1. Use of International Adaptive Thermal Comfort Models as a Strategy for Adjusting the Museum Environments of the Mudejar Pavilion, Seville.
- Author
-
Gallego-Maya, Inmaculada and Rubio-Bellido, Carlos
- Subjects
- *
PRESERVATION of architecture , *THERMAL comfort , *CONSERVATION & restoration , *OFFICE buildings , *MUSEUM buildings - Abstract
Adaptive thermal comfort models are increasingly utilized to condition thermal environments by considering occupants' adaptability. The most widely recognized models internationally are the ASHRAE 55-2020 and UNE-EN 16798-1:2020 standards, primarily applied in residential and office buildings. However, their use in heritage buildings such as museums has been very limited. These environments present unique challenges that complicate the implementation of conventional energy-saving methodologies due to restrictions on interventions in the buildings to safeguard their historical value. Therefore, it is essential to develop research that evaluates the applicability of these standards as an alternative strategy to the specific conditions of museums in heritage buildings in Spain. This study aims to explore the application of the international adaptive thermal comfort models of the ASHRAE 55-2020 and UNE-EN 16798-1:2020 standards in parallel with the preventive conservation conditions of the collections established by the UNE-EN 15757:2011 standard. The aim is to evaluate new strategies for environmental reconditioning to improve visitor comfort while ensuring the conservation of the collections in the exhibition spaces of the Museum of Popular Arts and Customs, housed in a 1914 building known as the Mudejar Pavilion in Seville. Field monitoring was conducted to assess the thermal environment and visitor comfort. The results revealed that the monitored environmental conditions of the exhibition spaces of the Mudejar Pavilion, in accordance with ASHRAE 55-2020 standards, showed high effectiveness in ensuring thermal comfort for visitors, achieving comfort 99% of the time annually, with an acceptability of 80%. High suitability for the conservation of collections was also observed, with optimal conditions achieved 87% of the time. However, under the standards of UNE-EN 15757:2011 for a Category III expectation level, comfort was only achieved 70% of the year, while stability of conservation conditions was achieved 88% of the time. Finally, the implementation of specific correction guidelines is proposed to achieve the acceptability limits of greater energy efficiency. [ABSTRACT FROM AUTHOR]
- Published
- 2024
- Full Text
- View/download PDF