Back to Search Start Over

Differential impact on post-transplant outcomes between pulsatile- and continuous-flow left ventricular assist devices.

Authors :
Ventura, Pere A.
Alharethi, Rami
Budge, Deborah
Reid, Bruce B.
Horne, Benjamin D.
Mason, Nathan O.
Stoker, Sandi
Caine, William T.
Rasmusson, Brad
Doty, John
Clayson, Stephen E.
Kfoury, Abdallah G.
Source :
Clinical Transplantation. July/August 2011, Vol. 25 Issue 4, pE390-E395. 6p. 3 Charts, 2 Graphs.
Publication Year :
2011

Abstract

Ventura PA, Alharethi R, Budge D, Reid BB, Horne BD, Mason NO, Stoker S, Caine WT, Rasmusson B, Doty J, Clayson SE, Kfoury AG. Differential impact on post-transplant outcomes between pulsatile- and continuous-flow left ventricular assist devices. Clin Transplant 2011: 25: E390-E395. © 2011 John Wiley & Sons A/S. Abstract: Background: The HeartMate II (HMII) left ventricular assist device (LVAD) has proven reliable and durable and has become the preferred choice for bridge to transplant therapy (BTT) when compared with the pulsatile HeartMate XVE (XVE). In this study, we compared the post-transplant (PTx) outcomes between XVE and HMII using a large national data registry. Methods: The Organ Procurement and Transplantation Network (OPTN)/United Network for Organ Sharing (UNOS) Thoracic Registry database was queried for all patients implanted with either an XVE or an HMII as BTT during 2004-2009. Statistical analysis between XVE and HMII were performed using Kaplan-Meier survival analysis and Cox regression analyses. Results: A total of 673 patients were implanted with the XVE and 484 with HMII. When adjusted for age, gender, ethnicity, intra-aortic balloon pump, ventilator, inotropes, dialysis, body mass index, creatinine, bilirubin, transfusion, pulmonary capillary wedge, and pulmonary arterial pressures, the HMII had similar one- and three-yr survival (hazard ratio = 0.95, CI = 0.64, 1.42) and rejection-free survival PTx compared to XVE. The XVE group had more early incidences of allograft rejection (AR) and hospitalization for infection (HI). Conclusions: Compared to XVE, patients with HMII have similar one- and three-yr survival after heart transplantation with less risk of early graft rejection and significant infection. With a strong shift toward use of continuous-flow LVADs, PTx outcomes are expected to continue to improve. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09020063
Volume :
25
Issue :
4
Database :
Academic Search Index
Journal :
Clinical Transplantation
Publication Type :
Academic Journal
Accession number :
92971052
Full Text :
https://doi.org/10.1111/j.1399-0012.2011.01433.x