–computer interaction) ,business.industry ,Bundle-Branch Block ,Cardiac Pacing, Artificial ,Electrocardiography ,Text mining ,Heart Conduction System ,Internal medicine ,Bundle ,Left bundle branch ,medicine ,Cardiology ,Humans ,Cardiology and Cardiovascular Medicine ,business ,Lead (electronics) - Published
- 2020
49. 'Selective' or 'exclusive' His bundle capture
- Author
-
Marek Jastrzębski and Karol Curila
- Subjects
Bundle of His ,business.industry ,Physiology (medical) ,Bundle ,Cardiac Pacing, Artificial ,Humans ,Medicine ,Electrophysiologic Techniques, Cardiac ,Cardiology and Cardiovascular Medicine ,business ,Neuroscience - Published
- 2021
50. Deep septal deployment of a thin, lumenless pacing lead: a translational cadaver simulation study
- Author
-
Danuta Czarnecka, Marcin Strona, Paweł Moskal, Mateusz K. Hołda, Marek Jastrzębski, Agnieszka Bednarek, and Grzegorz Kiełbasa
- Subjects
medicine.medical_specialty ,Ventricular Septum ,030204 cardiovascular system & hematology ,Bundle of His ,03 medical and health sciences ,0302 clinical medicine ,Heart Conduction System ,Cadaver ,Physiology (medical) ,Internal medicine ,Left bundle branch ,medicine ,Humans ,030212 general & internal medicine ,Interventricular septum ,Tip position ,business.industry ,Cardiac Pacing, Artificial ,Depth of penetration ,Bundle branches ,Cadaver model ,medicine.anatomical_structure ,Cardiology ,Cardiology and Cardiovascular Medicine ,business ,Endocardium - Abstract
Aims The recently introduced technique of direct transseptal pacing of the left bundle branch is poorly characterized with many questions with regard to the optimal implantation strategy and safety concerns largely left unanswered. We developed a cadaver model for deep septal lead deployment in order to investigate the depth of penetration in relation to lead behaviour, lead tip position, and the number of rotations. Methods and results Five fresh human hearts and five lumenless, 4.1-Fr pacing leads were used for deep septal deployment simulations. The leads were positioned with the use of a dedicated delivery sheath and screwed into the interventricular septum at several sites progressively more distal from the atrioventricular ring with a predetermined number of lead rotations. During each lead deployment, the depth of tip penetration was measured and the lead behaviour was noted. Four distinct lead behaviours were observed: (i) helix only penetration, no matter how many rotations were performed, due to the ‘endocardial entanglement effect’ (43.1% cases) or (ii) ‘endocardial barrier effect’ (19.6% cases), (iii) shallow/moderate penetration, with ensuing ‘drill effect’ when more rotations were added (9.8% cases), and (iv) deep progressive penetration with each additional rotation, occurring when the ‘screwdriver effect’ was present (27.4% cases, including three septal perforations). These different lead behaviours seemed to be determined by the lead position—mainly the strength of the initial endocardial layer—and the number of fully transmitted rotations. Conclusion New insights into deep septal lead deployment technique were gained with regard to safe and successful implantation.
- Published
- 2019
Catalog
Discovery Service for Jio Institute Digital Library
For full access to our library's resources, please sign in.