Charged particle flows in the beam extraction region of a negative ion source for NBI.

Authors :
Geng S
Tsumori K
Nakano H
Kisaki M
Ikeda K
Osakabe M
Nagaoka K
Takeiri Y
Shibuya M
Kaneko O
Source :
The Review of scientific instruments [Rev Sci Instrum] 2016 Feb; Vol. 87 (2), pp. 02B103.
Publication Year :
2016

Abstract

Experiments by a four-pin probe and photodetachment technique were carried out to investigate the charged particle flows in the beam extraction region of a negative hydrogen ion source for neutral beam injector. Electron and positive ion flows were obtained from the polar distribution of the probe saturation current. Negative hydrogen ion flow velocity and temperature were obtained by comparing the recovery times of the photodetachment signals at opposite probe tips. Electron and positive ions flows are dominated by crossed field drift and ambipolar diffusion. Negative hydrogen ion temperature is evaluated to be 0.12 eV.