1. A novel procedure of puncture to access the pulmonary venous atrium in complex congenital heart disease with surgical correction
- Author
-
Hisashi Sugiyama, Seiji Asagai, Kouta Taniguchi, Keiko Toyohara, and Kei Inai
- Subjects
Adult ,Heart Defects, Congenital ,medicine.medical_specialty ,Vena Cava, Superior ,Adolescent ,medicine.medical_treatment ,Catheter ablation ,Punctures ,030204 cardiovascular system & hematology ,Balloon ,Young Adult ,03 medical and health sciences ,0302 clinical medicine ,Internal medicine ,medicine ,Humans ,Heart Atria ,030212 general & internal medicine ,Atrium (heart) ,Child ,Vein ,Mustard procedure ,Surgical repair ,Supraventricular arrhythmia ,business.industry ,Surgical correction ,Surgery ,Treatment Outcome ,medicine.anatomical_structure ,Pulmonary Veins ,Catheter Ablation ,Cardiology ,Cardiology and Cardiovascular Medicine ,business - Abstract
Background In complex congenital heart disease, supraventricular arrhythmia develops long term after surgical repair. The arrhythmia could have pharmacological tolerance and sometimes be fatal. We report our experiences with puncturing tough or calcified surgical repair material to access the pulmonary venous atrium for the purpose of the management of arrhythmia in complex congenital heart disease with surgical correction. Methods From June 2016, subsequent 9 patients underwent the procedure. Their age at the procedure ranged from 11 to 43 years old (median 26.4 years old). Surgical procedures were Mustard procedure (XenomedicaⓇ) in 6, lateral tunnel total cavo-pulmonary connection with autologous pericardium in 2, and extra-cardiac total cavo-pulmonary connection with expanded polytetrafluoroethylene (ePTFE) tube in 1. Results Multi-planar reconstruction imaging by cardiac computed tomography was done for making plans before the procedures. Under intracardiac echocardiography guidance, an 8 French steerable sheath was perpendicularly adjusted to target objects. The sharpened edge of 0.014 inch guide wire penetrated with gentle forward force. Subsequently, the puncture site was dilated from a small balloon to a large one step by step. In all patients, penetration was successfully completed. Catheter ablation was achieved in 8 patients and a pacemaker was implanted through the re-canalized superior caval vein in 1 patient. No complications were recorded. Conclusion The trans-catheter puncture of the synthetic or calcified material is safe and feasible, although careful planning is required with imaging. A steerable sheath could easily be controlled to the make appropriate angle to the target object for preventing slippage and conveying effective force.
- Published
- 2021