1. Gas exchange efficiency slopes to assess exercise tolerance in chronic obstructive pulmonary disease
- Author
-
Hiromi Yanagi, Keisuke Miki, Kazumi Koyama, Satoshi Miyamoto, Yasuhiro Mihashi, Yuka Nagata, Kazuki Hashimoto, Hisako Hashimoto, Mari Fukai, Tomonori Maekura, Rika Yonezawa, Shizuka Sakaguchi, Takuro Nii, Takanori Matsuki, Kazuyuki Tsujino, and Hiroshi Kida
- Subjects
Oxygen ,Carbon dioxide ,Exercise tolerance ,Gas exchange ,Pulmonary rehabilitation ,Ventilatory efficiency ,Diseases of the respiratory system ,RC705-779 - Abstract
Abstract Background In patients with chronic obstructive pulmonary disease (COPD), the clinical use of the minute ventilation-carbon dioxide production ( $$\rm{\dot V}$$ E- $$\rm{\dot V}$$ CO2) slope has been reported as a measure of exercise efficiency, but the oxygen uptake efficiency slope (OUES), i.e., the slope of oxygen uptake ( $$\rm{\dot V}$$ O2) versus the logarithmically transformed $$\rm{\dot V}$$ E, has rarely been reported. Methods We hypothesized that the $$\rm{\dot V}$$ E- $$\rm{\dot V}$$ CO2 slope is more useful than OUES in clinical use for the pathophysiological evaluation of COPD. Then, we investigated the cardiopulmonary exercise testing parameters affecting each of these slopes in 122 patients with all Global Initiative for Chronic Obstructive Lung Disease (GOLD) COPD grades selected from our database. Results Compared with the GOLD I-II group (n = 51), peak $$\rm{\dot V}$$ O2 (p
- Published
- 2024
- Full Text