Back to Search Start Over

Using APCS for Plasma Vertical Control at TCV.

Authors :
Cruz, N.
Moret, J.-M.
Coda, S.
Paley, J. I.
Duval, B. P.
Rodrigues, A. P.
Piras, F.
Felici, F.
Correia, C. M. B. A.
Varandas, C. A. F.
Source :
IEEE Transactions on Nuclear Science. 8/2/2011 Part 1 Part 1, Vol. 58 Issue 4, p1570-1575. 6p.
Publication Year :
2011

Abstract

Early tokamaks with circular cross-section plasmas were vertically stable in nature and no problems were reported on the control of the vertical position. However, the concept of vertically elongated plasma cross-section, with benefits to the energy confinement time, led to vertical instabilities. To overcome this problem, complex closed feedback loop control systems with a vertical position measurement, signal processing, control algorithm, power supplies and active actuating coils are used. [ABSTRACT FROM PUBLISHER]

Details

Language :
English
ISSN :
00189499
Volume :
58
Issue :
4
Database :
Academic Search Index
Journal :
IEEE Transactions on Nuclear Science
Publication Type :
Academic Journal
Accession number :
64345108
Full Text :
https://doi.org/10.1109/TNS.2011.2160203