1. [Application of a new solid adsorbent tube for the determination of three kinds of epoxy eompounds in air].
- Author
-
Rong WF, Ling WJ, Wu BH, Ruan XL, Hu JW, Meng RB, and He JH
- Subjects
- Air, Chromatography, Gas, Methylene Chloride, Workplace, Air Pollutants, Occupational analysis
- Abstract
Objective: To develop a new solid sorbent tube for simultaneously capturing ethylene oxide (EO) , propylene oxide (PO) and epichlorohydrin (ECH) in air, and establish a complete set of method. Methods: In June 2018, EO, PO and ECH in air were captured by the new solid sorbent tube filled with carbon aerogel adsorbent, desorbed with solution of 5% ( V/V ) methanol-methylene chloride, separated through capillary chromatographic column, and then analyzed by gas chromatography-flame ionization detector. Results: The linear ranges of EO, PO and ECH were 0.24-960.00, 0.60-2384.00 and 0.12-472.40 mg/L respectively, and the related coefficients were between 0.99995-0.99997. The relative standard deviations ( RSD ) within the group were 1.66%-4.09%, 1.36%-4.43%, and 1.99%-5.65%, respectively, and the RSD between the group were 2.69%-4.95%, 2.77%-5.30%, and 3.27%-6.67%, respectively. The average desorption efficiencies were 88.25%-94.50%, 98.17%-98.60%, and 97.79%-101.04%, respectively. The samples could be stored at 4 ℃ refrigerator for at least 27 days. Conclusion: The newly developed solid sorbent tube filled with carbon aerogel adsorbent and its complete set of gas chromatography method could be used for sampling and quantitative detection of EO, PO and ECH in workplace air.
- Published
- 2020
- Full Text
- View/download PDF